background image

 

   English Manual   

 

 

       -5- 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

English Manual                                             -4- 

 

Operation 

 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

English Manual                                            -3- 

 
 

 

 

Private Mode  

                                                                              

For security reasons, ONLY 

CONSOLE 1 

has the privilege to 

access the computer and disables CONSOLE 2 From seeinghis 
operations. To do so, the DIP switch number 3 must be set to ON 
before the 39121 is turned on. This user may access the computer 
in the Private mode by pressing the 

right `SHIFT

` six times.    The 

Private mode continues till:                                                              
a.   the first user presses the 

right `SHIFT

 `key six times, or         

b.   any user presses the 

MANUAL 

button. 

Screen Save  Function                                                       

To protect the screen phosphors, when the 39121 is in Auto 
Mode and noone is accessing the computer, a "stripe" image 
can scrol ldown the screen. To enable this function, set DIP 
Switch 4 to the On position before turning on the 39121.

  

Specifications 

Function  

39121  

Number of Users   

2  

Shared Functions   

Keyboard, Monitor, Mouse  

2 Console Selected  

LEDs  

1 Manual Status  

Function Keys   

Automatic / Manual Selection  

Timeout Setting   

5 - 90 Seconds  

Keyboard Connectors   

3 Mini DIN-6 Female (Input/Output) 

1 DB-9 Female (Input)  

Serial Mouse Connectors  

2 DB-9 Male (Output)  

PS/2 Mouse Connectors    3 Mini DIN-6 Female (Input/Output) 

VGA Connectors   

3 High Density DB-15 (Input/Output)  

Enclosure   

Metal & Plastic  

Weight   

2650g  

Dimensions (L x W x H)    254 x 180 x 82 (mm)  

 
 
 

Preventing Radio & TV Interference 

WARNING!!!

 This equipment generates, uses, and can 

radiate radio frequency energy and if not installed and 
used in accordance with the instruction manual, may 
cause interference to radio communications. It has been 
tested and found to comply with the limits for a Class A 
computing device pursuant to Subpart J of Part 15 of FCC 
Rules, which are designed to provide reasonable 
protection against such interference when operated in a 
commercial environment. Operation of this equipment in a 
residential area is likely to cause interference in which 
case the user at his own expense will be required to take 
whatever measures may be required to correct the 
interference. 

 

Limited Warranty 

IN NO EVENT SHALL THE DIRECT VENDOR S 
LIABILITY EXCEED THE PRICE PAID FOR THE 
PRODUCT FORM DIRECT, INDIRECT, SPECIAL, 
INCIDENTAL, OR CONSEQUENTIAL DAMAGES 
RESULTING FROM THE USE OF THE PRODUCT, 
DISK, OR ITS DOCUMENTATION. 

The direct vendor makes no warranty or representation, 
expressed, implied, or statutory with respect to the 
contents or use of this documentation, and specially 
disclaims its quality, performance, merchantability, or 
fitness for any particular purpose. 

The direct vendor also reserves the right to revise or 
update device or documentation without obligation to 
notify any individual or entity of such revisions, or 
update. For further inquires please contact your direct 
vendor. 

 
 
 
 

                                                                    

  LINDY Art. Nr. 39121 

 

 

© LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH  -  DAPR 2000 

 

Operation 

Auto Mode                                                                                  

Auto Mode operates according to the following rules:                     
1.       When the 39121 is turned on it comes up in Auto Mode, and          
operates on a first-come-first-served basis. Both Console LEDs are 
On; the Manual LED is Off.                                                              
2.       The first user to strike his keyboard has access to the 
computer. As soon as this occurs: 

 

 

              

-The 39121, locks on to his console; during the time that he is    
locked on, the other user can not access the computer;                      
-The Console LED that corresponds to his console turns On;             
-The Console LED for the other console turns Off.                          
3.       If the user who has access does not strike his keyboard or 
move his mouse before the 

Timeout Period

 (set with DIP    

Switches 1 and 2), elapses:                                                                                 
- The 39121  unlocks from his console;  

                              

- The 39121 switches to Auto Mode;                                                 
- Both Console LEDs turn On (indicating that either console may   
access the computer);                                                                          
-The Manual LED is Off                                                                   
4.       A user may terminate his access by either hitting the 

Left 

Shift Key

 six times to switch the 39121 back to Auto Mode, or by 

pressing the 

Manual Button

 to select the other console. 

Manual Mode                                                                   

     

Manual Mode is used to access the computer for a long 
period of time. It is invoked by repeated pressing of the 
Manual Button until the Console LED for the des                                               

Note: 

Pressing the Manual Button causes the 39121 to cycle to 

the next choice:

                                                                           

Auto Mode --> Console 1 --> Consolel 2 --> Auto Mode

        

When Manual Mode is invoked, the 39121 locks onto the selected 
console and prohibits the other console from accessing the 
computer. The lock-on remains in effect until the Manual Button is 
pressed again. 

 

 

 

 

 

Reviews: