background image

 

LBDG-250-DC-8200-1 

 

3.2 Installation Diagrams 

 
    Strand Mount   

 

 

 

Strand Mount 

     

 

 

    

 

 

   with Hanger Brackets 

 

          

 

 
 

 

3.3 Power Requirements 
 

The  DOCSIS  3.1  Gateway  can  be  connected  to  any  power-passing 
coupler  or  splitter.  The  following  formula  can  be  used  to  calculate  the 
current draw for your installat ion: 
 
 

Where: 

 
 

 

 

 

 

 

 

I  

= Current draw in Amps 

 

I  =  12 + (1.39 * P)   

 

V  

= Line Voltage in Volts  

 

                  

 

 

 

= Total output power 
   draw in W atts    

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 

Summary of Contents for LBDG-250-DC-8200-1

Page 1: ...LBDG 250 DC 8200 1 LBDG 250 DC 8200 1 Strand Mount DOCSIS 3 1 Gateway With DC Power Output Installation Guide...

Page 2: ...chments not recommended for this product as they may cause hazards SERVICING Remove power from this device and refer servicing to qualified personnel under the following conditions 1 If the inside of...

Page 3: ...has used replacement parts specified by the manufacturer or parts that have the same characteristics as the original part Unauthorized substitutions may result in fire electric shock or other hazards...

Page 4: ...ovide component identification diagrams installation instructions and specifications 1 2 General Description This DOCSIS 3 1 Gateway uses the HFC network to power and backhaul IP based devices It can...

Page 5: ...ately 406 x 228 x 165mm 16 x 9 x 6 5 not including connectors Its weight is around 5 1 Kg 11 2 Lbs 1 4 Major Components Internally the housing bottom contains the HFC interface board and DOCSIS 3 1 ca...

Page 6: ...rge protection A power interrupt to disconnect AC power SECTION 2 COMPONENTS IDENTIFICACION HFC INPUT SURGE ARRESTOR AC INTERRUPT WEATHER SEAL UPSTREAM DOWNSTREAM PADS 20dB F CONNECTOR TEST POINT HFC...

Page 7: ...the Lindsay Broadband sales office Pad values can be determined ahead of time The loss of the HFC interface board should be accounted for when calculating pad values There is 4dB of loss in the revers...

Page 8: ...3 3 Power Requirements The DOCSIS 3 1 Gateway can be connected to any power passing coupler or splitter The following formula can be used to calculate the current draw for your installation Where I Cu...

Page 9: ...LBDG 250 DC 8200 1 3 4 Output Receptacle Wiring...

Page 10: ...dem can be measured at the single test point Readings are 20dB below the levels seen at the cable modem Adjust pad values as required 8 Optional Silicone Grease can be applied to the exposed part of t...

Page 11: ...the connector body from the parts kit into the fixed body already installed in the Gateway Keep tightening until the flat washer just starts to compress and bulge outward This can be done by hand or...

Page 12: ...LBDG 250 DC 8200 1 SECTION 4 LBDG 250 DC 8200 1 HOUSING 4 1 Housing Dimensions TOP VIEW RIGHT END SIDE VIEW SIDE VIEW FROM HINGE 16 375 9 750 1 875 6 375 1 250...

Page 13: ...bps 100 meters RJ45 406 x 228 x 165mm 16 x 9 x 6 5 5 1 Kg 11 2 Lbs IP68 15 PSI for 10 Seconds Notes 1 Levels reported by modem management interfaces reference the modem F port Levels at the Gateway KS...

Reviews: