-4-
Chapter 1 Before Using the Product
LE-270AR/LE-270GR is the CAN/LIN communication analyzer, which can be used as a PC-connectable
protocol analyzer and PC-less Data logger. It has two High-speed CAN transceivers, and two LIN transceiv-
ers. It monitors two channels of CAN or LIN, or one CAN and one LIN channels. In addition, four channels of
Analog/Digital signals can be recorded. LE-270GR has GPS receiver and acceleration sensor and can register
positioning and acceleration information besides CAN/LIN communication data. Power failure protection,
water-proofing and low power consumption widens the usage of analyzer such as in the automation factories
and other production factories,
1.1 Composition
W
hen you unpack the product, please make sure of the following
Protocol
Analyzer
:
1
Utility
CD
(CD-ROM)
:
1
SDHC
card
(8GB)
:
1
Mini
USB
cable :
1
CAN/LIN Dsub cable (Model: LE-25M3A-1) : 1
Power plug cable (Model: SIH-2PG) : 1
Instruction
Manual
:
1
(This
book)
Warranty :
1
* Please contact LINEEYE distributor or us if you find any insufficient part of any damage to the product
caused by transportation.
* Please keep the box carefully to use it when sending the product back to us for repair etc.
● Utility CD
Utility CD contains the analysis software, driver and some instruction manuals of analyzer and its options.
You can download the update file of software from https://www.lineeye.com
1.2 Outline
■ Functions
1). On-line Monitoring
Monitor the transmission/reception data on-line to check the existence of hindrance and communication
data in the line or to analyze the communication.
2). Simulation function
The product takes a role of a node of CAN/LIN and transmits the data frame or remote frame set by the
user.
3). Analog measurement function
The product measures and records the voltage of the range from –15V to +15V with the specified
interval(1ms to 10min).
■ Feature
* Measure two channels of CAN/LIN in combination and four channels of Analog/Digital signals at the
same time.
* High speed(TJA1050) of CAN transceivers are selectable from the software.
* Powerful trigger function and ID filter for sufficient analysis.
* Record measured data continuously in the HDD of PC or SD card.
(SD card: LE-270AR supports up to 16GB while LE-270GR supports up to 32GB).
* Specify the recording time by Real Time Clock. Turn On/Off the power automatically.
* Power failure protection and wide range of ambient temperature make it possible to use it in the severe
conditions. (-20
℃
- +60
℃
)
* Compact size. Able to use the 35mm DIN rail.
*You can receive the file of the measuring data in logger mode through Wi-Fi.
→ 6-3 Read the logger file via Wi-Fi
(The Wi-Fi function is available only in Japan, USA, Canada, and EU nations where the product is
needed to be compliant with RE directive (2014/53/EU). )
*You can log the GPS positioning and acceleration data. [Supported only by LE-270GR]
*The measurement port is isolated from the USB port by the galvanic isolation [Only LE-270GR]