background image

7  Automatic Door Force Setup

The opener automatically measures the door force throughout the entire travel of the door each time the opener 
cycles. The opener will automatically adjust to changing door hardware conditions over time due to weather and 
wear. Your installer has used these steps during setup of the opener. You can also perform these steps at any time.

Automatic Door Force Setup

1  Be  sure  that  the  trolley  latch  is  up  and  the  door  is 

connected to the opener.

2  Operate  the  door  through  four  complete  open  and 

close cycles.

8  Safety Reversal System Test

The opener determines that there is an obstruction if a higher than expected amount of force is detected during a 
door cycle. If an obstruction is encountered during a closing cycle, the opener and door will stop then fully open. If 
an obstruction is encountered during an opening cycle, the opener and door will stop.

Safety Reversal System Test

1  Lay a 2 x 4 board flat on the floor where it will be struck 

by the 

center of the door as it closes.

2  Verify that the door reverses when it strikes the board. 

The  door 

must  reverse  within  two  seconds  after 

striking the board.

9  Adjusting the Force Factor (Installation Option, Normally Not Used)

The opener uses the peak force measured during each of the last four complete cycles plus a “force factor” to 
calculate the maximum allowed force setting for the current door cycle. If the calculated maximum force setting is 
exceeded during the current door cycle, the opener reacts to the obstruction. As door hardware conditions change 
over time with weather and wear, the calculation of the maximum door force setting using the four cycle running 
average will compensate for the current conditions of the installation.

10 Field Reset

In installations where the door spring, door, or hardware is being replaced, and the opener was already programmed 
for the old door, reset the opener using the following steps.

11 Troubleshooting

LAMP FLASHES 

TROUBLE CODE

PROBLEM

CAUSE

REMEDY

1 FLASH

No problem

Remote control entered into 

memory

Add any additional remote controls 

(MegaCode™ type only)

2 FLASHES

Door won’t close

Shorted wall station wires

Check wall station wires. Be sure both are 

connected to the terminal screws. Check for 

a staple in the wall station wires. Remove any 

staples compressing the wire.

3 FLASHES

Door won’t close

Safety beam obstacle

Check for obstacles. Align the safety beam 

(Section 4)

4 FLASHES

Door reverses 

or won’t open or 

close

Open or Close force 

exceeded

Check for obstruction or binding of garage 

door. Perform field reset (Section 8) if 

necessary.

5 FLASHES

Door won’t open 

from remote 

control

Remote was activated while 

vacation switch was locked

Unlock vacation switch on wall station

6 FLASHES

Motor ran longer 

than 30 seconds

Mechanical or electronic 

failure

Call your local garage door professional

7 FLASHES

Limit error

Encoder has detected error 

or down limit set above up 

limit.

Re-set the open and close limits. If error 

occurs again, call your local garage door 

professional.

FCC NOTICE

Changes or modifications not expressly described in this manual or approved by the manufacturer could void the user’s authority to operate the equipment. This device 
complies with Industry Canada and FCC Part 15. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and (2) this device 
must accept any interference received, including interference that may cause undesired operation.

LIMITED WARRANTY

This Linear product is warranted to the original consumer against defects in material and workmanship for:

 

MODEL 

ELECTRONICS 

MECHANICAL 

MOTOR 

BELT 

CHAIN

 

LDCO800 

1 year 

5 years 

Lifetime 

Lifetime 

5 years

This product is warranted to the original consumer against defects in material and workmanship for the periods mentioned above. Linear will repair, or at its option, replace, 
any device that it finds requires service under this warranty, and will return the repaired or replaced device to the consumer at Linear’s cost. Devices must be sent to Linear 
for service at owner’s expense. This warranty does not apply to damage to the product from negligence, abuse, abnormal usage, misuse, accidents, normal wear or tear or 
due to failure to follow Seller’s instructions, or arising from improper installation, storage or maintenance. In no event will Linear be responsible for incidental, compensatory, 
punitive, consequential, indirect, special or other damages. The remedies provided by this warranty are exclusive. Some states do not allow the exclusion or limitation of 
incidental and consequential damages, so the above limitation or exclusion may not apply to you. Any warranties implied by law are limited to the time periods set forth 
above. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, 
and you may also have other rights which vary from state to state.
For warranty service and shipping instructions contact Linear at the phone number shown below. In order to be protected by this warranty, save your proof of purchase and 
send a copy with equipment should repair be required. All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear 
Technical Services at 1-800-421-1587 for an RPA# and other important details.

4  Testing the Infrared Safety Beam

The safety beam has two components, a sender and a receiver. The sender produces a narrow infrared beam that 
travels across the bottom of the door opening to the infrared receiver. If an object blocks the infrared beam while the 
door is closing, the door will stop, then reverse and fully open (the opener’s light will flash three times).
As a safety feature, the opener will ignore signals from all remote controls if the door is open and the 
infrared safety beam is blocked or out of alignment. In this case, the door can be forced closed by pressing 
and holding the wall station’s up/down arrow pushbutton (be sure the door area is in clear view).

Safety Beam Test

1  Check that the opener has power. The green lights on 

the sender and receiver should be lit.

2  If the receiver’s green light is on, but the red light is off, 

the receiver has power but is not detecting the infrared 

beam from the sender. The red light might flash when 

the beam is partially detected. This can be caused by 

mis-alignment or something blocking the beam. Adjust 

the  safety  beam  sender  and  receiver  while  watching 

the  receiver’s  red  light  (stay  out  of  the  beam  while 

aligning  it).  When  the  red  light  stays  on,  rotate  the 

sender towards the ceiling and stop when the red light 

on the receiver begins to flicker. Rotate the sender back 

towards a horizontal position with the floor and stop as 

soon as the red light on the receiver lights solid. The 

beam is now properly aligned.

SAFETY BEAM INDICATOR TABLE

GREEN ON

POWER ON

GREEN OFF

POWER OFF

RED ON

BEAM OK - NO BLOCKAGE

RED OFF

BEAM BLOCKED OR MIS-ALIGNED

RED FLASHING

BEAM ALIGNED POORLY

� 

NOTE:

 If the receiver’s red light remains off, check 

for: 1) Dirt on the receiver’s lens, 2) Sunlight shining 
into the receiver’s lens, 3) A short in the safety beam 
wiring (from staples or at the opener terminals).

3

 

With the door closed and the opener disengaged 

from  the  door,  press  the  wall  station’s  UP/DOWN 

ARROW button to move the traveler (the part on the 

belt or chain that the trolley engages with) to the up 

position (away from the door).

4  Push the wall station’s UP/DOWN ARROW button again. 

While the traveler is moving to the down position (toward 

the  door),  block  the  safety  beam.

  THE  TRAVELER 

MUST STOP, THEN REVERSE TO THE UP POSITION. 

The opener’s light and red light should flash three times.

5  Place an object in the path of the safety beam. Check 

that constant pressure is required on the wall station’s 

UP/DOWN  ARROW  button  to  cause  the  traveler 

to  move  toward  the  down  position.  Release  the 

pushbutton  before  the  opener  stops;  check  that  the 

traveler returns to the up position.

� 

NOTE:

 The garage door opener will not respond to a 

CLOSE command from a remote control if the safety 
beam is blocked.

6  To  reconnect  the  opener,  flip  the  release  lever  up. 

Raise the door manually until the opener reconnects.

5  Adjusting the Open and Close Limits

The limit settings control how far the door will open or close. The limits should be set so the door opens just short 
of any door stops, and closes at the floor level.
If required, use the following steps to adjust the limits. After beginning to adjust the limits, if no buttons are pressed 
for one minute, the opener will return to normal operation.

Adjusting the Open Limit

1  Use the wall station or a remote control to move the 

door to the open limit position.

2  On  the  back  of  the  opener,  press  both  the  UP  and 

LEARN buttons for three seconds. The green indicator 

and opener’s light will flash twice then stay on.

3  Use the UP and DOWN buttons to jog the door at slow 

speed to fine-tune the open limit position.

4  When  the  door  is  at  the  proper  open  limit  position, 

press the LEARN button to store the setting and exit 

setup. The green indicator and the opener’s light will 

flash two times. 

Adjusting the Close Limit

1  Use the wall station or a remote control to move the 

door to the close limit position.

2  On the back of the opener, press both the DOWN and 

LEARN  buttons  for  three  seconds. The  red  indicator 

and opener’s light will flash twice then stay on

3  Use the UP and DOWN buttons to jog the door at slow 

speed to fine-tune the close limit position.

4  When  the  door  is  at  the  proper  close  limit  position, 

press the LEARN button to store the setting and exit 

setup. The red indicator and the opener’s light will flash 

two times.

6  Replacing the Opener’s Lamp

If the opener’s safety lamp fails to light manually or when the opener is cycled, the light bulb needs replacing. Use 
the following steps to replace the light bulb.

1  Remove the light cover to expose the light bulb and 

lamp socket.

2  Replace the light bulb with a 100 watt maximum rough 

service bulb (sometimes called a garage door bulb).

3  Reattach the light cover.
4  Press the wall station’s lamp button to test the lamp.

  CAUTION 

Set the open and close limits carefully. Setting 

the limits beyond the distance that the door can 

travel could cause damage to the door, the door 

hardware, or opener.

Copyright © 2010 Linear LLC 

228356 C

PRINTER’S INSTRUCTIONS:

INSTR,HOMEOWNERS,LDCO; LINEAR P/N: 228356 C; INK: BLACK; MATERIAL: 20# MEAD BOND; SIZE: 11.000” x 17.000”; FOLDING: 1-FOLD VERTICAL, 1-FOLD HORIZONTAL, FINISH 8.500” X 5.500” WITH LOGO SHOWING; SCALE: 1-1; SIDE 2 OF 2 

SAFETY BEAM INDICATORS

RED LIGHT

GREEN LIGHT

GREEN LIGHT
ON = POWER ON
OFF = POWER OFF

RED LIGHT
ON = BEAM ALIGNED, NO OBSTRUCTION
OFF = BEAM NOT ALIGNED, OR OBSTRUCTION
BLINKING = BEAM NEEDS BETTER ALIGNMENT

ADJUSTING THE BEAM

1. ADJUST THE SENDER
AND RECEIVER UNTIL

THE RED INDICATOR
LIGHTS SOLID

2. ADJUST SENDER

UP UNTIL RECEIVER'S
RED INDICATOR FLASHES

3. ADJUST SENDER DOWN
JUST UNTIL RECEIVER'S

RED INDICATOR LIGHTS SOLID

BLOCK THE BEAM
WHILE THE TRAVELER
IS MOVING DOWN

TOWARD
DOOR

TOWARD
OPENER

UP

DOWN

CHECKING FOR REVERSAL

TRAVELER

THE TRAVELER MUST REVERSE
WHEN THE BEAM IS INTERRUPTED

PLACE AN OBJECT
IN THE BEAM'S PATH

VERIFY THAT CONSTANT
PRESSURE IS REQUIRED

ON THE WALL STATION'S
PUSHBUTTON TO MAKE
THE TRAVELER GO DOWN 

RELEASE PUSHBUTTON
BEFORE THE OPENER STOPS,

THE TRAVELER SHOULD
RETURN TO THE UP POSITION

CHECKING FORCED CLOSURE FEATURE

  WARNING 

With  the  door  closed,  disengage  the  trolley 

from the chain during these alignment tests by 

pulling the red release handle.

  WARNING 

Serious injury or death from a closing garage 

door may result because of failure to test and 

adjust safety reverse system. Repeat this test 

monthly and adjust as needed.

DOWN

UP

EXAMINE THE SPOT WHERE

DOOR CLOSES

ADJUSTING THE CLOSE LIMIT

DOWN

UP

EXAMINE THE SPOT WHERE
THE DOOR OPENS

ADJUSTING THE OPEN LIMIT

  WARNING 

Always perform the Safety Reversal System Test 

after  making  any  adjustments  to  the  opener. 

PERFORM THE SAFETY REVERSAL SYSTEM TEST 

MONTHLY!

  WARNING 

STAY  CLEAR  OF  THE  DOOR  DURING  THIS 

PROCEDURE!

TEST WITH SMALL OBSTACLE

THE DOOR MUST REVERSE

WITHIN 2-SECONDS AFTER

IMPACT WITH A 2 x 4 BOARD

2 x 4 BOARD LAID FLAT

UNDER CENTER OF DOOR

TESTING THE SAFETY REVERSAL SYSTEM

OPERATE THE DOOR THROUGH
FOUR  FULL OPEN AND CLOSE CYCLES

DOOR FORCE SETUP

4

4

  CAUTION 

Do  not  cycle  the  opener  full  travel  without 

the door connected. The automatic door force 

setting  will  adjust  to  the  unloaded  condition 

and may trip the safety system when the door 

is reconnected.

Changing the Force Factor Setting

As  an  installation  option,  the  opener’s  “force  factor” 
can  be  adjusted  to  change  the  amount  of  pressure 
exerted on an obstacle before the opener reacts to the 
obstruction.

1  Press  both  the  UP  and  DOWN  buttons  for  three 

seconds. The red and green indicators and opener’s 

light will flash twice.

2  Use the UP or DOWN buttons to set the force factor. 

Pressing the UP button 

increases

 the force factor, 

pressing  the  DOWN  button 

decreases

  the  force 

factor.

FORCE FACTOR INDICATOR TABLE

GREEN ON

LOW FORCE FACTOR

RED & GREEN ON MEDIUM FORCE FACTOR

RED ON

HIGH FORCE FACTOR

3  After  selecting  the  force  factor,  press  the  LEARN 

button  to  store  the  setting  and  exit  setup. The  red 

and green indicators and the opener’s light will flash 

two  times.  (If  the  force  factor  is  not  set  within  one 

minute, the opener will return to normal operation at 

its previous force factor setting.)

4  After changing the force factor setting, perform the 

Safety System Reversal Test.

1  Press and hold down the UP, DOWN, and LEARN 

buttons at the same time for ten seconds. The red 

and green indicators and the opener’s light will flash 

twice.

2  Release  the  buttons.  The  opener  will  reset  force 

setting and erase all set limits, 

but will still retain 

all programmed remote controls in memory.

3  AFTER  PERFORMING  A  FIELD  RESET,  BOTH 

THE  OPEN  AND  CLOSE  LIMITS  MUST  BE 

ADJUSTED AND THE AUTOMATIC DOOR FORCE 

SETUP  COMPLETED  BEFORE  THE  OPENER 

WILL FUNCTION.