-30-
■ Registration of the Transmission Data
◆
Master Simulation
Select each table (0 to F) in “Simulation data table
”
.
When sending data to the slave node, in the settings for each table set the frame type to “Response
”
, set
the slave ID to “ID
”
, and set the data to be sent to “Data
”
. When receiving data from a slave node, set
the frame type to “Header
”
and the slave ID to “ID
”
.
When it is the master, register the simulation data table numbers 0 to F set here to the schedule table
numbers No. 0 to F.
◆
Slave Simulation
Select each table (0 to F) in the “Simulation data table
”
.
In the settings in each table, set the frame type to “Response
”
, set the ID which responds to “ID
”
, and
set the data to be sent to “Data
”
.
When it is the master, register the simulation data table numbers 0 to F set here to the schedule table
numbers No. 0 to F.
■ Start the Simulation
◆
Master Simulation (When the schedule is OFF)
1. Execute “Run measurement
”
.
2. Click the button of the table number to be transmitted.
* The operation panel is displayed in the order of simulation data table numbers, not in the order of
scheduled tables.
* The operation panel does not open when measurement is stopped or in the online mode or analog
mode.
* “Wake Up (80h)
”
can transmit 80h as a Wake-up signal, and “Wake Up
”
can transmit a dominant of
0.25μsec or more.
* Dominant time is the time when 1 bit time of the set communication speed is 0.25 μsec or more in
total.
* “Stop repeated sending
”
cannot be used.
◆
Master Simulation (When the schedule is ON)
1. Execute “Run measurement
”
.
2. Data will be sent automatically in the order set in the schedule table.
* In the protocol analyzer mode, only “WakeUp (80h)
”
and "WakeUp
”
can be sent from the operation
panel, but each table number button and “Stop repeated sending
”
cannot be used.
* Master simulation (when the schedule is ON) is also available in communication logger mode.
◆
Slave Simulation
1. Execute “Run measurement
”
.
2. If there is a send request from the master and it matches the ID set in tables 0 to F, the data in that
table will be sent automatically.
* Data will not be transmitted unless there is a transmission request from the master.
* In protocol analyzer mode, only “WakeUp (80h)
”
and “WakeUp
”
can be sent from the operation panel,
but each table number button and “Stop repeated sending
”
cannot be used.
* The slave simulation is also available in the communication logger mode.
■ Stop the Simulation
1. Close the “operation panel”.
2. Execute “Stop measurement
”.
(If you press the stop measurement without closing the operation panel, the operation panel will be closed
automatically.)
<
Caution
>
The operation panel cannot be used in the communication logger mode.
Transmission cannot be stopped unless the measurement is stopped.