background image

WIRELESS
SECURITY
SYSTEM

Owner’s Manual

Help Line: 1-800-528-4454

FRONT COVER
1 OF 40

EMERGENCY

ensor
tatus
isplay

Featuring:

Defiant S

S

D DF-

16 O

w

ner

’s

 Manual

Linear

 P/N: 208968 C

Mater

ial: 20# White Mead B

ond with 60# White Coated Cov

e

r

Ink

: PMS

 548 (

B

lue/Gr

ay)

S

ize: 8 1/2"

 x 5 1/2"

Summary of Contents for DEFIANT SSD

Page 1: ...nual Help Line 1 800 528 4454 FRONT COVER 1 OF 40 EMERGENCY ensor tatus isplay Featuring Defiant SSD DF 16 Owner s Manual Linear P N 208968 C Material 20 White Mead Bond with 60 White Coated Cover Ink PMS 548 Blue Gray Size 8 1 2 x 5 1 2 ...

Page 2: ...ection Association NFPA Rule 74 and UL 217 requirements Many insurance companies require you to meet these requirements to qualify for a discount Use only the SSD compatible smoke detector as described in Section 3 Defiant SSD Accessories of this manual NOTE Some cities and municipalities may require an alarm system permit Check with your local authorities before installing this system The DEFIANT...

Page 3: ...S 21 15 HOME AUTOMATION OUTPUT 22 HOME AUTOMATION INTERFACE 22 PROGRAMMABLE OPTIONS 22 16 EXPANDING YOUR SYSTEM 23 ADDING SENSORS TO THE SYSTEM 23 REMOVING SENSORS FROM THE SYSTEM 24 MAKING A SENSOR A 24 HOUR DOOR CHIME 24 MAKING A SENSOR INTERIOR 25 17 ADVANCED PROGRAMMING 26 LEARN MODE 26 ENTRY DELAY TIME 26 EXIT DELAY TIME 26 HOME AUTOMATION OUTPUT TIME 27 REMOTE CONTROL ARMING LEVEL 27 REMOTE ...

Page 4: ... An SSD Smoke Detector is required to create a UL Listed smoke alarm system See Section 16 Expanding Your System for details of how to program the SSD Smoke Detector into the Console 4 OF 40 EMERGENCY 1 DEFIANT SSD CONSOLE WIRELESS KEYPAD DOOR WINDOW SENSORS VIDEO TAPE YARD SIGN EMERGENCY OFF HOME AWAY Defiant SSD DF 16 Owner s Manual Linear P N 208968 C Material 20 White Mead Bond with 60 White C...

Page 5: ...on your custom call list The Console has panic button capabilities that are always ready to operate even when the Console is disarmed They can be triggered by a button on the Console the Wireless Keypad and portable remote controls Pressing the EMERGENCY button for two seconds will cause an immediate siren and call the central station if the optional dialer is installed IMPORTANT For personal emer...

Page 6: ...trance is gained Indicate locations for door window sensors interior motion detectors and external siren speakers Decide on a centralized location for the security Console 6 OF 40 CON S GARAGE S S MS S MD ES WK S S S MD MS S S MS CON DEFIANT SSD CONSOLE S DOOR WINDOW SENSOR WK WIRELESS KEYPAD MD MOTION DETECTOR ES EXTERNAL SIREN SD SMOKE DETECTOR GB GLASS BREAK SENSOR MS EXTERNAL MAGNETIC SWITCH L...

Page 7: ...e Detector Motion Detector UL NOTE Not tested by UL One button Key chain Remote Control Two button Key chain Remote Control UL NOTE Not tested by UL Glass break detector External Magnetic Switch 7 OF 40 Defiant SSD DF 16 Owner s Manual Linear P N 208968 C Material 20 White Mead Bond with 60 White Coated Cover Ink PMS 548 Blue Gray Size 8 1 2 x 5 1 2 5 ...

Page 8: ...onsole into the Learn Mode Learn Mode is used to add additional sensors to the system up to 16 total Your secret code can be changed using Learn Mode Various advanced system programming options can be made in Learn Mode 6 TERMINAL BLOCK Terminals for connection to an optional external siren speaker Home Automation Output to connect to a Home Automation controller 7 FUSE HOLDER Holds fuse for the b...

Page 9: ...e disarms the system Switching to Chime Mode stops the alarm siren Multiple beeps sound and status lights flash if an alarm has occurred Multiple beeps mean caution AN INTRUDER MAY STILL BE IN YOUR HOME Chime Mode is for monitoring doors and windows Use this mode as an automatic door chime when at home Opening any protected door or window causes Console to ding dong HOME Home Mode arms the perimet...

Page 10: ...c switch accessories WIRELESS KEYPAD For controlling the system without having to go to the Console Emergency alarm can be triggered from wireless keypad at any time UL NOTE For personal emergency use only Not for use as a UL Listed Medical Alert System Green operation light Internal 9 volt battery is monitored by the Console Keypad will sound a beep when its battery is low Pressing clears the key...

Page 11: ...ocate the Console within 8 feet of a telephone outlet for the optional Emergency Dialer A cover locking screw is provided to lock down the hinged top cover If desired the Console can be mounted on the wall with screws A wall mount template is provided on the back of the Quick Operation Guide NOTE If monitoring by the central station is desired do not wall mount until the Emergency Dialer is instal...

Page 12: ...et code by entering it then pressing TEST Don t forget your secret code write it down NOTE If you forget your code see the Advanced Programming section of this manual The Console will treat your secret code as a master secret code To create a restricted secret code see the Advanced Programming section of this manual NOTE The master secret code can be used to enter Learn Mode The restricted secret ...

Page 13: ...ews provided NOTE The keypad should be mounted at least three feet above ground level Hook the bottom edge of the keypad case together and snap the keypad onto the rear case WARNING The wireless keypad is designed for indoor use only 13 OF 40 USE THE FOUR SCRATCH DETERRENT PADS PROVIDED FOR TABLE TOP USE FROM TOP OF CASE TWIST SCREWDRIVER BETWEEN CASE HALVES UNTIL IT POPS OPEN ATTACH REAR CASE TO ...

Page 14: ...STICK TAPE Apply double stick tape supplied to back of sensors and magnets Screws are also provided to mount sensors and magnets Screws are preferred over the double stick tape in permanent installations NOTE Double stick tape is not allowed in UL installations 14 OF 40 SLIDE SWITCH TO THE INSTANT OR DELAYED POSITION MAGNET ON WINDOW SENSOR ON FRAME SENSOR ON FRAME MAGNET ON DOOR APPLY DOUBLE STIC...

Page 15: ...The two door window sensors supplied with the Console are pre programmed into the Console s memory as sensors 1 and 2 15 OF 40 MOUNT SENSOR PLATE TO FRAME ALIGN MAGNET PLATE NEXT TO SENSOR PLATE AND ATTACH TO DOOR 1 2 MAXIMUM SPACE BETWEEN SENSOR AND MAGNET PLATES SNAP SENSOR ONTO MOUNTING PLATE 1 2 MINIMUM MOUNT SENSOR PLATE TO FRAME ALIGN MAGNET PLATE NEXT TO SENSOR PLATE AND ATTACH TO WINDOW SP...

Page 16: ... and stick it in the area to the right of the sensor light Close the protected opening that you just labeled Repeat for each protected opening Press the AUTO key on the wireless keypad The sensor 16 status light should go on for a few seconds Stick the KEYPAD label in the spot for sensor 16 16 OF 40 EMERGENCY USE LABELS PROVIDED TO IDENTIFY SENSORS Defiant SSD DF 16 Owner s Manual Linear P N 20896...

Page 17: ...ressing OFF When the system is disarmed to Off Mode the Console will sound one Gong If an alarm has occurred multiple beeps will sound after disarming and the sensor light for the sensor s that caused the alarm will flash NOTE In Off Mode protected doors and windows cannot trigger the burglary alarm 17 OF 40 START HERE OFF YOUR SECRET CODE DONE 1 GONG OPTIONAL Defiant SSD DF 16 Owner s Manual Line...

Page 18: ...ng down the HOME key for two seconds Quick arming can be disabled see the Advanced Programming Section of this manual When the system is armed to the Home Mode the Console will sound a Gong and two Beeps Enter your secret code and press OFF or CHIME to disarm from Home Mode and or stop the alarm siren If an alarm has occurred multiple beeps will sound after disarming and the sensor light for the s...

Page 19: ...oor or window sensors The system will automatically bypass open doors and windows after sounding four high low beeps to warn you that a protected door or window is open Lit sensor status indicators show which sensors are open Bypassed sensors cannot cause an alarm until they are restored closed If you close the door or window after arming the system the sensor will be restored and can cause an ala...

Page 20: ...ding down the AWAY key for two seconds Quick arming can be disabled see the Advanced Programming Section of this manual EXIT DELAY For Leaving the Premises When the system is armed to the Away Mode the Console will sound a Gong and three Beeps During the 30 second Exit Delay the Console will sound beeps and the AWAY light will blink The Exit Delay gives you 30 seconds to leave the premises through...

Page 21: ...en entering AN INTRUDER MAY STILL BE IN YOUR HOME NOTE The Entry Delay time can be changed see the Advanced Programming Section of this manual AUTOMATIC BYPASSING OF SENSORS The Console can be armed with open door or window sensors The system will automatically bypass open doors and windows after sounding four high low beeps to warn you that a protected door or window is open Lit sensor status ind...

Page 22: ...y holding down the CHIME key for two seconds When the system is switched to the Chime Mode the Console will sound a Gong and one Beep Going to Chime Mode disarms the system and stops any alarms in progress NOTE In Chime Mode protected doors and windows cannot trigger the burglary alarm 22 OF 40 START HERE CHIME YOUR SECRET CODE DONE 1 GONG 1 BEEP OPTIONAL START IN OFF CHIME DONE 1 GONG 1 BEEP HOLD...

Page 23: ... bing sound as each sensor is tested Continue testing until there are no flashing status lights NOTE If the Console is left unattended in Test Mode it will automatically switch back to Off Mode after 3 minutes SENSOR LOW BATTERIES When a sensor s status light on the Console blinks the sensor has a low battery NOTE Don t confuse a blinking status light with a flashing status light flashing light is...

Page 24: ...ee the Advanced Programming Section of this manual for details 24 OF 40 X 10 BURGLAR ALARM INTERFACE CAN CONTROL HOUSE LIGHTS THROUGH X 10 SYSTEM X 10 DF 18 RELAY MODULE YOUR LOAD POWER SOURCE LIGHT EMITTING DIODE L E D LEARN HOME AUTOMATION OUTPUT TERMINALS INSIDE CONSOLE MINUS TERMINAL WILL SWITCH TO GROUND WHEN HOME AUTOMATION OUTPUT IS ACTIVATED POSITIVE TERMINAL PROVIDES 12 VOLTS DC AND IS CU...

Page 25: ...nused sensor number from 01 16 you must enter two digits example 5 05 The sensor indicator light will flash for the sensor number selected Activate the sensor To add wireless keypads press the keypad s AUTO key A single bing tone will sound when the sensor is learned by the Console A double buzz tone will sound if there is already another sensor programmed to that sensor number Exit Learn Mode by ...

Page 26: ...chime any time they re activated Chime only sensors will not be able to trigger the alarm in any Console mode The sensor must have already been learned by the Console see Adding sensors to the System for details Start with the Console in Off Mode Enter your secret code and press the LEARN button A gong and five beeps will sound The sensor status indicators will light for each sensor programmed int...

Page 27: ... gong and five beeps will sound The sensor status indicators will light for each sensor programmed into the Console Enter the sensor number from 01 16 you must enter two digits example 5 05 The sensor indicator light will flash for the sensor number selected Press HOME 7 then AWAY A bing tone will sound Exit Learn Mode by holding the OFF button for three seconds 27 OF 40 START IN OFF YOUR SECRET C...

Page 28: ... factory set Entry Delay time is 45 seconds The Entry Delay time can be adjusted from one to 255 seconds NOTE Don t make your Entry Delay too short You may not have enough time to disarm the system before an alarm The Console must be in Learn Mode to make this change Exit Learn Mode when all programming changes are complete EXIT DELAY TIME The factory set Exit Delay time is 30 seconds The Exit Del...

Page 29: ...xit Learn Mode when all programming changes are complete REMOTE CONTROL DISARMING LEVEL The factory setting causes the portable remote controls and wireless keypads to disarm to the Off Mode Alternately the remote controls and wireless keypads can disarm to the Chime Mode Changing this setting will affect all the portable remote controls and wireless keypads used with the system The Console must b...

Page 30: ... to cause an alarm the next time it is opened Alternately the Console can be programmed to not automatically restore sensors that close Bypassed sensors will remain bypassed until the system is disarmed The Console must be in Learn Mode to make this change Exit Learn Mode when all programming changes are complete DISABLING QUICK ARMING The factory setting allows the Console to be armed by holding ...

Page 31: ...e complete HOME AUTOMATION OUTPUT POLARITY The factory setting causes the Console s Home Automation Output to provide a current limited voltage source when activated Alternately the Console can be programmed so the Home Automation Output provides a current limited voltage source when deactivated The Console must be in Learn Mode to make this change Exit Learn Mode when all programming changes are ...

Page 32: ... must be in Learn Mode to make this change Exit Learn Mode when all programming changes are complete HOME AUTOMATION OUTPUT FLASHES DURING ALARM The factory setting causes the Console s Home Automation Output to activate when pressing the AUTO key or when it s triggered with a two button remote control In addition the Console can be programmed to flash the Home Automation Output during alarms The ...

Page 33: ...he Home Automation Output to be active when the system is armed so a light can be triggered displaying the arming status of the Console The Console must be in Learn Mode to make this change Exit Learn Mode when all programming changes are complete HOME AUTOMATION ACTIVATION TONE The factory setting causes the Console to sound a bing when the Home Automation Output is activated by pressing the AUTO...

Page 34: ... change the master secret code Exit Learn Mode when all programming changes are complete CONSOLE MASTER RESET Master resetting the Console will set all of the programming options back to the factory values NOTE Master resetting the Console will erase the master and restricted secret codes and remove all programmed sensors Disconnect the backup battery if installed Un plug the Console s wall transf...

Page 35: ...ING MODE 0 OFF MODE 1 CHIME MODE 0 60 AUTO BYPASS 0 OFF 1 ON 1 61 AUTO RESTORE 0 OFF 1 ON 1 62 QUICK ARMING 0 OFF 1 ON 1 65 EXIT DELAY BEEPS 0 OFF 1 ON 1 67 TEST SENSORS LIGHT 0 DISABLE 1 ENABLE 1 68 HOME AUTOMATION POLARITY 0 WHEN OFF 1 WHEN ON 1 69 HOME AUTOMATION DURING EXIT ENTRY 0 STANDARD 1 ON DURING EXIT ENTRY 0 70 HOME AUTOMATION WHILE ARMED 0 STANDARD 1 ON WHILE ARMED 0 71 HOME AUTOMATION...

Page 36: ...glass break sensor ONE BUTTON REMOTE CONTROL Arms and disarms system Comes with a snap action key chain TWO BUTTON REMOTE CONTROL Left button arms and disarms system Right button activates the Console s Home Automation Output Pressing both buttons triggers the Console s emergency alarm Not to be used as a UL Listed Medical Alert System Comes with a snap action key chain UL NOTE Product not tested ...

Page 37: ...uires door window sensor Can be used with magnetic switch contacts to double protect sliding glass doors EXTERNAL MAGNETIC SWITCH External switch for door window sensor Functions as a remote switch for existing sensor Up to 5 magnetic switch contacts can be used with one sensor For dual protection on partially opened windows RELAY MODULE Connects to the Home Automation Output Provides circuit isol...

Page 38: ... portable wireless signaling However there are some limitations which must be observed For U S installations only The radios are required to comply with FCC Rules and Regulations as Part 15 devices As such they have limited transmitter power and therefore limited range A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that occur on or near ...

Page 39: ...Copyright 1997 Linear Corporation Back Cover 40 OF 40 Defiant SSD DF 16 Owner s Manual Linear P N 208968 C Material 20 White Mead Bond with 60 White Coated Cover Ink PMS 548 Blue Gray Size 8 1 2 x 5 1 2 ...

Reviews: