problem
cause
how to fix it
The soda water does not flow.
Pressure at the inlet has exceeded
3.0 bar.
Reduce the pressure on the water
valve min. to 2.5 Bar.-max 3.0 Bar.
No water supply to the water tap.
Open the valve on the water tap.
Inlet of pressure of CO2 is not
open.
Open and check the inlet pressu-
re CO2 on the cylinder and adjust
the pressure of CO2 min. to 4.0 Bar
-max. 5.0 Bar.
Restart the machine by switching
off the switch and then switching it
back on or unplugging the
power cord 230V.
Again reconnect!
Water filter blocked.
Check or replace the water filter.
The beverage is chilled only a little. Wrong setting of the thermostat.
Turn the thermostat knob
clockwise to No. 7
Bad air circulation.
Make sure the condenser plate are
not clogged.
The machine overheats.
Place the machine to a cooler
surroundings.
The tap twitches, drink spurths
out.
The high pressure on the chilled
beverage is too high.
Reduce the pressure.
The fittings do not seal properly.
Poorly inserted tube.
Pull out the tube, check to see if
there are not any sharp edges,
possibly shorten with knife.
Scratches on the hose.
Pull out and shorten for about
2cm.