Operating mode
Important:
The operating mode is accesible only during the
pause time and cannot be operated during the running time
(pump operating time).
Precondition: When the voltage supply is applied, the
segment (On/h) is lit.
Operating option: Trigger an additional lube cycle
* Press this key. The pause time already elapsed is reset.
The operating time starts. A circulating segment is
visible on the display during the whole operating time.
Operating option: Read information on how to set the pau-
se time and remaining pause time.
* Press this key.
Note: The following display sequence is shown
twice
and
is cancelled after 60 seconds. The change of display occurs
every two seconds. Example:
PP = 12h 30min
rP = 5 h 10 min
PP
(set pause time)
12 .
(hours)
. 30
(minutes)
rP
(remaining pause time)
5 .
(hours)
. 10
(minutes)
occurs after second sequence
Display
Press
after 2 sec.
after 2 sec.
after 2 sec.
after 2 sec.
after 2 sec.
after 60 sec.