Power
The AERO.ASI is equipped with two power supplies (dual PSUs). Always connect BOTH power in-
lets to clean AC power sources, ideally from separate feeds. Remember, this is primarily to protect you
against unreliable
power sources
, and not from problems with AERO.ASI’s power supplies.
We strongly recommend using an uninterruptible power supply (UPS) on at least one of the AC power
feeds; separate units should be used for each inlet.
Since there is no on/off switch on the AERO.ASI, connect AC power to both inlets to power the unit
on. The blue light behind the Linear Acoustic logo illuminates, the LCD screen shows the Linear
Acoustic logo, and the fans turn on. When the IP address of the unit appears on the LCD screen, start-
up is complete and it is ready to use. This process may take up to two minutes.
To power off, just remove both AC power cords from the unit.