2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: support@lindsaybb.com
7
|
P a g e
LB-1000-EDFA
User Manual
on the fiber cable and connector with a fiber inspecting microscope. Ensure the fiber
optic connectors and jumper cables are clean.
6)
Ensure optical jumper connectors are matched properly to the device adapters. (i.e.
SC/APC to SC/APC). Using mismatched connectors will damage the connectors and
degrade system performance. Ensure that each fiber has a matching connector.
7)
Use an optical power meter to verify that the optical input power level to the EDFA is
within the specification (-6 to +10dBm for this EDFA). You can now connect the Optical
fiber to the OPT IN connector on the front panel.
8)
Also, you can now connect the Optical fiber to the
OPT OUT
connector on the front
panel. Use an optical power meter to verify that the optical output power level is within
the specification.
9)
Using the touch screen or web interface via LB-1000-CM the operating parameters for
the application module can be monitored and adjusted. Operating parameters and
adjustments on the LB-1000-EDFA are explained in Section 5.0.