Options:
Status LEDs:
The LBP-UPS-F utilizes 4 LEDs that provide fast and easy indication of the status of the unit at any time. These LEDs also provide visual fault indications to
provide quick troubleshooting for the technician.
Battery Pack Replacement:
Specifications:
15V
DC
/ 1.5A
Standby Mode
V
IN
= V
OUT
Battery Mode
12V
DC
0.9A / 10W Max.
110%
0 mSec
Typical Run Time
200 / 400 / 800mA
16 / 8 / 4 Hours
Over / Under Temperature Monitor
Overcharge, Overdischarge
Output Short Overload
Input Over-Voltage
Input Reverse Polarity
6KV Input Surge
Battery Charging
0 - 45
⁰C (32 - 113°F)
V
OUT
50⁰C (122°F) Max.
IN/OUT Connectors
SCTE 02
F - Female
78 x 156 x 44 mm (3.1 x 6.1 x 1.7 Inches)
0.45 Kg (1.0 Lb)
UL2054, UN38.3 (Power Bank Safety)
UL60950-1 (Information Technology Equipment Safety)
IEEE 587 (C62-41-1991) Cat B3 6KV (Surge Withstand)
Complies With FCC 47 CFR Part 15, Class B (RF Emissions)
UPS Protection
Operating Temperature
Dimensions
Weight
Certifications/Approvals
* Note
1
Lindsay Part No. 6506-056 100-240V
RMS
AC To DC Switching Regulated Wall Adaptor
Input Power Source
1
Output Voltage
Output Current/Power
Overload Protection
Output Transfer Time
Li-Ion Protection
Lindsay Broadband Inc. | 2-2035 Fisher Drive, Peterborough, ON K9J 6X6 Canada | Tel: 1.705.742.1350
Information in this document is subject to change without notice.
Rev. 11/18 (LBB0100)
•
Press and hold the ON/OFF pushbutton for more
than 2 seconds to turn the UPS off.
•
Remove 2 screws from Battery Compartment Door.
•
Slide Battery Compartment Door to the right and
remove.
•
Unplug the Li-Ion battery pack and remove.
•
Plug the replacement Li-Ion battery pack into the
UPS connector and place the pack into its
compartment.
•
Replace the Battery Compartment Door and the 2
screws removed previously.
Always recycle batteries in accordance with local regulations.
Three optional CPE powering cables are available from Lindsay Broadband:
• 1m (3’) long Part No. 4008-159 allows easy connection from the LBP-UPS-F to CPE devices that accept either
5.5mm x 2.1mm or 5.5mm x 2.5mm barrel power connectors rather than an F connection
(modems, routers, wireless devices etc.). The cable has a male F connector at the UPS end and a
Y terminated in both 5.5mm x 2.1mm and 5.5mm x 2.5mm barrel power connectors at the CPE
end. Simply plug the appropriate connector into the CPE power port.
• 1m (3’) long Part No. 4008-159-1 is the same but also includes an F connection at the CPE end.
• 4.6m (15’) long Part No. 4008-150-1 has a male F connector at the UPS end and a stripped pair of #16 AWG
wires [Red + Black] at the CPE end.
Contact Lindsay Broadband for the optional CPE powering cables.
ON/
OFF
UPS Function
LED Color
LED Status
All LEDs
ON / OFF KEY Press > 2 sec to turn ON / OFF