background image

Form 402373 

TROUBLE

CAUSE

REMEDY

Meter not accurate

Flowrate not correct

Adjust flowrate to correct rate (1-30 Ltr/min)

No fluid passing through 

a) Blocked strainer

a) Clean or replace strainer

the meter

b) Dirt particles jamming the rotors

b) Dismantle meter assembly and clean
     ( refer to meter disassembly )

c) Damaged plunger seal (8)

c) Replace damaged plunger seal

 The meter is not registering fluid output

a) Damaged register assembly (22)

a) Replace register assembly

b) Damaged gear or gears 

b) Relpace complete gear set.

     ( 24,25,26,27)

Constant oil leak from the nozzle

Damaged plunger seal (8)

Replace plunger seal ( check for damage )

Intermittent drip from the nozzle

Dirt in the nozzle

Remove the nozzle and blow out any dirt particles, 
replace if necessary.

Oil leak from the lever assembly area

Damaged o’rings (12)

Replace damaged o’rings

Low flow rate

Blocked swivel strainer 

Replace strainer 

Oil leaking from the swivel inlet

Damaged o’ring or swivel

Replace swivel  

TROUBLE SHOOTING GUIDE 

TECHNICAL SPECIFICATIONS 

Wetted components: 

Accuracy: 

Flow Range: 

Max. working pressure: 

Operating temperature: 

Acetal, aluminium, nitrile (NBR), mild steel 

+/- 1% 

0.26-8 US gal/min (1-30 litres/minute ) 

1500 psi / 103.5 Bar 

½

” BSPT or NPT (F) 

14°F (-10°C) to 131°F (+55°C) 

Weight (approx): 

 2.8lbs (1.3kg ) 

Inlet Thread 

Summary of Contents for 908MFG

Page 1: ...return the unit to your nearest authorized service center Never point the nozzle at yourself or anyone else Never exceed the pressure rating of any component in stalled in the System Before attempting any repairs or maintenance of this pro duct firstly disconnect the air supply from the oil pump then release the oil line pressure by squeezing the lever on your oil control gun ASSEMBLY Before every...

Page 2: ...ody casting 12 B Insert the valve stem 11 valve body assembly 10 and spring 9 into the body casting 12 Note Refer to Fig for correct orientation of cam shaft 13 and valve stem 11 C Assemble the spring retainer circlip 8 D Carefully assemble the lever 17 to the cam shaft 13 Note Press the lever to ensure the correct operation of F Assemble the quad ring 7 and the back swivel bushing 6 so the solid ...

Page 3: ...e rotors 2 Lightly grease the o ring 31 and place it on the meter body 3 Clean the meter cover plate 32 and place it on the body Take care not to damage the o ring 31 The Rotor with Magnets 4 Install the 8 screws 33 and tighten in a diagonal pattern to 0 73 ft lb 1nm Visual check the cap has been pulled down evenly 5 Test the meter by turning the rotors with a finger or by applying low air pressur...

Page 4: ...tant oil leak from the nozzle Damaged plunger seal 8 Replace plunger seal check for damage Intermittent drip from the nozzle Dirt in the nozzle Remove the nozzle and blow out any dirt particles replace if necessary Oil leak from the lever assembly area Damaged o rings 12 Replace damaged o rings Low flow rate Blocked swivel strainer Replace strainer Oil leaking from the swivel inlet Damaged o ring ...

Page 5: ... not apply to you This warranty gives you specific legal rights You may also have other rights that vary by jurisdiction Customers not located in the Western Hemisphere or East Asia Please contact Lincoln GmbH Co KG Walldorf Germany for your warranty rights Lincoln Industrial Special Limited Warranties SPECIAL LIMITED 2 YEAR WARRANTY SL V Series Single Injectors 85772 85782 and Replacement Injecto...

Reviews: