Options: 

 

 

 

 

 

 

 

 

Status LEDs:

 

The LBP-UPS-F utilizes 4 LEDs that provide fast and easy indication of the status of the unit at any time. These LEDs also provide visual fault indications to 

provide quick troubleshooting for the technician.  

   

Battery Pack Replacement:

 

 

 

  

 

 

 

Specifications: 

 

 

 

 

15V

DC

 / 1.5A

Standby Mode

V

IN

 = V

OUT

Battery Mode

12V

DC

0.9A / 10W Max.

110%

0 mSec

Typical Run Time

200 / 400 / 800mA

16 / 8 / 4 Hours

Over / Under Temperature Monitor

Overcharge, Overdischarge

Output Short Overload

Input Over-Voltage

Input Reverse Polarity

6KV Input Surge

Battery Charging

0 - 45

⁰C  (32 - 113°F)

V

OUT

50⁰C  (122°F)  Max.

IN/OUT Connectors

SCTE 02

F - Female

78 x 156 x 44 mm  (3.1 x 6.1 x 1.7 Inches)

0.45 Kg  (1.0 Lb)

UL2054, UN38.3  (Power Bank Safety)

UL60950-1  (Information Technology Equipment Safety)

IEEE 587 (C62-41-1991) Cat B3 6KV  (Surge Withstand)

Complies With FCC 47 CFR Part 15, Class B  (RF Emissions)

UPS Protection

Operating Temperature

Dimensions
Weight

Certifications/Approvals

* Note 

1

   Lindsay Part No. 6506-056  100-240V

RMS

 AC To DC Switching Regulated Wall Adaptor

Input Power Source 

1

Output Voltage

Output Current/Power
Overload Protection
Output Transfer Time

Li-Ion Protection

Lindsay Broadband Inc.   |   2-2035 Fisher Drive, Peterborough, ON  K9J 6X6  Canada   |   Tel: 1.705.742.1350 

Information in this document is subject to change without notice. 

Rev. 11/18  (LBB0100) 

 

Press and hold the ON/OFF pushbutton for more 

than 2 seconds to turn the UPS off. 

 

Remove 2 screws from Battery Compartment Door. 

 

Slide Battery Compartment Door to the right and 

remove. 

 

Unplug the Li-Ion battery pack and remove. 

 

Plug the replacement Li-Ion battery pack into the 

UPS connector and place the pack into its 

compartment. 

 

Replace the Battery Compartment Door and the 2 

screws removed previously. 

 

 

    

 

    

  

           

 

 

 Always recycle batteries in accordance with local regulations.

 

Three optional CPE powering cables are available from Lindsay Broadband:  

• 1m (3’) long Part No. 4008-159 allows easy connection from the LBP-UPS-F to CPE devices that accept either 

   5.5mm x 2.1mm or 5.5mm x 2.5mm barrel power connectors rather than an F connection 

   (modems, routers, wireless devices etc.). The cable has a male F connector at the UPS end and a 

   Y terminated in both 5.5mm x 2.1mm and 5.5mm x 2.5mm barrel power connectors at the CPE 

   end. Simply plug the appropriate connector into the CPE power port. 

• 1m (3’) long Part No. 4008-159-1 is the same but also includes an F connection at the CPE end. 

• 4.6m (15’) long Part No. 4008-150-1 has a male F connector at the UPS end and a stripped pair of #16 AWG 

   wires [Red + Black] at the CPE end. 

Contact Lindsay Broadband for the optional CPE powering cables. 

 