The dimensions of the work area to consider will depend on the construction of the area and other activities that are
taking place.
Consider the following guidelines to reduce electromagnetic emissions from the machine.
•
Connect the machine to the input supply according to this manual. If disturbances occur if may be necessary to take
additional precautions such as filtering the input supply.
•
The output cables should be kept as short as possible and should be positioned together. If possible connect the
work piece to ground in order to reduce the electromagnetic emissions. The operator must check that connecting
the work piece to ground does not cause problems or unsafe operating conditions for personnel and equipment.
•
Shielding of cables in the work area can reduce electromagnetic emissions. This may be necessary for special
applications.
WARNING
The Class A equipment is not intended for use in residential locations where the electrical power is provided by the public
low-voltage supply system. There may be potential difficulties in ensuring electromagnetic compatibility in those
locations, due to conducted as well as radiated disturbances.
WARNING
This equipment complies with IEC 61000-3-12 provided that the short-circuit power S
sc
is greater than or equal to:
POWERTEC 305C PRO:
S
sc
≥
1,9MVA
POWERTEC 355C PRO:
S
sc
≥
2,2MVA
POWERTEC 425C PRO:
S
sc
≥
2,9MVA
at the interface point between the user’s supply and the public system. It is the responsibility of the installer or user of
the equipment to ensure, by consultation with the distribution network operator if necessary, that the equipment is
connected only to a supply with a short circuit power S
sc
greater than or equal to data on the table above.
Technical Specifications
POWERTEC 305C, 355C & 425C PRO:
INPUT
Input Power at Rated Output
EMC Group / Class
305C PRO:
13.5 kVA @ 40% Duty Cycle
II / A
355C PRO:
17.5 kVA @ 40% Duty Cycle
II / A
Input Voltage
230 / 400V
±
10%
Three Phase
425C PRO:
22.8 kVA @ 40% Duty Cycle
II / A
Frequency
50/60 Hz
RATED OUTPUT AT 40°C
Duty Cycle
(
Based on a 10 min. period
)
Output Current
Output Voltage
305C PRO:
40%
60%
100%
280A
230A
175A
28.0 Vdc
25.5 Vdc
22.8 Vdc
355C PRO:
40%
60%
100%
350A
285A
220A
31.5 Vdc
28.2 Vdc
25.0 Vdc
425C PRO:
40%
60%
100%
420A
345A
265A
35.0 Vdc
31.3 Vdc
27.3 Vdc
OUTPUT RANGE
Welding Current Range
Maximum Open Circuit Voltage
305C PRO:
30A - 280A
305C PRO:
46 Vdc
355C PRO:
30A - 350A
355C PRO:
46 Vdc
425C PRO:
30A - 420A
425C PRO:
52 Vdc
RECOMMENDED INPUT CABLE AND FUSE SIZES
Fuse or Circuit Breaker Size
Input Power Cable
305C PRO:
32A (for 230V) Superlag
20A (for 400V) Superlag
305C PRO:
4 Conductor, 4mm
2
355C PRO:
40A (for 230V) Superlag
25A (for 400V) Superlag
355C PRO:
4 Conductor, 4mm
2
425C PRO:
50A (for 230V) Superlag
32A (for 400V) Superlag
425C PRO:
4 Conductor, 6mm
2