3.3.
CONFIGURATIONS
For the detailed technical data, the production and the mechanical drawings, cfr. annexed.
TECHNICAL DATA
ART.
2700
FIXED
HEAD
TIP
UP
HEAD
FIXED
BOWL
REMOVABLE
BOWL
ROUNDED
BOWL
EDGE
FLAT
EDGE
BOWL
EDGE
SPIRAL
TOOL
SPATULA
TOOL
FIXED
TOOL
INTERCHANGEABLE
TOOL
UNIQUE
MOTOR
FOR
BOWL
AND
TOOL
A
MOTOR
FOR
BOWL
AND
ONE
FOR
TOOL
ELECTROMECHANICAL
CONTROLS
ELECTRONIC
CONTROLS
WITH
STOP
DELAY
TIMER
ELECTRONIC
CONTROLS
WITH
TIMER
FOR
SPEED
SWITCHING
3.4.
SERVICE CONDITIONS
DATA
ART- 2700
Level of acoustic power continue equivalent weighted A
Minor of 70dBA
Current nature – Frequency
Cfr. machine plate
Current full charge value
Cfr. machine plate
Use nominal voltage
Cfr. machine plate
Allowable presumed current of nominal short circuit
conditioned
6 kA symmetric
Mass and neutral
TT e TN
Protection degree
IP X3
Machine positioning
Work bench used in the food field
of height included
between
900/1100mm
from the trampling floor of
adequate capacity, in which it is possible to circulate freely
around the machine with a free space of at least
800mm
Use place
Inside
Maximum temperature of the work environment air
+40°C
Requested minimum lighting
500 lux
Further use conditions
Inadequate
machine for functioning in environments
where there are contaminated agents: for example
powders, acids, corrosive gas, salts and similar.
Inadequate
machine for functioning in environments
where there are potentially explosive atmospheres
classified as zone 0 or zone 1 or zone 2.
Inadequate
machine for functioning in environments
where there are ionized and not ionized radiations: for
example microwaves, ultraviolet rays, lasers, X rays and
similar.
Inadequate
electric equipment to be equipped with
machines or to function in environments where there are
vibrations and shocks: in contrary case assembly it far
from the device and foresee antivibrating supports
PROTECTION DEVICE RECOMMENDED AGAINST THE OVERCURRENTS
Insulation nominal voltage
Ui = > 690 V
Nominal current
In = > see electric diagram
Magnetic relay setting
Im = < see electric diagram
Thermal relay setting
Ir = see electric diagram
Maximum value of the damage ring impedance
0.1
Ω
Service@linda-lewis.co.uk
0161 696 0052
www.linda-lewis.co.uk