-38-
Chapter 9 Specifications
9.1 Interface (CAN/LIN/External Input)
Dsub 25pin connector is for the port of CAN, LIN and external input signal.
Pin NO
Signal name
Function
1
BATT
LIN Battery Power and Power for the analyzer
4
GND
Signal Ground
7
GND
Signal Ground
9
EXIN1
External Input 1
10
EXIN2
External Input 2
11
EXIN3
External Input 3
12
EXIN4
External Input 4
14
TRG_IN
Trigger Input
15
CAN_1H
CAN Signal (channel 1)
16
CAN_1L
17
TRG_OT2
Trigger Output 2
18
TRG_OT1
Trigger Output 1
19
CAN2_H
CAN Signal (channel 2)
21
CAN2_L
22
GND
Signal Ground
23
LIN1
LIN Signal (channel 1)
24
LIN2
LIN Signal (channel 2)
* No. 4, 7 and 22 are connected internally.
Connect the ground of same electric potential to those pins.
9.2 External Input/Output Terminal
<External trigger input/output terminal>
Pin NO
Signal name
Function/Specification
14
TRG_IN
External trigger input TTL level input Range: -0.5V - 6.0V
17
TRG_OT2
External trigger output 2 Open drain output +5V, 10KΩ pull-up
18
TRG_OT1
External trigger output 1 Open drain output +5V, 10KΩ pull-up
Pin NO
Signal name
Function/Specification
9
EXIN1
Input 1, 160K pull-down, Range: ±25V
10
EXIN2
Input 2, 160K pull-down, Range: ±25V
11
EXIN3
Input 3, 160K pull-down, Range: ±25V
12
EXIN4
Input 4, 160K pull-down, Range: ±25V
* EXIN1-EXIN4 are non-isolated (use same ground).
* Range of analog measurement is ±15V. Max. Input is ±32V.
<External input signal>
1
13
14
25