-19-
<LIN setting>
● Baud Rate
Select from “2400bps”, “9600bps” or “19200bps”. Also, it is possible to set an arbitrary speed.
(Any four digits between 400bps to 26000bps.)
● ID Filter
Set “0”, “1” or “*(don’t care)” in the ID5-ID0 (5bit – 0bit).
(Example)
ID Filter : - - - 0 0 0 0 0 0 => Display frames of ID “00”
ID Filter : - - - 0 0 0 0 0 1 => Display frames of ID “01”
ID Filter : - - - 0 0 0 0 0 * => Display frames of ID “00” or “01”
・
Cut
NOT capture the frames which have corresponding ID by a software filter.
Select standard format of extended format at the cut configuration tab and set the ID by HEX
(“0” - “F”, “*”, (Don’t care)). (You can set up to 8 items)
Configure values within the scope of ID:0 – 7FFh when it is standard format,
and configure values within the scope of ID:0 – 1FFFFFFFh when it is extended format.
Note: If there is no entry for the blanks when the cut filter is valid, all the ID frame will be captured.
(Example) Cuts the IDs of 020h – 02Fh from the monitoring target when it is standard format and the
ID is configured for 02*h (HEX).
・
Pass & Cut
The pass filter and the cut filter will be valid.
・
Acceptance & Pass & Cut
The acceptance filter, the pass filter, and the cut filter will be valid.