AREA 26
CONFIGURE ACCESS OUT
Area 26 is used to setup the access out terminals when
connecting the AM/II to an external access control system.
The access out format, data mode, facility code and button
offset can be programmed in this area.
Each of the following activities are performed in programming
Area 26. From the main menu, use [
⇑
], [
⇓
] or enter “26” on the
keypad to scroll to “Access Out Format, Enter Program
Area 26” and press [OK]. Press [
*
] when finished to return to
the main menu.
Access Out Application Note
The format of the data that is sent to an external access control
panel through the ACCESS OUT terminals is programmable in
Area 26. Currently the AM/II can send Wiegand26,
SecuraKey31 or Sentex30 format data.
Three different data structures can be selected for each format.
Each selects which data is sent out.
VALIDATION: If this option is selected, data will only get sent
from the ACCESS OUT terminals when media is granted
access by the AM/II. The data sent is the Access Out Facility
Code and the media ID number.
PASS-TXID: If this option is selected, data will always get sent
from the ACCESS OUT terminals when any media is decoded,
regardless if access is granted by the AM/II. The data sent is
the Access Out Facility Code and the media ID number.
PASS-SEQID: If this option is selected, data will always get
sent from the ACCESS OUT terminals when any valid
transmitter is decoded, regardless if access is granted by the
AM/II. The data sent is the Access Out Facility Code and the
transmitter sequence number.
Access Out Setup
☞
NOTE: Refer to the Advanced Programming Bulletin
(P/N 210516) for expanded details on programming the
AM/II to activate other access control panels.
➊
Use [
⇑
] or [
⇓
] to select “Access Out Format”.
➋
Use [
⇐
] or [
⇒
] to select “Off Wiegand26 Sentex30 SecuraKey31” for
the access out data format. Match the format with the type of access
control panel connected to the ACCESS OUT terminals. Press [OK]
when desired selection is blinking.
➌
Unit displays: “Access Out Mode”. Use the [
⇐
] and [
⇒
] keys to select
“Validation Pass-TXID Pass-SEQID” for the Access Out Mode. Press
[OK] when desired selection is blinking. See Advanced Programming
Bulletin for details.
➍
Unit displays: “Access Out Facility Code”. Enter the three-digit facility
code and press [OK]. This code must be the same code as programmed
into the access control panel connected to the ACCESS OUT terminals.
➎
Unit displays: “Access Out Button Offset”. Use the [
⇐
] and [
⇒
] keys
to select “Off On” for the Access Out Button Offset. Select “ON” if
separate buttons on the same transmitter are intended to control two
different devices. Press [OK] when desired selection is blinking.
CONFIGURE ACCESS OUT
AREA 26
26.1
26.2
26.3
26.4
Access Out Mode
Validation Pass-TXID Pass-SEQID
Access Out Facility Code
Facility Code: 00000
Access Out Button Offset
Off On
Access Out Format
Off Wiegand26 Sentex30 SecuraKey31
58