Impinger II – Advantage Digital Service Manual - Domestic
2
SEQUENCE OF OPERATION
IMPINGER II ADVANTAGE
SERIAL NUMBER 2038616 AND ABOVE
(OVENS WITH PUSH BUTTON CONTROLS)
MODEL 1116-000-A
NAT. GAS
120VAC
60 HZ. 1 PHASE
MODEL 1117-000-A
LP GAS
120VAC
60 HZ. 1 PHASE
POWER SUPPLY
Electrical power is supplied to the oven by a three-conductor cordset. Voltage
from the black conductor to the white conductor is 120VAC.
Black conductor is hot
White conductor is neutral.
Green conductor is ground.
CONTROL BOX AUTO
COOL DOWN
When the temperature in the control box reaches 120
°
F
±
3
°
(48.9
°
C
±
1.7
°
),
the cooling fan thermostat will switch power to the control box cooling fan. The
thermostat will interrupt power to the cooling fan when the control box
temperature falls to 100
°
F
±
3
°
(37.8
°
C
±
1.7
°
).
MAIN FAN CIRCUIT
Power is permanently supplied, through a 10 amp fuse, and through a normally
closed control box hi-limit thermostat, to the normally open main power switch.
Power is also supplied to the normally open cooling fan thermostat. Closing the
main power switch supplies 120VAC to the main fan motor, the cooling fan
motor, the primary of the control transformer, the conveyor motor and to the
ignition control.
BURNER CIRCUIT
Closing the main power switch supplies 120VAC to the burner blower motor.
120VAC is also supplied, through the normally closed oven cavity hi-limit
thermostat, the main fan centrifugal switch (this switch closes when the main
fan reaches approx. 1600 RPM), to the primary of the burner transformer.
IGNITION CONTROL
The ignition control operates on both 24VAC and 120VAC. When the control is
energized by 24VAC from the transformer, 120VAC is switched by the ignition
control to the hot surface igniter for 45 seconds for the hot surface igniter warm
up. The igniter glows red, 24VAC is switched to the gas valve, which opens,
and ignition should now occur.
TEMPERATURE CONTROL
Closing the main power switch supplies 120VAC to the primary of the oven
control transformer. Secondary voltage, 24VAC, is supplied to the oven control.
The oven control is set to desired temperature. The thermocouple will provide
varying millivolts to the oven control. The oven control supplies 120VAC to the
temperature regulation valve at intermittent intervals to maintain the desired
temperature. The display on the oven control will indicate when the temperature
regulation valve is energized.
NOTE: The display also indicates oven temperature
CONVEYOR DRIVE
Closing the main power switch supplies 120VAC to the conveyor motor and to
the primary of the control transformer. Secondary voltage, 24VAC, is supplied to
the oven control. Setting the oven control to the desired time outputs voltage,
through a reversing switch, to the conveyor motor.
NOTE: The conveyor system uses a hall effect sensor and magnet to prove
operation of the conveyor motor. If the conveyor motor is not running, “BELT
JAM” is indicated on the display.
Summary of Contents for 1116-000-A
Page 23: ...Impinger II Advantage Digital Service Manual Domestic 23 ...
Page 25: ...Impinger II Advantage Digital Service Manual Domestic 25 ...
Page 27: ...Impinger II Advantage Digital Service Manual Domestic 27 ...
Page 29: ...Impinger II Advantage Digital Service Manual Domestic 29 ...
Page 31: ...Impinger II Advantage Digital Service Manual Domestic 31 ...
Page 32: ...Impinger II Advantage Digital Service Manual Domestic 32 ...