14/21
Linde AG, Linde Gas Deutschland ©
Fig. 8 – Gas fitting
F1
Gas Cylinder
F2
Cylinder Valve
F3
Gas heater connector
F4
Pressure Reducer
F5
High Pressure Manometer
F6
Low Pressure Manometer
F7
Adjusting Screw
F8
Gas outlet
F9
Solenoid Valve
F10
Chain
1. Place the gas cylinder on the platform and fix it properly by the fixing
chain. We recommend using bolts and nuts to fix it more safely.
2. Connect the pressure reduction valve on the gas cylinder.
3. Connect the gas hose to gas outlet
F8
on the valve and the gas inlet
F9
on the machine.
4. In case you use gas CO2 it may be needed to use suitable gas heater
(only above 6 l/min). Connect the heater to the
F3
heater connector
(optional). Use type corresponding to voltage and current given on the
shield.
5. Open the
F2
cylinder valve.
6. Press the torch trigger.
7. Adjust the amount of gas on the reduction gas valve (it is not a part of the
welding machine) by the
F7
adjusting screw.
8. Release the torch trigger.
8.
WELDING
For orientating adjusting of the welding current and voltage you can use
empirical relation U2 = 14+0,05 2. From that you can specify desired voltage.