RS-232 PORT CONNECTIONS
The AM/II RS-232 port can be used to connect to a serial input
line printer, a personal computer, modem or data terminal.
Printer Connections
☞
NOTE: The installation of a printer is optional. The AM/II may
be used without a printer if activity logging is not required.
The AM/II can connect to virtually any standard personal
computer printer that accepts a 9600 baud serial RS-232 input.
Connecting a printer to the AM/II allows for a printed copy of
each transmitter activation showing the transmitter number,
time and date of activation as well as the various system
reports. Use the Model A2P cable to connect the AM/II to a
printer.
Personal computer printers contain switches for setting the
printer’s data format and options. The printer’s switches must
be set correctly to match the output of the AM/II before the
printer will function properly. Refer to the specific printer’s
instruction manual for the location and possible settings of the
printer’s switches.
The printer may have additional options that may or may not
be useful with the AM/II.
The printer options that must be set are:
✶
Baud Rate 9600
✶
8 Data Bits
✶
No Parity
✶
1 Stop Bit
✶
No Auto Line Feed after Carriage Return
✶
X-ON/X-OFF Data Flow Control
2
3
7
20
8-PIN
2
1
8
6
RD
TD
GND
CTS
DB-25
SIGNAL
TD
RD
GND
DTR
SIGNAL
AM/II
PRINTER
MALE
DB-25
8-PIN
MODULAR
PIN 1
A2P CABLE
RADIO
DECODE
ACCESS GRANTED
READER KEYPAD
ACCESS OUT DATA
ACCESS IN DATA
ACCESS A
ACCESS B
ACCESS C
OBSTACLE
MAGIC WAND
ACCESS D
B
O
1
O
1
O
1
B
O
1
N.O. COM. N.C.
N.O. COM. N.C. N.O. COM. N.C. N.O. COM. N.C.
EARTH
GROUND
ACCESS OUT
KEYPAD IN
CHANNEL A
CHANNEL B
CHANNEL C
CHANNEL D
READER IN
14 - 24 VAC
12 - 35 VDC
AC POWER
INPUT
DC POWER
INPUT
NETWORK
OFF
ON
POWER
RESET
DISPLAY
CONTRAST
MEMORY EXPANSION CARD
MEDIUM (64 K)
SMALL (16 K)
LARGE (128 K)
X-LARGE (256 K)
WARNING
TURN THE POWER SWITCH OFF BEFORE INSTALLING OR
REMOVING THIS MEMORY EXPANSION CARD
SEVERE
ELECTRICAL
DAMAGE
MODEL A2C
CABLE
SAMPLE REAL-TIME EVENT PRINTOUT
10:52:42 06/20/95 0:0 sTx[00001] ->{A}
AM/II Unit #1
10:52:42 06/20/95 0:2 Crd[01470] ->{D}
Front Door Card Reader
10:54:14 06/20/95 0:0 sTx[00003] ->{A}
AM/II Unit #1
10:54:21 06/20/95 0:1 Kpd[2003] ->{C}
Front Gate Keypad
10:54:28 06/20/95 0:0 sTx[00002] ->{A}
AM/II Unit #1
REAL-TIME EVENT LOG PRINTS EACH
EVENT AS IT HAPPENS
TOP LINE OF EVENT SHOWS:
TIME & DATE
NETWORK ADDRESS : REMOTE DEVICE ADDRESS
MEDIA TYPE & ID#
DIRECTION OF ENTRY & RELAY LETTER
Event Log Report Jun 22, 1995 09:56:39 Page 001
Installation: South Hills Apartments AM/II Unit #1
08:55:35 06/22/95 0:0 sTx[00003] ->{B}
Unit #1
08:51:21 06/22/95 0:2 Crd[01470] ->{B}
Front Door Card Reader
08:45:49 06/22/95 0:0 sTx[00001] ->{A}
Unit #1
12:28:42 06/20/95 0:0 Obs[1] Obstacle Txmtr Trouble
11:02:42 06/20/95 0:0 Exit Program Mode
11:02:42 06/20/95 0:0 Program Mode Timed Out
SAMPLE STORED EVENT LOG
STORED EVENT LOG SHOWS ALL
EVENTS FROM MOST RECENT TO
OLDEST STORED EVENT
BOTTOM LINE OF EVENT SHOWS:
DEVICE NAME
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8
SEND
DATA
RECIEVE
DATA
REQUEST
TO SEND
N/C
N/C
CLEAR
TO SEND
N/C
GROUND
8-PIN MODULAR
PLUG PINOUT