Subject
to
change
without
notice
Owner Manual
Operating Instructions
2.1A-30004-A02
LINCOLN GmbH & Co. KG Postfach 1263 D-69183 Walldorf Tel +49 (6227) 33-0 Fax +49 (6227) 33-259
Page 9 of 36
Mode of Operation of Pump 233
The electric motor drives the eccentric (1, fig. 7, 8).
During the operating time:
- piston 2 sucks in lubricant from the reservoir, see fig. 7.
- piston 2 dispenses the lubricant to the connected
lubrication points via the metering devices, see fig. 8.
The following designs are available:
Piston diameter, K5 ..................................................... 5 mm
Lubricant output....................................... approx. 2 cm³/min
Piston diameter, K6 (Standard) .................................. 6 mm
Lubricant output.................................... approx. 2.8 cm³/min
Piston diameter, K7 ..................................................... 7 mm
Lubricant output....................................... approx. 4 cm³/min
Tightening torque............................................25 Nm
Fig. 6 - Pump element, sectional drawing
1 - Piston
2 - Return spring
3 - Check valve
1003a95
Fig. 7 - The pump element sucks in lubricant.
1 - Eccentric
3 - Spring
2 - Piston
4 - Check valve
Pump elements with fixed lubricant output
Suction Phase
20002068
1 - Eccentric
3 - Spring
2 - Piston
4 - Check valve
Förderphase
Fig. 8 - The pump element dispenses lubricant
1004a95