CONNECTING THE LN-7 TO THE
CV-655 (TERMINAL STRIP)
1.
Set the CV-655 POWER toggle switch to the OFF
(0) position.
2.
Disconnect main AC input power to the CV 655.
3.
Connect the wire feeder control cable leads to the
CV-655 terminal strip as shown in Figure C.3.
4.
Connect the wire feeder control cable ground lead
to the frame terminal marked .
NOTE: The CV-655 must be properly grounded.
5.
PERFORM THIS STEP ONLY IF THE LN-7 IS
EQUIPPED WITH A METER KIT.
Extend wire feeder control cable lead #21 so it can
be connected directly to the work piece.
a. Make a bolted connection using AWG #14 or
larger insulated wire. Tape the bolted connec-
tion with insulating tape.
NOTE: If the work cable length is less than 25 feet
and the connections to the work piece are
secure, then wire feeder control cable lead
#21 can be connected directly to the CV-
655 terminal strip.
b. An S-16586-X remote voltage sensing work
lead is available for this purpose.
c. Keep the #21 lead electrically separate from
the work cable circuit and connection.
d. Tape the #21 lead to work cable for ease of
use.
NOTE: The connection diagram shown in Figure
C.3 shows the electrode connected for
positive polarity. To change polarity:
a. Set the CV-655 POWER toggle switch to the
OFF (0) position.
b. Move the electrode cable to the negative (-)
output terminal.
c. Move the work cable to the positive (+) output
terminal (High inductance or low inductance
as needed).
d. Connect control cable lead #21 to “+21” on
the terminal strip.