F-63
F-63
TROUBLESHOOTING & REPAIR
SQUARE WAVE TIG 355
CH1
0 volts
2 ms
20 volts
SCOPE SETTINGS
Volts/Div.....................20V/Div.
Horizontal Sweep.....2 ms/Div.
Coupling ............................DC
Trigger .........................Internal
MACHINE LOADED TO 350 AMPS
AT 34VAC
This is a typical AC output voltage
waveform generated from a properly
operating machine. Note that each
vertical division represents 20 volts
and that each horizontal division rep-
resents 2 milliseconds in time. The
machine was loaded with a resis-
tance grid bank. The TIG 355 display
read 350 amps at 34 VAC.
Note: Scope probes connected at
machine output terminals: (+) probe
to electrode terminal, (-) probe to
work terminal.
AC TIG MODE (BALANCED WAVEFORM)
HIGH VOLTAGE / HIGH FREQUENCY can damage test equipment.
• Perform all voltage and waveform checks with high frequency circuit OFF.
CAUTION
8/98