background image

 

 

 

 

Before using this product, please read this manual carefully.  

 

 

 

 

 

 

 

 

 

 

 

       Contents of This Package:

 

 

 

 

 

 

 

 

 

 

 

 

•     LBP-UPS-F Multifunctional UPS 

  Warning

 

 

 

 

 

 

 

 

 

 

       

(Part No. 5-1666)

 

 

Do not use this UPS with any power adaptor other than Lindsay Broadband Part No. 6506-056. 

   

     

AC Power Adaptor   

 

 

A risk of explosion exists if the UPS battery is incorrectly connected or replaced by an incorrect type. 

       

(Part No.

 

6506-056)

       

 

A battery showing signs of swelling, cracking or leaking should be immediately replaced.

 

 

•     1m (3’) Coax Cable with F-Male Connectors 

(Contact Lindsay Broadband if you need a replacement battery.)   

 

 

 

        (Part No. 4008-160) 

 

CAUTION:

 

Contains a Li-Ion Battery Pack. Follow all instructions to avoid risk of fire and burns.

   

•     User Manual (This document)

 

 

 

         Do Not Open, Crush, Heat Above 

50⁰C (122⁰F)

, or Incinerate. 

 

 

 

     

 

 Always recycle batteries in accordance with local regulations.   

                                        

 

 

 

                    

 

 

 

 

 

        Options: 

•     1m (3’) CPE Dual Power Cable      – Part No. 4008-159

       

(F – Male to Dual 5.5 x 2.1mm & 5.5 x 2.5mm Barrel Connectors)

  

 

•     1m (3’) CPE Triple Power Cable    – Part No. 4008-159-1   (F – Male to Triple 5.5 x 2.1mm, 5.5 x 2.5 Barrel Connectors, F – Male Connector) 

•     4.6m (15’) CPE Power Cable          – Part No. 4008-150-1

   

(F – Male to Stripped Pair of #16 AWG Wires [Red + Black])                   

•     Replacement Li-Ion Battery Pack – Part No. 5-1666-RB 

 

            

 

 

 

 

 

                  

 

Product Overview: 

The LBP-UPS-F is an easy to install, Lithium-Ion technology based, standby UPS system. It is designed to continue to deliver regulated, low noise power to any 

12–15 VDC powered CPE device (RFoG, RF amplifier, modem, router, wireless, CCTV etc.) during AC power failures.  

Protection features include: battery charging and safety management, charge/discharge and over/under temperature monitoring, output overload and 

short-circuit protection as well as input over-voltage, surge and reverse polarity protection. Other features include: microprocessor controlled operation,  

manual ON/OFF control, and LEDs that provide status as well as visual fault indications. In the OFF condition, the UPS enters into an ultra-low power state to 

save energy. The AC power adaptor and the LBP-UPS-F incorporate standard female F connectors for use with coax cables. 

 

Operation:

  

Under normal operation with AC power applied, the UPS de15 VDC power to the CPE device from the AC power adaptor and at the same time 

maintains optimal charge of the internal battery.  The Power LED is illuminated 

BLUE

 to indicate normal AC powering.  

When an AC power failure occurs, the UPS d12 VDC battery power to the CPE device with zero transfer time. An 

AMBER

 LED is illuminated to indicate 

backup mode powering. The CPE device will remain powered by the battery until the AC power is restored, at which time the UPS diverts AC converted 

DC power back to the device with zero transfer time (the Power LED is again illuminated 

BLUE

). The UPS has a typical 8-hour run time with a 400mA load. If 

the battery voltage falls below its set minimum value, the UPS shuts down to prevent over-discharge of the battery. A fully discharged battery requires 2 – 3  

days for full recharge.  

To turn the UPS on, press and hold the ON/OFF pushbutton for more than 2 seconds. To turn the UPS off again, repeat the previous process. 

Note: The LBP-UPS-F automatically turns power off to the CPE device when a fault is detected. Power will automatically be restored once the fault condition 

is cleared. 

 

 

   

   

        

 

 

 

 

 

Installation:    

 

 

 

•   

Unpack and inspect the LBP-UPS-F for damage. 

 

 

•   Select a dry, well ventilated mounting location for the LBP-UPS-F.  

     Ensure that an AC power outlet is within a 1m distance.  

•   Using a quantity of 2 self-tapping screws (not supplied), mount the UPS using the mounting slots provided on the unit. 

•   Using the supplied coax cable, connect the AC power adaptor to the LBP-UPS-F IN port. Do not torque the connectors more than 35 in-lbs. 

•   Using an appropriate length of coax, connect the LBP-UPS-F OUT port to the power port of the CPE device (maximum load = 10W). Do not torque the 

     connectors more than 35 in-lbs. 

•       

Always run cables such that they cannot be damaged by being walked on or by objects set on or against them.

 

•   Plug the AC power adaptor into the power outlet. Press and hold the ON/OFF pushbutton for more than 2 seconds. Ensure that the UPS Power LED is 

     illuminated 

BLUE

. The CPE device should now be powered on. 

•   Remove the AC power adaptor from the power outlet. The UPS Power LED should extinguish and the Battery Mode LED should illuminate 

AMBER

. The 

     CPE device should remain powered. 

•   Plug the AC power adaptor into the power outlet and ensure that the UPS returns to normal operation. 

 

LBP-UPS-F Multifunctional UPS for Customer Premise Equipment 

                            User Manual 

①   ON

/OFF Pushbutton  

②   Temperature

 Fault LED  

③   Battery Mode LED

 

④   Power LED

 

⑤   Charge LED

 

⑥   

Power Input F Connector 

⑦   

Power Output F Connector   

   Battery Compartment Door 

⑨   Mounting Slots

 

 

AC Power  

Adaptor 

To CPE 

Device 

 

This unit is designed for an indoor environment, 

protected from moisture. Its operating temperature range is 0⁰C (32⁰F) to 50⁰C (122⁰F).

 

ON/ 

OFF 

Reviews: