background image

Section 5                                                                         IP Access Configuration & Operation

 

34 

 

Note: 

Your local keyboard changes its keyboard layout according to the remote host system. If 

you use a  German administration system and your host system uses a US English keyboard 

layout  for  instance,  some  special  keys  on  the  German  keyboard  will  not  work  as  expected. 

Instead, the keys will result in their US English counterpart. You can circumvent such problems 

by adjusting the keyboard of your remote system to the same mapping as your local one. 

 

The Remote Console window always tries to show the remote screen with its optimal size. That 

means  it  will  adapt  its  size  to  the  size  of  the  remote  screen  initially  and  after  the  screen 

resolution  of  the  remote  screen  has  been  changed.  However,  you  can  always  resize  the 

Remote Console window in your local window system as usual. 

 

Remote Console Control Bar

 

The upper part of the Remote Console window contains a control bar. Using its elements you 

can see the state of the Remote Console and influence the local Remote Console settings. A 

description for each control follows. 

 

 

Ctrl+Alt+Delete 

Sends the ‘Control Alt Delete’ key combination to the remote system  

 

  

Auto Adjust button 

If  the  video  display  is  poor  quality  or  distorted  in  some  way,  click  this  button  and  wait  a  few 

seconds while the U8/16-IP tries to adjust itself for the best possible video quality. 

 

 

  Sync mouse 

Activates  the  mouse  synchronization  process.  Choose  this  option  in  order  to  synchronize  the 

local AND remote mouse cursors. This is especially necessary when using accelerated mouse 

settings on the host system. In general, there is no need to change mouse settings on the host. 

 

 

 Single/Double mouse mode 

Switches between the Single Mouse Mode (where only the remote mouse pointer is visible) and 

the  Double  Mouse  Mode  (where  remote  and  local  mouse  pointers  are  visible)  Single  mouse 

mode is only available if using SUN JVM 1.3 or higher. 

 

 

Tip:

  When  in  single  mouse  mode  use  the  hotkey  combination

 

[ALT]  +  [F12]

 

to  release 

mouse control and access the menus etc. 

 

Section 5                                                                         IP Access Configuration & Operation

 

35 

 

 

Options 

Opens the Options menu. A short description of the each of the options follows: 

 

Monitor Only 

Toggles  the  ‘Monitor  only’  filter  on  or  off.  If  the  filter  is  switched  on,  no  remote  console 

interaction is possible but monitoring is. 

 

Exclusive Access 

If a user has the appropriate permission, he can force the Remote Consoles of all other users to 

close. No one can open the Remote Console at the same time again until this user disables the 

exclusive access, or logs off. 

 

A change in the access mode is also visible in the status line indicated by this icon.  

 

Scaling 

Allows  you  to  scale  down  the  Remote  Console.  You  can  still  use  both  mouse  and  keyboard; 

however the scaling algorithm will not preserve all display details. 

 

Mouse Handling 

The submenu for mouse handling offers two options for synchronizing the local and the remote 

mouse pointer. 

 

Fast Sync 

The fast synchronization is used to correct a temporary, but fixed skew. 

 

Intelligent Sync  

Use  this  option  if  the  fast  sync  does  not  work  or  the  mouse  settings  have 

been changed on the host system 

 

 

 

 

 

 

Local Cursor 

Offers a list of different cursor shapes to choose from for the local mouse pointer. The selected 

shape will be saved for the current user and activated the next time this user opens the Remote 

Console. The number of available shapes depends on the Java Virtual Machine; a version of 

1.2 or higher offers the full list. 

 

Video Settings 

Opens  a  panel  for  changing  the  U8/16-IP  video  settings.  The  U8/16-IP  features  two  different 

dialogs, which influence the video settings: 

 

Video Settings in the KVM section in the front end menu: 

 

The  Noise  Filter  option  defines  how  the  U8/16-IP  reacts  to  small  changes  in  the  video  input 

signal. A large filter setting needs less network traffic and leads to a faster video display, but 

small  changes  in  some  display  regions  may  not  be  recognized  immediately.  A  small  filter 

displays  all  changes  instantly  but  may  lead  to  a  constant  amount  of  network  traffic  even  if 

display content is not really changing (depending on the quality of the video input signal). All in 

all the default setting should be suitable for most situations. 

 

Note: 

This method takes more time than fast sync and requires a correctly 

adjusted picture. Use the auto adjustment function or the manual correction in 

the Video Settings panel to setup the picture.

 

Summary of Contents for 32530

Page 1: ...he required optional IP or Cat 5 access modules can be purchased separately and are simply installed into the back of a U8 16 Modular KVM Switch This manual also covers the KVM Switch U8 16 C another...

Page 2: ...witch Operation 13 3 2 Keyboard Hotkey Selection 15 3 3 On Screen Display Menu OSD Port Selection 17 Section 4 19 4 1 Cat 5 KVM Extender Features 20 4 2 Cat 5 KVM Extender Installation 20 4 3 Cat 5 KV...

Page 3: ...6 IP Local Console Remote Access Remote local control of multiple computers Section 1 Introducing the U8 16 IP 5 The U8 16 IP provides a non intrusive solution for remote access and control because th...

Page 4: ...ically restored when switching between computers LED Display for easy status monitoring Buzzer sound for port switching confirmation Uses special single connector USB PS 2 VGA KVM cables with 15 Way H...

Page 5: ...or the attached computer is not switched on Shift Button This button allows ports 9 to 16 to be selected Bank Select Button Pressing this button switches banks and allows the computers connected to sl...

Page 6: ...to the console ports of the U8 16 MASTER KVM Switch Step 2 Connect the first Slave Use the daisy chain cable to connect the daisy chain port of the MASTER previous KVM Switch and the other end to the...

Page 7: ...itch without having to power it off as long as it is currently not connected to the console In most cases the PS 2 mouse and keyboard signals will be maintained and will not be lost b The mouse driver...

Page 8: ...the keyboard is in hotkey mode If you have not pressed any key in hotkey mode within 2 seconds the keyboard will return back to Operating System control status For the U series KVM switches it is pos...

Page 9: ...your password a STATUS OSD display will be displayed System 02 102 Bank 1 Port 02 System PC name Scroll Lock recent hotkey 02 selected port Auto LOGOUT function During normal operation if no input fro...

Page 10: ...users and their passwords For both up to 8 characters can be used Select 05 ACCESS LIST for Supervisor only to assign access restrictions to users for certain ports Default setting is no access restr...

Page 11: ...ing the dedicated KVM system cable included with the Cat 5 KVM Extender Finally connect the Cat 5 5e 6 cable and the power supply unit The KVM cable provided can be used to connect either PS 2 or USB...

Page 12: ...U processing time Transporting large amounts of data over TCP IP requires a high bandwidth connection Limited bandwidth may restrict or limit the possible screen resolutions and colour depths which ca...

Page 13: ...Type config and press the Enter key Wait a few seconds for the configuration information to appear As you proceed the following questions will appear on the screen To accept the default values shown i...

Page 14: ...o the keyboard settings Remote Mouse Settings A common problem with KVM devices is the synchronization between the local and remote mouse cursors The U8 16 IP addresses this problem with an intelligen...

Page 15: ...Mode where only the remote mouse pointer is visible Activate this mode in the open Remote Console and click into the window area The local mouse pointer will be hidden and the remote one can be contro...

Page 16: ...e host system using a securely encrypted connection you need a browser that supports the HTTPS protocol Strong security is only assured by using a key length of 128 Bit Some older browsers do not have...

Page 17: ...that runs over this connection is neither HTTP nor HTTPS but RFB Remote Frame Buffer Protocol RFB needs to establish a connection to port number 443 Your local network environment has to allow this c...

Page 18: ...menu A short description of the each of the options follows Monitor Only Toggles the Monitor only filter on or off If the filter is switched on no remote console interaction is possible but monitoring...

Page 19: ...es Reset all settings to the factory made defaults Save Changes Save changes permanently Section 5 IP Access Configuration Operation 37 Undo Changes Restore last settings Soft Keyboard Opens up the su...

Page 20: ...oding is enabled a value in brackets displays the compressed transfer rate For more information about Monitor Only and Exclusive Access settings see the relevant sections on page 35 Section 5 IP Acces...

Page 21: ...t interface is entirely controlled with the appropriate functions of the web interface Once you have successfully logged into the U8 16 IP a command line will be presented and you can enter management...

Page 22: ...output in the specified output file tmp floppy image Adjust both parameters exactly to your needs input device etc Section 5 IP Access Configuration Operation 43 Windows Windows users should use the t...

Page 23: ...our hard disk For example with Nero choose Copy and Backup Then navigate to the Copy Disc section Select the CD ROM or DVD drive you would like to create an image from Specify the filename of the imag...

Page 24: ...SAMBA SAMBA must be set up properly You may either edit the SAMBA configuration file etc samba smb conf or use the Samba Web Administration Tool SWAT or WebMin to set the correct parameters Section 5...

Page 25: ...tion 49 1 Choose the drive you wish to redirect from the drop down list Enter your user name and password and click OK 2 Access the host computer from the Remote Console window You will see that the r...

Page 26: ...r account has only the permission to open and use the Remote Console The default password for both accounts is pass Ensure you change the passwords as soon as you have installed and accessed the U8 16...

Page 27: ...timized adjustment of compression and colour depth for the indicated network speed Section 5 IP Access Configuration Operation 53 Manually Allows adjustment of both compression rate and colour depth i...

Page 28: ...ly catching this keystroke already Typical examples are Control Alt Delete in Windows and DOS which is always caught or Control Backspace on Linux for terminating the X Server The syntax to define a n...

Page 29: ...nput signal A large filter setting needs less network traffic and leads to a faster video display but small changes in some display regions may not be recognized immediately A small filter displays al...

Page 30: ...ion The maximum network traffic generated through the U8 16 IP s Ethernet device Value in Kbit s Enable Telnet access Set this option to allow access to ARA express using the Telnet Gateway see the Se...

Page 31: ...rver Check time The U8 16 IP registers itself in the Dynamic DNS server at this time Check interval This is the interval for reporting again to the Dynamic DNS server by the U8 16 IP Section 5 IP Acce...

Page 32: ...n machine with the Download CSR button see the illustration on the next page 2 Send the saved CSR to a CA for certification You will get the new certificate from the CA after a more or less complicate...

Page 33: ...needs to be connected to the serial interface of the U8 16 IP Connecting to the U8 16 IP using a telephone line allows you to set up a dedicated point to point connection from your console computer to...

Page 34: ...virtually every IP address is possible but you must make sure it is not interfering with the IP settings of the U8 16 IP switch and your console computer The default value will work in most cases Pas...

Page 35: ...and is available after the U8 16 IP has been started If the U8 16 IP loses power or a hard reset is performed all logging data will be lost To avoid this use one of the log methods described below Se...

Page 36: ...ser s its IP address from which host the user comes from and its activity status is displayed RC means that the Remote Console is open If the Remote Console is opened in exclusive mode the term exclus...

Page 37: ...the appearance of the web interface is correct To do this in Internet Explorer select Tools Internet Options General Delete Files Tick the check box Delete all offline content and click OK Tip Should...

Page 38: ...guarantee that the U8 16 IP will work with all known mice especially those developed and produced after the U8 16 IP s introduction Avoid moving the mouse or pressing the mouse buttons when switching...

Page 39: ...F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 PRINTSCREEN SCROLL LOCK BREAK INSERT HOME PAGE UP DELETE END PAGE DOWN UP LEFT DOWN RIGHT NUM LOCK NUMPAD0 NUMPAD1 NUMPAD2 NUMPAD3 NUMPAD4 NUMPAD5 NUMPAD6 NUMPAD...

Page 40: ...pour le recyclage de tout quipement lectrique et lectronique Chaque Etat membre de l Union Europ enne a mis en application la nouvelle r glementation WEEE de mani res l g rement diff rentes Veuillez...