background image

Linksys ATA Administration Guide

114

Regional page

Voice tab > Regional page >

Ring and Call Waiting Tone Spec section

IMPORTANT: 

Ring and Call Waiting tones don’t work the same way on all phones. When setting 

ring tones, consider the following recommendations:

1. Begin with the default Ring Waveform, Ring Frequency, and Ring Voltage. 

2. If your ring cadence doesn’t sound right, or your phone doesn’t ring, change your Ring 

Waveform, Ring Frequency, and Ring Voltage to the following:

a. Ring Waveform: Sinusoid

b. Ring Frequency: 25

c. Ring Voltage: 80V

Voice tab > Regional page >

Control Timer Values (sec) section

Ring6 Name 

Name in an INVITE’s Alert-Info Header to pick distinctive ring/CWT 6 for the 
inbound call.

The default is 

Bellcore-r6

Ring7 Name 

Name in an INVITE’s Alert-Info Header to pick distinctive ring/CWT 7 for the 
inbound call.

The default is 

Bellcore-r7

.

Ring8 Name 

Name in an INVITE’s Alert-Info Header to pick distinctive ring/CWT 8 for the 
inbound call.

The default is 

Bellcore-r8

Ring9 Name 

Name in an INVITE’s Alert-Info Header to pick distinctive ring/CWT 9 for the 
inbound call. This field is for the SPA2102 only.

The default is 

Bellcore-r9

Field

Description

Hook Flash Timer Min 

Minimum on-hook time before off-hook qualifies as hook-flash. Less than 
this the on-hook event is ignored. Range: 0.1–0.4 seconds.

The default is 

0.1

.

Hook Flash Timer Max 

Maximum on-hook time before off-hook qualifies as hook-flash. More than 
this the on-hook event is treated as on-hook (no hook-flash event). Range: 
0.4–1.6 seconds.

The default is 

0.9

.

Callee On Hook Delay 

Phone must be on-hook for at this time in sec before the ATA device will tear 
down the current inbound call. It does not apply to outbound calls. Range: 
0–255 seconds.

The default is 

0

.

Reorder Delay 

Delay after far end hangs up before reorder tone is played. 0 = plays 
immediately, inf = never plays. Range: 0–255 seconds.

The default is 

5

.

Summary of Contents for RTP300 - Broadband Router With 2 Phone Ports

Page 1: ...ADMINISTRATION GUIDE Linksys ATA Administration Guide Version 2 0 ...

Page 2: ...pter 2 Basic Administration and Configuration of Your Linksys ATA Device 28 Basic Services and Equipment Required 28 Downloading Firmware 29 Basic Installation and Configuration 30 Upgrading the Firmware for the Linksys ATA Device 30 Setting up Your Linksys ATA Device 31 Using the Administration Web Server 31 Connecting to the Administration Web Server 32 Setting Up the WAN Configuration for Your ...

Page 3: ... 64 Inbound Call Routing for a Trunk Group 64 Contact List for a Trunk Group 65 Outgoing Call Routing for a Trunk Group 66 Configuring a Trunk Group 67 Trunk Group Management 68 Setting the Hunt Policy 69 Additional Notes About Trunk Groups 69 Chapter 5 Configuring Music on Hold 70 Using the Internal Music Source for Music On Hold 70 Using the Internal Music Source 70 Changing the Music File for t...

Page 4: ...ction 91 LAN Networking Settings section 91 Static DHCP Lease Settings section 91 Application page 92 Port Forwarding Settings section 92 DMZ Settings section 92 Miscellaneous Settings section 93 System Reserved Ports Range section 93 Appendix B Linksys ATA Voice Field Reference 94 Info page 94 Product Information section 95 System Status section 95 Line Status section 95 System Information sectio...

Page 5: ...n section 130 Supplementary Service Subscription section 130 Audio Configuration section 132 Gateway Accounts section SPA3102 AG310 132 VoIP Fallback to PSTN section SPA3102 AG310 133 Dial Plan section 133 FXS Port Polarity Configuration section 135 Trunk Group page SPA8000 135 Line Enable section 135 Network Settings section 136 SIP Settings section 136 Subscriber Information section 138 Dial Pla...

Page 6: ...T 174 SPA2102 174 SPA3102 175 SPA8000 175 RTP300 176 WRP400 176 WRTP54G 177 AG310 177 Appendix F Warranty Information 178 Limited Warranty 178 Exclusions and Limitations 178 Obtaining Warranty Service 179 Technical Support 179 Appendix G Regulatory Information 180 Federal Communications Commission Interference Statement 180 Industry Canada Statement 180 Règlement d Industry Canada 180 EC Declarati...

Page 7: ...Table of Contents Linksys ATA Administration Guide vi Schedule 3 197 Appendix J Contacts 200 ...

Page 8: ...ge viii Document Purpose and Contents on page ix Related Documentation on page x Online Resources on page xi Copyright and Trademarks on page xi Finding Information in PDF Files on page xii Document Audience This document is written for the following audience Service providers offering services using LVS products VARs and resellers who need LVS configuration references System administrators or any...

Page 9: ...5 2 5 SPA3102 5 1 7 SPA8000 6 1 3 RTP300 3 1 24 WRP400 1 00 06 WAG54GP2 Model Version 1 1 01 02 Model Version 2 2 01 06 AG310 1 00 04 Typographic Element Meaning Boldface May indicate either of the following A user interface element that you need to click select or otherwise act on A literal value to be entered in a field Italic May indicate either of the following A variable that should be replac...

Page 10: ...ility This chapter provides configuration details for the purpose of helping you to ensure that your infrastructure properly supports voice services Chapter 4 Configuring Voice Services This chapter describes how to configure your ATA device to meet the customer s requirements for voice services Chapter 5 Configuring Music on Hold This chapter explains how to configure Music on Hold using either a...

Page 11: ...OTE These documents and more are available at Linksys com Appendix I Software License Agreement Appendix H Safety Information Appendix J Contacts Document Title Description Intended Audience Linksys Phone Administration Guide Configuration and management of IP phones Deployment options with or without the SPA9000 IP PBX SPA9x2 series IP phones VARs and Service Providers Linksys SPA9x2 Phone User G...

Page 12: ...Rs and Service Providers Linksys Provisioning Guide Provisioning LVS components Service Providers only Resource Link Linksys www linksys com Linksys International www linksys com international Glossary www linksys com glossary Network Security www linksys com security Linksys is a registered trademark or trademark of Cisco Systems Inc and or its affiliates in the U S and certain other countries Co...

Page 13: ...ick the arrow next to the Find text box to refine your search by choosing special options such as Whole words only 3 Press Enter Acrobat displays the first instance of the search term Press Enter again to continue to more instances of the term Finding Text in Multiple PDF Files The Search window lets you search for terms in multiple PDF files that are stored on your PC or local network The PDF fil...

Page 14: ...arch criteria click Use Advanced Search Options and choose the options you want e Click Search 4 When the Results appear click to open a folder and then click any link to open the file where the search terms appear NOTE For more information about the Find and Search functions see the Adobe Acrobat online help ...

Page 15: ...e ports using standard analog telephone equipment The Linksys ATA device connects to a wide area IP network such as the Internet through a broadband DSL or cable modem or router This chapter introduces the functionality of the Linksys ATA devices and describes the features that are available Refer to the following topics Comparison of ATA Devices section on page 16 Linksys ATA Connectivity Require...

Page 16: ...P service deployment are advised to test all functionality they plan to support before putting the Linksys ATA device in service By implementing Linksys ATA devices with the SIP protocol intelligent endpoints at the edges of a network perform the bulk of the call processing This allows the deployment of a large network with thousands of subscribers without complicated expensive servers Product Nam...

Page 17: ...TN gateways They provide PSTN connectivity in addition to a single FXS port In addition the AG310 and WAG54GP2 provide an ADSL2 gateway The WRP400 RTP300 and WRTP54G routers provide ports for analog telephone devices and provide QoS in the form of priority packet queueing SPA3102 Broadband router Broadband router SPA8000 PAP2T DSL cable modem WAG54GP2 AG310 WRP400 RTP300 WRTP54G and SPA2102 Ethern...

Page 18: ...t Address Translation PAT The packet is then routed back to the internal network on the Linksys ATA device by the local router or the ISP router Problems can occur with calls between phones connected to the Linksys ATA device when an outbound proxy or a router with hairpinning support is not available The Linksys ATA device cannot directly connect the two telephone devices but requires a local or ...

Page 19: ...ice attached to the LAN port is assigned the network address 192 168 0 0 with a subnet mask of 255 255 255 0 If there is a network address conflict with a device on the Ethernet port the network address of the device on the LAN port is automatically changed to 192 168 1 0 Notes The IVR functions are accessed by connecting an analog telephone to Line 1 For proper operation the service provider shou...

Page 20: ...on the Ethernet port the network address of the device on the LAN port is automatically changed to 192 168 1 0 Notes The IVR functions are accessed by connecting an analog telephone to Line 1 For proper operation the service provider should use an Outbound Proxy to forward all voice traffic when the SPA3102 is located behind a router If necessary explicit port ranges can be specified for SIP and R...

Page 21: ... to the SPA8000 router but they must be distributed as shown Notes With the SPA8000 use line 1 or line 2 to access the IVR functions See the SPA8000 Quick Installation Guide for IVR instructions For proper operation the service provider should use an Outbound Proxy to forward all voice traffic when the SPA8000 is located behind a router If necessary explicit port ranges can be specified for SIP an...

Page 22: ...ksys ATA Voice Field Reference on page 94 See also Supported Codecs on page 44 for a list of which codecs are supported on each Linksys ATA device NOTE When no static payload value is assigned per RFC 1890 the Linksys ATA device can support dynamic payloads for G 726 Codec Voice Compression Algorithm Description G 711 A law and mμ law This very low complexity codec supports uncompressed 64 kbps di...

Page 23: ...s ATA Software Features The following table summarizes other features provided by Linksys ATA devices Feature Description Streaming Audio Server See Configuring a Streaming Audio Server on page 71 T 38 Fax Relay See Using a FAX Machine SPA2102 SPA3102 or SPA8000 on page 45 Silence Suppression See Silence Suppression and Comfort Noise Generation on page 48 Modem and Fax Pass Through Modem pass thro...

Page 24: ...is can enhance the reliability of DTMF transmission required by many IVR applications such as dial up banking and airline information DTMF is configured in the DTMF Tx Mode parameter found in the Line tabs See the Linksys ATA Voice Field Reference on page 94 Call Progress Tone Generation The Linksys ATA device has configurable call progress tones Call progress tones are generated locally on the AT...

Page 25: ...device allows the polarity to be set when a call is connected and when a call is disconnected This feature is required to support some pay phone system and answering machines Polarity Control is configured in the Line and PSTN Line tabs See Linksys ATA Voice Field Reference on page 94 Calling Party Control Calling Party Control CPC signals to the called party equipment that the calling party has h...

Page 26: ... acts as the audio transmitter and receiver while the other device acts as the audio mirror The audio mirror transmits the audio packets that it receives back to the transmitter receiver instead of transmitting the data sampled on its local microphone IP phone or attached analog telephone ATA type device Media loopback is configured in the User tab See Linksys ATA Voice Field Reference on page 94 ...

Page 27: ...the communication between the SIP proxy and the device is either severed or degraded Whenever an expected SIP response is not received within a programmable amount of time after the corresponding SIP command is sent the DHCP Renewal on Timeout feature automatically causes the device to request a renewal of its IP address If the DHCP server returns the IP address that it originally assigned to the ...

Page 28: ...Administration Web Server section on page 31 Upgrading Rebooting and Resyncing Your Linksys ATA Device section on page 34 Provisioning Your Linksys ATA Device section on page 35 Basic Services and Equipment Required To configure your Linksys ATA devices you need the following services and equipment An integrated access device or modem for broadband access to the Internet Internet Telephony Service...

Page 29: ... Under Firmware click the link for the latest version of the firmware NOTE If you are using Windows XP Service Pack 2 SP2 and Internet Explorer you may see the Pop up blocked message in your browser information bar If you see this message click the information bar and select Temporarily Allow Pop ups Then click the link again 6 Click Save in the File Download dialog box that appears 7 In the Save ...

Page 30: ...omputer is connected to the Ethernet port of the Linksys ATA device the default IP address is 192 168 0 1 3 Use the administration computer to install the latest firmware a Extract the Zip file and then run the executable file to upgrade the firmware b When the Firmware Upgrade Warning window appears click Continue c In the next window that appears enter the IP address of the Linksys ATA device an...

Page 31: ...ess admin voice If the password has been set for the Administrator account the browser prompts for authentication The User account name and the Administrator account name cannot be changed When browsing pages with the Administrator account privilege you can switch to User account privilege by clicking the User Login link If the User account password is set the browser prompts for authentication wh...

Page 32: ...the top right corner of the page Then click Advanced NOTE By default no password is required You can assign an administrative password later but it is convenient not to use a password during the initial configuration Setting Up the WAN Configuration for Your Linksys ATA Device 1 Start Internet Explorer connect to the administration web server and choose Admin access with Advanced settings 2 Click ...

Page 33: ... To use VoIP phone service you must configure your Linksys ATA device to the Service Provider 1 Start Internet Explorer connect to the administration web server and choose Admin access with Advanced settings 2 Click Voice tab Line N where N is the line number that you want to configure 3 Enter the account information for your ITSP The following is the minimum required configuration to connect the ...

Page 34: ... these settings to resolve issues that arise when using a ATA on a network behind a Network Address Translation NAT device See the Network Address Translation NAT and Voice over IP VoIP on page 38 for further information Subscriber Information You can configure security parameters See the Secure Call Implementation on page 57 for further information Dial Plan You can configure a dial plan for a sp...

Page 35: ...y when it is idle If no parameter follows resync the Profile Rule setting from the Provisioning page is used If no protocol is specified TFTP is assumed If no server name is specified the host that requests the URL is used as server name If no port is specified the default port is used 69 for TFTP 80 for HTTP and 443 for HTTPS The profile path is the path to the new profile with which to resync fo...

Page 36: ... desired firmware image URL into the ATA device via a remote profile resync For further information about remote provisioning refer to the Linksys SPA Provisioning Guide Configuration Profile The ATA configuration profile can be either an XML file or a binary file with a proprietary format The XML file consists of a series of elements one per configuration parameter encapsulated within the element...

Page 37: ...s and other control characters Further to distinguish between Lines 1 2 3 and 4 corresponding parameter names are augmented by the strings _1_ _2_ _3_ and _4_ For example Line 1 Proxy is named Proxy_1_ in XML profiles Parameters in the case of source text files for the SPC tool are similarly named except that to differentiate Line 1 2 3 and 4 the appended strings 1 2 3 or 4 are used For example th...

Page 38: ... with NAT some form of NAT traversal is required Some ITSPs provide NAT traversal but some do not If your ITSP does not provide NAT traversal you have several options NAT Mapping with Session Border Controller on page 38 NAT Mapping with SIP ALG Router on page 38 Configuring NAT Mapping with a Static IP Address on page 39 Configuring NAT Mapping with STUN on page 40 NAT Mapping with Session Border...

Page 39: ...nd Port Fast on the ports to which the SPA devices are connected NOTE Use NAT mapping only if the ITSP network does not provide a Session Border Controller functionality 1 Connect to the administration web server and choose Admin access with Advanced settings 2 Click Voice tab SIP 3 Scroll down to the NAT Support Parameters section and then enter the following settings to support static mapping to...

Page 40: ...your router uses asymmetric NAT See Determining Whether the Router Uses Symmetric or Asymmetric NAT on page 41 You must have a computer running STUN server software The LAN switch must be configured to enable Spanning Tree Protocol and Port Fast on the ports to which the SPA devices are connected NOTE Use NAT mapping only if the ITSP network does not provide a Session Border Controller functionali...

Page 41: ... Determining Whether the Router Uses Symmetric or Asymmetric NAT STUN does not work on routers with symmetric NAT With symmetric NAT IP addresses are mapped from one internal IP address and port to one external routable destination IP address and port If another packet is sent from the same source IP address and port to a different destination then a different IP address and port number combinatio...

Page 42: ...complete the following task a Click Voice tab Line N where N represents the line interface number b In the SIP Settings section choose full from the SIP Debug Option field 6 Click Submit All Changes 7 View the syslog messages to determine whether your network uses symmetric NAT Look for a warning header in the REGISTER messages such as Warning 399 spa Full Cone NAT Detected Firewalls and SIP To en...

Page 43: ...r you can adjust the SIP timer values as needed to ensure interoperability with your ISTP For example if SIP requests are returned with an invalid certificate message you may need to enter a longer SIP T1 retry value To view the default settings or to make changes open the Voice SIP page and scroll down to the SIP Timer Values section For field descriptions see SIP Timer Values sec section on page...

Page 44: ...age 49 Secure Call Implementation on page 57 SIP Trunking and Hunt Groups on the SPA8000 on page 61 Supported Codecs The following list shows the current supported codecs for each Linksys ATA device If you need to change the G711u codec which is configured by default set your preferred codecs in the FXS Line tab s Audio Configuration You may set your first second and third preferred codec See Link...

Page 45: ... 5 6 and 7 8 for a maximum of four connections To optimize fax completion rates complete the following steps 1 Upgrade the Linksys ATA firmware to the latest version 2 Ensure that you have enough bandwidth for uplink and downlink For G 711 fallback it is recommend to have approximately 100Kbps For T 38 allocate at least 50 kbps 3 To optimize G 711 fallback fax completion rates set the following on...

Page 46: ...teway is correctly configured for T 38 with the SPA dial peer For example fax protocol T38 fax rate voice fax relay ecm disable fax nsf 000000 no vad Fax Troubleshooting If have problems sending or receiving faxes complete the following steps 1 Verify that your fax machine is set to a speed between 7200 and 14400 2 Send a test fax in a controlled environment between two Linksys ATAs 3 Determine th...

Page 47: ...nt after first ring same as ETSI FSK sent after first ring no polarity reversal or DTAS DTMF Finland Sweden CID only DTMF sent after polarity reversal and no DTAS and before first ring DTMF Denmark CID only DTMF sentbefore first ring with no polarity reversal and no DTAS ETSI DTMF CID only DTMF sent after DTAS and no polarity reversal and before first ring ETSI DTMF With PR CID only DTMF sent afte...

Page 48: ...present the silence suppression and comfort noise generation is activated This is accomplished by removing and not transmitting the natural silence that occurs in normal two way connection The IP bandwidth is used only when someone is speaking During the silent periods of a telephone call additional bandwidth is available for other voice calls or data traffic because the silence packets are not be...

Page 49: ...implemented Refer to the following topics Digit Sequences on page 49 Digit Sequence Examples on page 51 Acceptance and Transmission the Dialed Digits on page 52 Dial Plan Timer Off Hook Timer on page 53 Interdigit Long Timer Incomplete Entry Timer on page 54 Interdigit Short Timer Complete Entry Timer on page 55 Digit Sequences A dial plan contains a series of digit sequences separated by the char...

Page 50: ...esses 8 followed by a seven digit number the system automatically replaces the dialed 8 with 1650 If the user dials 85550112 the system transmits 16505550112 EXAMPLE 2 1 xxxxxxxxxx In this example no digits are replaced When the user enters a 10 digit string of numbers the number 1 is added at the beginning of the sequence If the user dials 9725550112 the system transmits 19725550112 comma Enter a...

Page 51: ...git local number EXAMPLE 1 8 xx 9 xxxxxxx 9 1 2 9 xxxxxxxxx 8 1212 xxxxxxx 9 1 2 9 xxxxxxxxx 9 1 900 xxxxxxx 9 011xxxxxx 0 49 11 9 1 2 9 xxxxxxxxx This example is useful where a local area code is required After a user presses 9 an external dial tone sounds The user must enter a 10 digit number that begins with a digit 2 through 9 The system automatically inserts the 1 prefix before transmitting t...

Page 52: ...e includes two digit sequences separated by the pipe character The first sequence allows a user to dial 0 for an operator The second sequence allows the user to enter 411 for local information or 911 for emergency services Acceptance and Transmission the Dialed Digits When a user dials a series of digits each sequence in the dial plan is tested as a possible match The matching sequences form a set...

Page 53: ...ow more time for users to start dialing after taking a phone off hook EXAMPLE P9 9 8 1408 2 9 xxxxxx 9 8 1 2 9 xxxxxxxxx 9 8 011xx 9 8 xx 1 8 xx P9 After taking a phone off hook a user has 9 seconds to begin dialing If no digits are pressed within 9 seconds the user hears a reorder fast busy tone By setting a longer timer you allow more time for users to enter the digits A timeout occurs The numbe...

Page 54: ...digit sequences in the dial plan Unless the user enters another digit within the specified number of seconds the entry is evaluated as incomplete and the call is rejected The default value is 10 seconds Note This section explains how to edit a timer as part of a dial plan Alternatively you can modify the Control Timer that controls the default interdigit timers for all calls See Resetting the Cont...

Page 55: ...e entire dial plan EXAMPLE S 6 9 8 1408 2 9 xxxxxx 9 8 1 2 9 xxxxxxxxx 9 8 011xx 9 8 xx 1 8 xx S 6 While entering a number with the phone off hook a user can pause for up to 15 seconds between digits before the Interdigit Short Timer expires This setting is especially helpful to users such as sales people who are reading the numbers from business cards and other printed materials while dialing Set...

Page 56: ...E If you need to edit a timer setting only for a particular digit sequence or type of call you can edit the dial plan See About Dial Plans on page 49 1 Connect to the administration web server and choose Admin access with Advanced settings 2 Click Voice tab Regional 3 Scroll down to the Control Timer Values section 4 Enter the desired values in the Interdigit Long Timer field and the Interdigit Sh...

Page 57: ... supports call waiting caller ID CIDCW and that service is enabled the CID will be updated with the information extracted from the Mini Certificate received from the remote party The Name field of the CID will be prepended with a symbol Both parties can verify the name and number to ensure the identity of the remote party The signing agent is implicit and must be the same for all ATAs that communi...

Page 58: ...inal message to the called party with the following information Message ID 4B Encrypted Master Key 16B or 128b Encrypted Master Salt 16B or 128b The Master Key and Master Salt are encrypted with the public key from the called party mini certificate The Master Key and Master Salt are used by both ends for deriving session keys to encrypt subsequent RTP packets The called party then responds with a ...

Page 59: ...ksys Partner Connection LPC at Linksys com Partners in Europe the Middle East and Africa can find the Mini Certificate Generator on the Firmware and Tools page at linksys itsp com NOTE The partner sites require a logon The Mini Certificate Generator uses the following syntax gen_mc ca key user name user id expire date Where ca key is a text file with the base64 encoded 1024 bit CA private public k...

Page 60: ...zNAAAAAAAMDAwMDAwMDEwMTM00O vJakde2vVMF3Rw4pPXL7lAgIagMpbLSAG2 YlSqt198Cp9rP xMGFfoPmDKGx6JFtkQ5sxLcuwgxpxpxkeXvpZKlYlpsb28L4Rhg5qZA Gqj1hDFCmG6dffZ9SJhxES767G 0JIS N8lQBLr0AuemotknSjjjOy8c 1lTCd2t44Mh0vmwNg4fDck2YdmTMBR516xJt4 uQ LJQlni2kwqlm7scDvll5k232EvvvVtCK0AYa4eWd6fQOpiESCO9CC9aYU1X5lJuU EBZmi3AmcqE9U1LxE OGwopaGyGOh3VyhKgi6JaVtQZt87PiJINKW8XQj3B9Qqe3VgYxWCQNa335YCnDsenASeBxuMIEaBCYd1l1 fVE...

Page 61: ...s SIP Trunking ensures that all calls on a trunk line can be identified by the trunk number and a common caller ID This feature helps you to ensure that calls are directed to available lines and that work groups such as sales teams can work together to answer calls In addition teams can project a common identity when placing outbound calls on a trunk This section provides information about SIP tru...

Page 62: ...n each trunk group with a distinct phone number Each of the eight SPA8000 lines can be configured either as a standalone line as in a classic ATA FXS port or as a trunk line that is associated with a trunk group Inbound calling A trunk group offers a single number for callers to call into the small business with the capability to programmatically ring one or more trunk lines Outbound calling When ...

Page 63: ...ly The Internal Proxy Server handles all SIP signalling between both ends of the call from call establishment to termination RTP Path Whether the line is standalone or a member of a trunk group the Line UA exchanges RTP packets directly with the ITSP equipment NOTE Although the figure shows only one ITSP account in fact each standalone line and each Trunk Group can be configured with a different I...

Page 64: ... on page 67 Inbound Call Routing for a Trunk Group An incoming call is handled as follows 1 When an incoming call is detected by the Trunk UA the UA first checks if there is capacity to handle the call If there is insufficient capacity the UA rejects the call with a 486 response 2 If there is spare call capacity the UA consults the Contact List to determine which line or lines to ring that is for ...

Page 65: ... The hunt order ring interval and maximum duration in the following format hunt algo interval max algo The hunt order re Restart Hunting starts at the beginning of the list If the first line does not answer within the specified interval see below the hunt proceeds through the lines in sequential order ne Next The Trunk UA determines the line that was chosen in the previous hunt and hunting starts ...

Page 66: ...re is no answer after 1 cycle 1 the call is forwarded to forwarded to the specified number cfwd 14085550123 hunt ra 1 cfwd 14085550155 A wildcard character is used to represent all trunk lines The Trunk UA chooses lines in random order hunt ra The interval is meaning the hunt stops when a selected line starts ringing and will ring the line until it answers or the caller hangs up or the line s ring...

Page 67: ...formation specify the call capacity and configure the Contact List Before you begin this procedure determine which lines you want to associate with each trunk group that you are configuring Refer to the following example 1 Connect to the administration web server and choose Admin access with Advanced settings 2 Assign each line to a trunk group as needed a Click Voice tab Ln where n represents the...

Page 68: ...ded See Contact List for a Trunk Group on page 65 e Repeat this step for each trunk group that you need to configure 4 Click Submit All Changes Trunk Group Management You can check the status of the trunks by clicking the Trunk Status link which appears both at the top right corner of the web page and at the lower left corner You also can connect directly to the Trunk Status Page by entering the f...

Page 69: ...nly The hunt includes only the phones that are on hook any state The hunt includes all phones regardless of the state 5 Click Submit All Changes Additional Notes About Trunk Groups This section includes information about other topics that may be of interest when you are configuring trunk groups Voice mail There is no individual mail box for a trunk line For example if lines 1 2 3 and 4 belong the ...

Page 70: ...llowing topics Using the Internal Music Source on page 70 Changing the Music File for the Internal Music Source on page 71 Using the Internal Music Source To use the internal music source simply identify imusic as the MOH server for each IP phone 1 Use the phone menu to find the IP address of the phone a Press the Setup button on the phone keypad b Press 9 Network and then scroll down to 2 Current...

Page 71: ...e local IP address of the computer you are using as the TFTP server port The port number used by the TFTP server default 69 path The location and name of a music file in the correct format For example if the computer local IP address is 192 168 0 5 the directory is named musicdir and the converted music file is named jazzmusic dat then you would enter the following URL tftp 192 168 0 5 69 musicdir...

Page 72: ...t later the FXS port changes to on hook the call is not terminated but continues to stream silence packets to the caller The SAS line can be set up to refresh each streaming audio session periodically using a SIP re INVITE message which detects if the connection to the caller is down If the caller does not respond to the refresh message the SAS line terminates the call so that the streaming resour...

Page 73: ...e and then click the hyperlink in the IP Address column The Telephone Configuration page appears in a separate window c Click the Ext 1 tab d Scroll down to the Call Feature Settings section e In the MOH Server field enter the extension number that you assigned to the FXS port for the streaming audio server f Click Submit All Changes g Close the window for the Telephone Configuration page h Repeat...

Page 74: ...e configured by using the Line page FXO port Line Connect to a standard telephone wall jack for connectivity to the PSTN configured using the PSTN Line page Line 1 does not provide a gateway because it provides only VoIP service The VoIP To PSTN calling function is referred to as a PSTN gateway and the PSTN To VoIP calling function is referred to as a VoIP gateway Note the following definitions Vo...

Page 75: ...caller and SPA Address is a valid address of the SPA3102 or AG310 device such as 10 0 0 100 5061 If the FXO port is currently in use off hook or the PSTN line is being used by another extension the Linksys ATA device replies to the INVITE with a 503 response Otherwise it compares the Dialed Number with the User ID parameter of the PSTN Line If they are the same the Linksys ATA device interprets th...

Page 76: ...r is prompted to enter a PIN number after the Linksys ATA device answers the call The PIN number must end with a key The inter PIN digit timeout is 10 seconds not configurable Up to eight VoIP caller PIN numbers can be configured on the Linksys ATA device A dial plan can be selected for each PIN number If the caller enters a wrong PIN or the Linksys ATA device times out waiting for more PIN digits...

Page 77: ...minated when either call leg is ended When the call terminates the FXO port goes on hook so the PSTN line can be used again The Linksys ATA device detects that the PSTN call leg is ended when one of the following conditions occurs during a call The PSTN Line voltage drops to a very low value this occurs if the line is disconnected from the PSTN service or if the PSTN switch provides a CPC signal A...

Page 78: ...t The default is 480 30 620 30 4 25 25 1 2 Detect Polarity Reversal PSTN Line If yes the Linksys ATA device interprets polarity reversal as a disconnect signal On an inbound PSTN call Linksys ATA device disconnects on the first polarity reversal On an outbound PSTN call Linksys ATA device disconnects on the second polarity reversal because the first polarity reversal indicates the outbound call is...

Page 79: ...he PSTN line is in use when the power is applied to the Linksys ATA device the relay is not flipped until the PSTN line is released This is done so that the Linksys ATA device does not interrupt any call in progress on the PSTN line When Line 1 VoIP service is down because of registration failure or loss of network link the Linksys ATA device can be configured to automatically route all outbound c...

Page 80: ...because it is the only line registered with the service provider Line 1 can have the call forwarded to the PSTN Line after a few seconds using the Call Forward On No Answer feature with gw0 as the forward destination Similarly Line 1 can apply Call Forward All Call Forward On Busy and Call Forward Selective feature and direct the caller to the PSTN Gateway Only PIN authentication is allowed when a...

Page 81: ...has configurable call progress tones Call progress tones are generated locally on the ATA so an end user is advised of status such as ringback Parameters for each type of tone for instance a dial tone played back to an end user may include number of frequency components frequency and amplitude of each component cadence information When one VoIP account is shared between the FXS and PSTN Lines the ...

Page 82: ...s disabled the default PSTN dial plan is used Note than the dial plan choice cannot be 0 for a PSTN caller NOTE A PSTN Access List in terms of Caller ID ANI patterns can be configured into the Linksys ATA device to automatically grant access to the PSTN caller without entering the PIN In this case the default PSTN dial plan is also used The same scenario can be implemented using Ring Thru When the...

Page 83: ... entered after the VoIP call leg is connected the Linksys ATA device plays the reorder tone to the VoIP caller and eventually ends the call when the reorder tone times out NOTE If VoIP Caller ID Pattern is specified and the VoIP caller ID does not match any of the given patterns the Linksys ATA device rejects the call with a 403 This rule applies regardless of the authentication method even when t...

Page 84: ... A delay in seconds before auto answering inbound VoIP calls for the FXO account 0 255 The range is The default is 3 Outside Dial Tone Regional Alternative to the Dial Tone It prompts the user to enter an external phone number as opposed to an internal extension It is triggered by a comma encountered in the dial plan The default is 420 19 10 0 1 VoIP Caller ID Pattern PSTN Line A comma separated l...

Page 85: ...method or else the caller is not authenticated NOTE If the PSTN Line is busy at the moment of the forward it does not answer the VoIP call The call forward rule is ignored and Line 1 continues to ring Forward All to the PSTN gateway In this scenario Line 1 is configured with Cfwd All Dest parameter to the PSTN gateway This scenario is the same the previous case except the FXO picks up the Line 1 c...

Page 86: ...or your setup Router tab Status page You can use the Status page to view information about the Router The Status page includes the following sections Product Information section on page 86 System Status section on page 87 Router tab Status page Product Information section NOTE This information applies to the SPA2102 SPA3102 and SPA8000 routers To configure router settings for the PAP2T AG310 RTP30...

Page 87: ...3 00 Elapsed Time Total time elapsed since the last reboot of the system for example 25 days and 18 12 36 WAN Connection Type The connection type DHCP or Static IP Current IP The current IP address assigned to the ATA device Host Name The current IP address assigned to the ATA device Domain The network domain name of the ATA device Current Netmask The network mask assigned to the ATA device Curren...

Page 88: ... DHCP or DHCP PPPoE tries DHCP then PPPoE Static IP Static IP address of ATA device which takes effect if DHCP is disabled The default is 0 0 0 0 NetMask The NetMask used by ATA device when DHCP is disabled The default is 255 255 255 0 Gateway The default gateway used by ATA device when DHCP is disabled The default is 0 0 0 0 PPPoE Login Name The account name assigned by the ISP for connecting on ...

Page 89: ... the secondary DNS server to take over if problems are discovered with the Primary DNS server NOTE When DHCP is enabled you can enter the IP address of a primary or secondary DNS server in addition to DHCP supplied DNS servers When DHCP is disabled enter the primary and secondary DNS server The default is 0 0 0 0 DNS Service Order The method for selecting the DNS server Manual enter the IP address...

Page 90: ...ess to the administration web server from a computer that is not directly connected to the ATA device Options are Yes or No The default value is Yes WAN Web Server Port The port that is used for WAN access to the ATA device The default value is 80 QOS Policy Enable when you want to use QoS Options are Always On or On when Phone is Use default QOS QDisc Allow QoS Queuing Options are None or TBF tok...

Page 91: ... a passthrough and does not give IP addresses LAN IP Address IP address of the Linksys ATA device on the LAN side LAN Subnet Mask IP address for subnet mask Enable DHCP Server Options are Yes or No for the DHCP Server to provide an IP address DHCP Lease Time Provided by the DHCP Server IP renewal process begins when the time expires DHCP Client Starting IP Address Initial IP address the DHCP Serve...

Page 92: ...g forwards all the ports at the same time to one PC The Port Forwarding feature is more secure because it only opens the ports you want to have opened while DMZ hosting opens all the ports of one computer exposing the computer to the Internet Enable Enable forwarding for the chosen application Options are Yes or No Service Name Any name to call the port forwarding starting port Starting Port The s...

Page 93: ... Used for passing multicast traffic Options are disabled inbound outbound inbound and outbound Starting Port A port identified as a reserve port and that is not used for NAT translation That is if there is a conflict if port forwarding is set on the same port then the port forwarding is cancelled Default is 50000 Num of Ports Reserved Total number of ports reserved Options are 256 512 and 1024 ...

Page 94: ...N User page AG310 and SPA3102 on page 160 NOTE Not all fields listed may be applicable to your ATA device or your setup Info page You can use the Info page to view information about the ATA device With some variations depending on the model this page includes the following sections Product Information section on page 95 System Status section on page 95 Line Status section on page 95 System Informa...

Page 95: ...10 3 2003 16 43 00 Elapsed Time Total time elapsed since the last reboot of the system for example 25 days and 18 12 36 RTP Packets Sent Total number of RTP packets sent including redundant packets RTP Bytes Sent Total number of RTP bytes sent RTP Packets Recv Total number of RTP packets received including redundant packets RTP Bytes Recv Total number of RTP bytes received SIP Messages Sent Total ...

Page 96: ...1 and 2 Decoder Codec used for decoding Call 1 and 2 FAX Status of the fax pass through mode Call 1 and 2 Type Direction of the call May take one of the following values PSTN Gateway Call VoIP To PSTN Call VoIP Gateway Call PSTN To VoIP Call PSTN To Line 1 PSTN call ring through and answered by Line 1 Line 1 Forward to PSTN Gateway VoIP calls Line 1 then forwarded to PSTN GW Line 1 Forward to PSTN...

Page 97: ...s the network domain name of the ATA device Current Netmask Displays the network mask assigned to the ATA device Current Gateway Displays the default router assigned to the ATA device Primary DNS Displays the primary DNS server assigned to the ATA device Secondary DNS Displays the secondary DNS server assigned to the ATA device Field Description PSTN Hook State Hook state of the FXO port Either On...

Page 98: ...nd answered by Line 1 Line 1 Forward to PSTN Gateway VoIP calls Line 1 then forwarded to PSTN GW Line 1 Forward to PSTN Number VoIP calls Line 1 then forwarded to PSTN number Line 1 To PSTN Gateway Line 1 Fallback To PSTN Gateway VoIP State May take one of the following values Idle Collecting PSTN Pin Invalid PSTN PIN PSTN Caller Accepted Connected to PSTN PSTN State May take one of the following ...

Page 99: ...tes sent VoIP Call Bytes Recv Number of bytes received VoIP Call Decode Latency Number of milliseconds for decoder latency VoIP Call Jitter Number of milliseconds for receiver jitter VoIP Call Round Trip Delay Number of milliseconds for delay VoIP Call Packets Lost Number of packets lost VoIP Call Packet Error Number of invalid packets received VoIP Call Mapped RTP Port The port mapped for Real Ti...

Page 100: ...le or disable local access to the administration web server Select yes or no from the drop down menu The default is yes Admin Password Password for the administrator The default is no password User Password Password for the user The default is no password Field Description DHCP Enable or disable DHCP The default is yes Static IP Static IP address of ATA device which takes effect if DHCP is disable...

Page 101: ...system information and critical events If both Debug Server and Syslog Server are specified Syslog messages are also logged to the Debug Server Debug Server The debug server name and port This feature specifies the server for logging ATA device debug information The level of detailed output depends on the debug level parameter setting Debug Level The higher the debug level the more debug informati...

Page 102: ...default is 5 Max Auth Maximum number of times from 0 to 255 a request may be challenged The default is 2 SIP User Agent Name User Agent header used in outbound requests The default is VERSION If empty the header is not included Macro expansion of A to D corresponding to GPP_A to GPP_D allowed SIP Server Name Server header used in responses to inbound responses The default is VERSION SIP Reg User A...

Page 103: ...es of or in the string is escaped with and inside the pair of double quotes Otherwise select no The default is no RFC 2543 Call Hold Configures the type of call hold a sendonly or 0 0 0 0 The default is no do not use the 0 0 0 0 syntax in a HOLD SDP use the a sendonly syntax Mark All AVT Packets If set to yes all AVT tone packets encoded for redundancy have the marker bit set If set to no only the...

Page 104: ...eg Retry Intvl Interval to wait before the ATA device retries registration after failing during the last registration The default is 30 Reg Retry Long Intvl When registration fails with a SIP response code that does not match Retry Reg RSC the ATA device waits for the specified length of time before retrying If this interval is 0 the ATA device stops trying This value should be much larger than th...

Page 105: ...one Try Backup RSC SIP response code that retries a backup server for the current request Retry Reg RSC Interval to wait before the ATA device retries registration after failing during the last registration The default is 30 Field Description RTP Port Min Minimum port number for RTP transmission and reception The RTP Port Min and RTP Port Max parameters should define a range that contains at least...

Page 106: ...fo section of ATA device web page The default is 0 No UDP Checksum Select yes if you want the ATA device to calculate the UDP header checksum for SIP messages Otherwise select no The default is no Stats In BYE Determines whether the ATA device includes the P RTP Stat header or response to a BYE message The header contains the RTP statistics of the current call Select yes or no from the drop down m...

Page 107: ...name used in SDP The default is G729ab G723 Codec Name G 723 codec name used in SDP The default is G723 EncapRTP Codec Name EncapRTP codec name used in SDP The default is EncapRTP Field Description Handle VIA received If you select yes the ATA device processes the received parameter in the VIA header this value is inserted by the server in a response to anyone of its requests If you select no the ...

Page 108: ...y is reported in a Warning header in all subsequent REGISTER requests If the ATA device detects symmetric NAT or a symmetric firewall NAT mapping is disabled The default is no STUN Server IP address or fully qualified domain name of the STUN server to contact for NAT mapping discovery EXT IP External IP address to substitute for the actual IP address of the ATA device in all outgoing SIP messages ...

Page 109: ...art line only for all messages except OPTIONS NOTIFY and REGISTER requests responses full Logs all SIP messages in full text full excl OPT Logs all SIP messages in full text except OPTIONS requests responses full excl NTFY Logs all SIP messages in full text except NOTIFY requests responses full excl REG Logs all SIP messages in full text except REGISTER requests responses full excl OPT NTFY REG Lo...

Page 110: ...ice tab Regional page Call Progress Tones section Field Description Dial Tone Prompts the user to enter a phone number Reorder Tone is played automatically when Dial Tone or any of its alternatives times out The default is 350 19 440 19 10 0 1 2 Second Dial Tone Alternative to the Dial Tone when the user dials a three way call The default is 420 19 520 19 10 0 1 2 Outside Dial Tone Alternative to ...

Page 111: ...rable on the SIP screen The default is 914 16 1371 16 1777 16 20 274 0 1 274 0 2 380 0 3 0 4 0 SIT3 Tone Alternative to the Reorder Tone played when an error occurs as a caller makes an outbound call The RSC to trigger this tone is configurable on the SIP screen The default is 914 16 1371 16 1777 16 20 380 0 1 380 0 2 380 0 3 0 4 0 SIT4 Tone Alternative to the Reorder Tone played when an error occ...

Page 112: ... when a feature is implemented The default is 350 16 1 1 1 This field is not found in the PAP2T Field Description Ring1 Cadence Cadence script for distinctive ring 1 The default is 60 2 4 Ring2 Cadence Cadence script for distinctive ring 2 The default is 60 3 2 1 2 3 4 Ring3 Cadence Cadence script for distinctive ring 3 The default is 60 8 4 8 4 Ring4 Cadence Cadence script for distinctive ring 4 ...

Page 113: ...ence script for distinctive CWT 7 The default is 30 1 1 3 1 1 9 3 CWT8 Cadence Cadence script for distinctive CWT 8 The default is 2 3 3 2 CWT9 Cadence Cadence script for distinctive CWT 9 This field is for the SPA2102 only The default is 30 3 9 7 Field Description Ring1 Name Name in an INVITE s Alert Info Header to pick distinctive ring CWT 1 for the inbound call The default is Bellcore r1 Ring2 ...

Page 114: ...s Bellcore r7 Ring8 Name Name in an INVITE s Alert Info Header to pick distinctive ring CWT 8 for the inbound call The default is Bellcore r8 Ring9 Name Name in an INVITE s Alert Info Header to pick distinctive ring CWT 9 for the inbound call This field is for the SPA2102 only The default is Bellcore r9 Field Description Hook Flash Timer Min Minimum on hook time before off hook qualifies as hook f...

Page 115: ...igits would match other as yet incomplete sequences Range 0 64 seconds The default is 3 CPC Delay Delay in seconds after caller hangs up when the ATA device starts removing the tip and ring voltage to the attached equipment of the called party Range 0 255 seconds ATA device has had polarity reversal feature since release 1 0 which can be applied to both the caller and the callee end This feature i...

Page 116: ...nd call is busy This field is only found in the PAP2T The default is 05 Cfwd All Act Code Forwards all calls to the extension specified after the activation code The default is 72 Cfwd All Deact Code Cancels call forwarding of all calls The default is 73 Cfwd Busy Act Code Forwards busy calls to the extension specified after the activation code The default is 90 Cfwd Busy Deact Code Cancels call f...

Page 117: ...ock CID Per Call Act Code Blocks caller ID on the next outbound call The default is 81 Block CID Per Call Deact Code Removes caller ID blocking on the next inbound call The default is 82 Block ANC Act Code Blocks all anonymous calls The default is 77 Block ANC Deact Code Removes blocking of all anonymous calls The default is 87 DND Act Code Enables the do not disturb feature The default is 78 DND ...

Page 118: ...es Codes These codes tell the ATA device what to do when the user places the current call on hold and is listening to the second dial tone One or more code can be configured into this parameter such as 98 or 97 98 123 etc Max total length is 79 chars This parameter applies when the user places the current call on hold by Hook Flash and is listening to second dial tone Each code and the following v...

Page 119: ...eatures like call forward 72 or BLock Caller ID 67 The codes should not conflict with any of the other vertical service codes internally processed by the ATA device You can empty the corresponding code that you do not want to ATA device to process You can add a parameter to each code in Features Dial Services Codes to indicate what tone to play after the code is entered such as 72 c 67 p Below are...

Page 120: ...02723 Prefer G726r16 Code Makes this codec the preferred codec for the associated call The default is 0172616 Force G726r16 Code Makes this codec the only codec that can be used for the associated call The default is 0272616 Prefer G726r24 Code Makes this codec the preferred codec for the associated call The default is 0172624 Force G726r24 Code Makes this codec the only codec that can be used for...

Page 121: ...mat month day weekday HH mm ss The save time value is the number of hours minutes and or seconds to add to the current time during daylight saving time The save time value can be preceded by a negative sign if subtraction is desired instead of addition The save time value is in this format HH mm ss The month value equals any value in the range 1 12 January December The day value equals any value i...

Page 122: ...DTMF Finland Sweden CID only DTMF sent after polarity reversal and no DTAS and before first ring DTMF Denmark CID only DTMF sentbefore first ring with no polarity reversal and no DTAS ETSI DTMF CID only DTMF sent after DTAS and no polarity reversal and before first ring ETSI DTMF With PR CID only DTMF sent after polarity reversal and DTAS and before first ring ETSI DTMF After Ring CID only DTMF se...

Page 123: ...section on page 133 Gateway Accounts section SPA3102 AG310 section on page 132 Dial Plan section section on page 133 FXS Port Polarity Configuration section section on page 135 In a configuration profile the Line parameters must be appended with the appropriate numeral for example 1 or 2 to identify the line to which the setting applies The number of lines varies with the model of the ATA device F...

Page 124: ...ault is 30 SAS Inbound RTP Sink This setting works around devices that do not play inbound RTP if the streaming audio server line declares itself as a send only device and tells the client not to stream out audio Enter a Fully Qualified Domain Name FQDN or IP address of an RTP sink this value is used by the streaming audio server line in the SDP of its 200 response to an inbound INVITE message fro...

Page 125: ...XY Field Description SIP ToS DiffServ Value TOS DiffServ field value in UDP IP packets carrying a SIP message The default is 0x68 SIP CoS Value 0 7 CoS value for SIP messages The default is 3 RTP ToS DiffServ Value ToS DiffServ field value in UDP IP packets carrying RTP data The default is 0xb8 RTP CoS Value 0 7 CoS value for RTP data The default is 6 Network Jitter Level Determines how jitter buf...

Page 126: ...t no The default is no EXT SIP Port The external SIP port number Auth Resync Reboot If this feature is enabled the ATA device authenticates the sender when it receives the NOTIFY resync reboot RFC 2617 message To use this feature select yes Otherwise select no The default is yes SIP Proxy Require The SIP proxy can support a specific extension or behavior when it sees this header from the user agen...

Page 127: ...IP Port value and the Restrict Source IP feature is enabled the proxy IP address for Lines 1 and 2 is treated as an acceptable IP address for both lines To enable the Restrict Source IP feature select yes Otherwise select no If configured the PAP2T will drop all packets sent to its SIP Ports originated from an untrusted IP address A source IP address is untrusted if it does not match any of the IP...

Page 128: ...ure is disabled the ATA device performs an attended transfer operation by referring the other call leg to the current call leg while maintaining both call legs To use this feature select yes Otherwise select no The default is no MOH Server User ID or URL of the auto answering streaming audio server When only a user ID is specified the current or outbound proxy is contacted Music on hold is disable...

Page 129: ...r parameter is no Range 0 231 1 sec Use DNS SRV Whether to use DNS SRV lookup for Proxy and Outbound Proxy The default is no DNS SRV Auto Prefix If enabled the PAP2T will automatically prepend the Proxy or Outbound Proxy name with _sip _udp when performing a DNS SRV lookup on that name The default is no Proxy Fallback Intvl This parameter sets the delay sec after which the PAP2T will retry from th...

Page 130: ...fault is no Auth ID Authentication ID for SIP authentication Directory Number Enter the number for this line Call Capacity Maximum number of calls allowed on this line interface Choices unlimited 1 2 3 25 Default is 16 Note that the the ATA device does not distinguish between incoming and outgoing calls when talking about call capacity Note unlimited 16 Cfwd No Ans Delay Delay in seconds before th...

Page 131: ...erv Enable Call Return Service The default is yes Call Redial Serv Enable Call Redial Service This field is not found in the PAP2T Call Back Serv Enable Call Back Service Three Way Call Serv Enable Three Way Calling Service Three Way Calling is required for Three Way Conference and Attended Transfer The default is yes Three Way Conf Serv Enable Three Way Conference Service Three Way Conference is ...

Page 132: ...the Referral Services Codes parameter for more details The default is yes Feature Dial Serv Enable Feature Dial Service See the Feature Dial Services Codes parameter for more details The default is yes Service Announcement Serv Enable Service Announcement Service The default is yes Field Description Gateway1 2 3 4 The first of 4 gateways that can be specified to be used in the Dial Plan to facilit...

Page 133: ...ion is as follows Field Description Auto PSTN Fallback If enabled the ATA device automatically routes all calls to the PSTN gateway when the Line 1 proxy is down registration failure or network link down The default is yes Dial Plan Entry Functionality xx Allow arbitrary 2 digit star code 3469 11 Allow x11 sequences 0 Operator 00 Int l Operator 2 9 xxxxxx US local number 1xxx 2 9 xxxxxx US 1 10 di...

Page 134: ...pulver com nat uid jsmith pwd xyz Example 3 39 11 gw0 Enable IP Dialing Enable or disable IP dialing If IP dialing is enabled one can dial user id a b c d port where and are dialed by entering user id must be numeric like a phone number and a b c d must be between 0 and 255 and port must be larger than 255 If port is not given 5060 is used Port and User Id are optional If the user id portion match...

Page 135: ...on on page 136 Subscriber Information section section on page 138 Dial Plan section section on page 139 Proxy and Registration section section on page 145 Voice tab Trunk Group page Line Enable section Field Description Idle Polarity Polarity before a call is connected Forward or Reverse The default is Forward Caller Conn Polarity Polarity after an outbound call is connected Forward or Reverse The...

Page 136: ...To enable the support of 100REL SIP extension for reliable transmission of provisional responses 18x and use of PRACK requests select yes Otherwise select no The default is no Auth Resync Reboot If this feature is enabled the ATA device authenticates the sender when it receives the NOTIFY resync reboot RFC 2617 message To use this feature select yes Otherwise select no The default is yes SIP Proxy...

Page 137: ...rict Source IP If Lines 1 and 2 use the same SIP Port value and the Restrict Source IP feature is enabled the proxy IP address for Lines 1 and 2 is treated as an acceptable IP address for both lines To enable the Restrict Source IP feature select yes Otherwise select no If configured the PAP2T will drop all packets sent to its SIP Ports originated from an untrusted IP address A source IP address i...

Page 138: ...When an incoming call is detected by the Trunk SUA SIP User Agent the SUA first checks if there is capacity to handle the call If not the SUA rejects the call with a 486 response If there is spare capacity the SUA consults the Contact List to determine which lines to ring that is for the proxy to send SIP INVITE to and starts hunting The Contact List specifies the lines the hunt method and other o...

Page 139: ...ll also apply the Trunk Dial Plan on the number before sending out INVITE to the ITSP This Trunk Dial Plan typically is redundant since the trunk should trust the number sent by the Line SUA By default the trunk dial plan allows any non empty number 0 9A D 0 9A D Field Description NAT Mapping Enable To use externally mapped IP addresses and SIP RTP ports in SIP messages select yes Otherwise select...

Page 140: ... PAP2T will renew registration based on this smaller value instead of the configured value If registration failed with an Expires too brief error response the PAP2T will retry with the value given in the Min Expires header in the error response The default is 3600 Ans Call Without Reg Expires value in sec in a REGISTER request The PAP2T will periodically renew registration shortly before the curre...

Page 141: ...way Setup section section on page 149 VoIP Users and Passwords HTTP Authentication section section on page 150 FXO PSTN Timer Values sec section section on page 151 PSTN Disconnect Detection section section on page 153 International Control Settings section section on page 155 Proxy Redundancy Method PAP2T will make an internal list of proxies returned in DNS SRV records In normal mode this list w...

Page 142: ...elect no The default is no NAT Keep Alive Msg Enter the keep alive message that should be sent periodically to maintain the current NAT mapping If the value is NOTIFY a NOTIFY message is sent If the value is REGISTER a REGISTER message without contact is sent Escape sequence of xx is also accepted For example 0d 0a is unescaped into r n CRLF The default is NOTIFY NAT Keep Alive Dest Destination th...

Page 143: ...r reliable transmission of provisional responses 18x and use of PRACK requests select yes Otherwise select no The default is no EXT SIP Port The external SIP port number Auth Resync Reboot If this feature is enabled the ATA device authenticates the sender when it receives the NOTIFY resync reboot RFC 2617 message To use this feature select yes Otherwise select no The default is yes SIP Proxy Requi...

Page 144: ... the same SIP Port value and the Restrict Source IP feature is enabled the proxy IP address for Lines 1 and 2 is treated as an acceptable IP address for both lines To enable the Restrict Source IP feature select yes Otherwise select no If configured the PAP2T will drop all packets sent to its SIP Ports originated from an untrusted IP address A source IP address is untrusted if it does not match an...

Page 145: ...uccessful dynamic registration by the unit If No dial tone will not play unless registration is successful The default is no Register Expires Allow answering inbound calls without successful dynamic registration by the unit If proxy responded to REGISTER with a smaller Expires value the PAP2T will renew registration based on this smaller value instead of the configured value If registration failed...

Page 146: ... parameter is useful only if the primary and backup proxy server list is provided to the PAP2T via DNS SRV record lookup on the server name Using multiple DNS A record per server name does not allow the notion of priority and so all hosts will be considered at the same priority and the PAP2T will not attempt to fall back after a fail over The default is 3600 Proxy Redundancy Method The PAP2T makes...

Page 147: ... select no The default is yes G723 Enable To enable the use of the G723a codec at 6 3 kbps select yes Otherwise select no The default is yes Echo Canc Adapt Enable To enable the echo canceller to adapt select yes Otherwise select no The default is yes G726 16 Enable To enable the use of the G726 codec at 16 kbps select yes Otherwise select no The default is yes Echo Supp Enable To enable the use o...

Page 148: ...3 AVT event 16 INFO uses SIP INFO with the single line signal hf in the message body The MIME type for this message body is taken from the Hook Flash MIME Type setting The default is None FAX Disable ECAN If enabled this feature automatically disables the echo canceller when a fax tone is detected To use this feature select yes Otherwise select no The default is no Release Unused Codec This featur...

Page 149: ...access the PSTN gateway Choose from none PIN HTTP Digest The default is none VoIP PIN Max Retry Number of trials to allow VoIP caller to enter a PIN number used only if authentication method is set to PIN The default is 3 One Stage Dialing Enable one stage dialing applicable if authentication method is none or HTTP Digest or caller is in the Access List The default is yes Line 1 VoIP Caller DP Ind...

Page 150: ...e of 8 PIN numbers that can be specified to control access to the PSTN gateway by a VoIP Caller when the VoIP Caller Authentication Method parameter is set to PIN The default is blank VoIP Caller 1 2 3 4 5 6 7 8 DP Index of the dial plan in the dial plan pool to be associated with the VoIP caller who enters the PIN that matches VoIP Caller 1 2 3 4 5 6 7 8 PIN The default is 1 Field Description VoI...

Page 151: ...oIP User 1 2 3 4 5 6 7 8 DP Index of the dial plan in the dial plan pool to be used with VoIP User 1 The default is 1 VoIP User 1 2 3 4 5 6 7 8 Password The password to be used with VoIP User 1 The user assumes the identity of VoIP User 1 must therefore compute the credentials using this password or the INVITE will be challenged with a 401 response The default is blank Field Description Default Ri...

Page 152: ...s 0 2147483647 The default is 0 PSTN Dialing Delay Delay after hook before the SPA dials a PSTN number The range is 0 255 The default is 1 PSTN Ring Timeout Delay after a ring burst before the SPA decides that PSTN ring has ceased The range is 0 255 The default is 5 PSTN Dial Digit Len Determines the on off time when transmitting digits through the FXO port The syntax is on time off time where on ...

Page 153: ...onnect both call legs when this signal is detected during a gateway call If it is a PSTN gateway call the 1st polarity reversal is ignored and the 2nd one triggers the disconnection For VoIP gateway call the 1st polarity reversal triggers the disconnection The default is yes Detect PSTN Long Silence If enabled SPA will disconnect both call legs when the PSTN side has no voice activity for a durati...

Page 154: ...quency is used for both The tone level value is not used 30 dBm should be used for now Only 1 segment set is allowed Total duration of the segment set is interpreted as the minimum duration of the tone to trigger detection 6 segments of on off time seconds can be specified A 10 margin is used to validated cadence characteristics of the tone The Disconnect Tone Script and Impedance value for variou...

Page 155: ...25 10 10 0 5 0 5 1 Impedance n a Denmark 425 10 10 0 25 0 25 1 Impedance 600 Ring Frequency Min Specify the lower limit of the ring frequency used to detect the ring signal The default is 10 SPA To PSTN Gain dB of digital gain or attenuation if negative to be applied to the signal sent from the SPA to the PSTN side The range is 15 to 12 The default is 0 Ring Frequency Max Specify the higher limit ...

Page 156: ... parameter tags must be appended with 1 or 2 corresponding to line 1 or 2 in the configuration profile It is omitted below for readability Ring Frequency Max Maximum ring frequency to detect The range is 5 100 The default is 100 Ring Validation Time Choose from 100 150 200 256 384 512 640 1024 ms The default is 256ms Ring Indication Delay Choose from 0 512 768 1024 1280 1536 1792 ms The default is...

Page 157: ...r AG310 you can specify the following additional parameters gw0 forward the caller to use the PSTN gateway pstn number gw0 forward to caller to the PSTN number dialed automatically by the SPA through the PSTN gateway The default is blank Cfwd No Ans Delay Delay in sec before Call Forward No Answer triggers Same as Cfwd All Dest The default is 20 Field Description Cfwd Sel1 8 Caller Caller number p...

Page 158: ... 7 8 or 9 The default is blank Field Description CW Setting Call Waiting on off for all calls The default is yes Block CID Setting Block Caller ID on off for all calls The default is no Block ANC Setting Block Anonymous Calls on or off The default is no DND Setting DND on or off The default is no CID Setting Caller ID Generation on or off The default is yes CWCID Setting Call Waiting Caller ID Gen...

Page 159: ...de is determined by the caller Media Loopback Type The loopback type to use when making call to request media loopback operation Choices are Media and Packet Default is Media Note that if the Linksys ATA device answers the call then the loopback type is determined by the caller the Linksys ATA device always picks the first loopback type in the offer if it contains multiple types Field Description ...

Page 160: ...to the ATA device indicating the status of the subscriber s mail box 3 settings are available New VM Available ring as long as there is 1 or more unread voice mail New VM Becomes Available ring when the number of unread voice mail changes from 0 to non zero New VM Arrives ring when the number of unread voice mail increases The default is New VM Available Ring On No New VM If enabled the ATA device...

Page 161: ...on Speed Dial 1 9 The VoIP number to call when the PSTN caller dials a single digit 2 Field Description Ring1 8 Caller Eight PSTN Caller Number Patterns such that the corresponding ring will be used to ring through Line 1 if the PSTN caller matches this pattern Field Description Default Ring The default ring to be used to ring through Line 1 Choose from 1 2 3 4 5 6 7 8 Follow Line 1 If Follow Line...

Page 162: ...m bandwidth type 0 manual or 1 automatic manual_rate Upstream bandwidth rate numerals from 64 to 50000 To enable Manual QoS and specify the upstream bandwidth rate RT_QOS QoS 1 rate_mode 0 manual_rate 5000 RT_QOS To enable Auto QoS RT_QOS QoS 1 rate_mode 1 RT_QOS To disable QoS RT_QOS QoS 0 RT_QOS RTSP RTSP RTSP rtsp_enable RTSP rtsp_enable Real Time Streaming Protocol RTSP 1 enabled or 0 disabled...

Page 163: ...he selected category Application The name of the application Online Games The name of the game MAC Address The MAC address in the format xx xx xx xx xx xx Ethernet Port The port Ethernet Port 1 Ethernet Port 2 Ethernet Port 3 or Ethernet Port 4 priority Priority 0 Low 1 Normal 2 Medium 3 High port_range The port range start end protocol start The first port number in the range end The final port n...

Page 164: ...II characters backslash character not allowed ap_isolation For Internet Only Access Guest Network 1 disabled or 0 enabled ctrl_ssid2 Allows Service Provider to lock SSID2 when enabled user will not be able to configure SSID2 from the device GUI 1 enabled or 0 disabled To enable SSID 2 and specify the SSID name with guest network WL_ BASIC_ SET_2 wl1_net_mode_tmp 1 wl1_ closed 0 wl1_ssid cccddd ap_...

Page 165: ...renewal numerals from 600 to 7200 To enable Wireless WPA Personal specify the keys and set the renewal rate WL_ SECURITY_SET_1 wl_ security_ mode2 wpa_personal wl_ crypto aes wl_wpa_ psk personal wl_wpa_gtk_ rekey 700 WL_ SECURITY_SET_1 To enable Wireless WPA2 Personal specify the keys and set the group key renewal WL_SECURITY_SET_1 wl_ security_mode2 wpa2_personal wl_ crypto aes wl_wpa_psk person...

Page 166: ...he appropriate Quality of Service for the IPTV video transmission towards the et top box in addition to maintaining the appropriate Quality of Service of the Voice Telephony transmission To set the switch rate limit to 40 Mbps and the multicast rate to 40 Mbps SWITCH_RATE mv_switch_total_rate_ limit 5 mv_switch_ingress_mcast_rate 40 SWITCH_RATE WAN Type WAN_TYPE WAN_TYPE wan_proto mode parameters ...

Page 167: ...s ppp_passwd Password enter from 1 to 63 ASCII characters To configure a Telstra Cable connection WAN_TYPE wan_proto heartbeat ppp_username adc ppp_ passwd def hb_ server_ip 192 168 0 16 WAN_TYPE Fail Pattern WAN_TYPE wan_proto dhcpd WAN_TYPE WAN_TYPE wan_proto static wan_ ipaddr 192 168 0 11 wan_netmask 255 255 255 128 WAN_TYPE WAN_TYPE wan_proto l2tp ppp_ passwd def l2tp_server_ip 192 168 0 15 W...

Page 168: ...nable MTU mode 0 automatic or 1 manual wan_mtu MTU size if MTU mode is manual enter a numeral from 576 to 1500 NOTE The default size depends on the Internet Connection Type DHCP or Static IP 1500 PPPoE 1492 PPTP or L2TP 1460 Telstra Cable 1500 To enable MTU in Auto mode WAN_ MTU mtu_enable 0 WAN_MTU To enable MTU in Manual mode and specify the MTU size WAN_MTU mtu_ enable 1 wan_mtu 888 WAN_MTU To ...

Page 169: ...e the requests To forward FTP to 192 168 15 18 SINGLE_PORT_FORWARDING forward_si ngle FTP on tcp 21 21 18 SINGLE_ PORT_FORWARDING To configure port forwarding for a non standard application SINGLE_PORT_ FORWARDING forward_single fw1 on both 1111 2222 28 SINGLE_PORT_ FORWARDING To delete all SINGLE_PORT_FORWARDING SINGLE_PORT_FORWARDING To configure port forwarding for default standard applications...

Page 170: ... RANGE_TRIGGERING PORT_RANGE_TRIGGERING port_ trigger prt2 on 555 666 777 888 PORT_ RANGE_TRIGGERING To delete all PORT_RANGE_TRIGGERING PORT_ RANGE_TRIGGERING VLAN WAN_VLAN WAN_VLAN wan_vlan_enable wan_vla n_id WAN_VLAN wan_vlan_enable VLAN status 1 enabled 0 disabled wan_vlan_id VLAN ID number To enable VLAN and specify the VLAN ID WAN_VLAN wan_vlan_enable 1 wan_vlan_id 123 WAN_VLAN To disable V...

Page 171: ...erface Write it down 6 Press 7932 7 Press 1 to enable WAN access to the administration web server 8 Open the web browser on a networked computer 9 Start Internet Explorer and enter the IP address of the ATA device Q I m trying to access the Linksys ATA administration web server but I do not see the login screen Instead I see a screen saying 404 Forbidden A If you are using Windows Explorer perform...

Page 172: ...on to Full The file output is syslog portnum log for the default port setting syslog 514 log Q How do I access the ATA device if I forget my password A By default the User and Admin accounts have no password If the ITSP set the password for either account and you do not know what it is you need to contact the ITSP If the password for the user account was configured after you received the ATA devic...

Page 173: ...ovided by your firewall Identify the SIP server to which the ATA device is registering if it supports NAT using the Outbound Proxy parameter 4 Add a STUN server to allow traversal of UDP packets through the NAT device On the SIP tab of the administration web server set STUN Enable to yes and enter the IP address of the STUN server in STUN Server STUN Simple Traversal of UDP through NATs is a proto...

Page 174: ...7º to 158ºF 27 to 70ºC Operating Humidity 10 to 90 relative humidity Non Condensing Storage Humidity 10 to 90 relative humidity Non Condensing Device Dimensions 3 98 x 3 98 x 1 10 101 x 101 x 28 mm W x H x D Unit Weight 5 29 oz 0 15kg Power 100 240V 50 60Hz 26 34VA AC Input Certification FCC Part 15 Class B CE ICES 003 Operating Temp 32º to 113º F 0 to 45ºC Storage Temp 13º to 185ºF 25 to 85ºC Ope...

Page 175: ...5 to 85ºC Operating Humidity 10 to 90 relative humidity Non Condensing Storage Humidity 10 to 90 relative humidity Non Condensing Device Dimensions 6 69 x 1 54 x 8 66 170 x 39 x 220 mm Unit Weight 2 85 lbs 1 30kg Power 100 240V 50 60Hz 26 34VA AC Input Certification FCC Part 15 Class B CE ICES 003 A Tick Certification RoH UL Operating Temp 32º to 113º F 0 to 45ºC Storage Temp 13º to 185ºF 25 to 85...

Page 176: ...ative humidity Non Condensing Storage Humidity 5 to 90 relative humidity Non Condensing Device Dimensions 5 51 x 5 51 x 1 06 140 x 140 x 27 mm Unit Weight 10 05 oz 285 g Power External Switching 5VDC 2A Certification FCC Part 15 Class B CE ICES 003 RoHS UL A Tick NZ Telepermit CB Wi Fi 802 11b WPA2 802 11g WPA2 WMM WPS Operating Temp 32º to 104º F 0 to 40ºC Storage Temp 20 C to 60 C 4 F to 140 F O...

Page 177: ...y Non Condensing Storage Humidity 5 to 90 relative humidity Non Condensing Device Dimensions 6 69 x 6 69 x 1 22 170 x 170 x 31 mm Unit Weight 14 39 oz 41 kg Power 12V DC 1 25A Certification FCC Part 15B SubpartB Class B FCC Part 15C SubpartB FCC Part 68 UL60950 UL1950 A Tick UPnP able cert Able CE certification pending Comply to RoHS Operating Temp 32º to 104º F 0 to 40ºC Storage Temp 4º to 158ºF ...

Page 178: ...or electrical stress misuse negligence or accident f the serial number on the Product has been altered defaced or removed or g the product is supplied or licensed for beta evaluation testing or demonstration purposes for which Linksys does not charge a purchase price or license fee ALL SOFTWARE PROVIDED BY LINKSYS WITH THE PRODUCT WHETHER FACTORY LOADED ON THE PRODUCT OR CONTAINED ON MEDIA ACCOMPA...

Page 179: ...t in your area can be found in the product User Guide and at www linksys com Have your product serial number and proof of purchase on hand when calling A DATED PROOF OF ORIGINAL PURCHASE IS REQUIRED TO PROCESS WARRANTY CLAIMS If you are requested to return your product you will be given a Return Materials Authorization RMA number You are responsible for properly packaging and shipping your product...

Page 180: ...nstalled and used according to the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which is found by turning the equipment off and on the user is encouraged to try to correct the interference by one or mor...

Page 181: ...oper disposal and recycling of Linksys products Consumers are required to comply with this notice for all electronic products bearing the following symbol English Environmental Information for Customers in the European Union European Directive 2002 96 EC requires that the equipment bearing this symbol on the product and or its packaging must not be disposed of with unsorted municipal waste The sym...

Page 182: ...af dit gamle udstyr Deutsch German Umweltinformation für Kunden innerhalb der Europäischen Union Die Europäische Richtlinie 2002 96 EC verlangt dass technische Ausrüstung die direkt am Gerät und oder an der Verpackung mit diesem Symbol versehen ist nicht zusammen mit unsortiertem Gemeindeabfall entsorgt werden darf Das Symbol weist darauf hin dass das Produkt von regulärem Haushaltmüll getrennt en...

Page 183: ...ón segura de su aparato usado consulte a las autoridades locales al servicio de recogida y eliminación de residuos de su zona o pregunte en la tienda donde adquirió el producto Français French Informations environnementales pour les clients de l Union européenne La directive européenne 2002 96 CE exige que l équipement sur lequel est apposé ce symbole sur le produit et ou son emballage ne soit pas...

Page 184: ...ghin jipprevjeni konsegwenzi negattivi potenzjali ghall ambjent u ghas sahha tal bniedem Ghal aktar informazzjoni dettaljata dwar ir rimi tat taghmir antik tieghek jekk joghgbok ikkuntattja lill awtoritajiet lokali tieghek is servizzi ghar rimi ta l iskart jew il hanut minn fejn xtrajt il prodott Magyar Hungarian Környezetvédelmi információ az európai uniós vásárlók számára Latviešu valoda Latvian...

Page 185: ...lverwerkingsdienst of met de winkel waar u het product hebt aangeschaft Norsk Norwegian Miljøinformasjon for kunder i EU EU direktiv 2002 96 EF krever at utstyr med følgende symbol avbildet på produktet og eller pakningen ikke må kastes sammen med usortert avfall Symbolet indikerer at dette produktet skal håndteres atskilt fra ordinær avfallsinnsamling for husholdningsavfall Det er ditt ansvar å k...

Page 186: ...vat elektroniikkatuotteet viemällä tuote tai tuotteet viranomaisten määräämään keräyspisteeseen Laitteiston oikea hävittäminen estää mahdolliset kielteiset vaikutukset ympäristöön ja ihmisten terveyteen Lisätietoja vanhan laitteiston oikeasta hävitystavasta saa paikallisilta viranomaisilta jätteenhävityspalvelusta tai siitä myymälästä josta ostit tuotteen Română Romanian Informaţii de mediu pentru...

Page 187: ... avfall Symbolen visar att denna produkt bör kastas efter att den avskiljts från vanligt hushållsavfall Det faller på ditt ansvar att kasta denna och annan elektrisk och elektronisk utrustning på fastställda insamlingsplatser utsedda av regeringen eller lokala myndigheter Korrekt kassering och återvinning skyddar mot eventuella negativa konsekvenser för miljön och personhälsa För mer detaljerad in...

Page 188: ...During Lightning Activity Do not work on the system or connect or disconnect cables during periods of lightning WARNING Installation Instructions Read the installation instructions before connecting the system to the power source WARNING SELV Circuit To avoid electric shock do not connect safety extra low voltage SELV circuits to telephone network voltage TNV circuits LAN ports contain SELV circui...

Page 189: ...nductor or operate the equipment in the absence of a suitably installed ground conductor Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available WARNING Power Supply Installation Warning The power supply must be placed indoors WARNING Circuit Breaker This product relies on the building s installation for short circuit over...

Page 190: ...HE PRODUCT CONTAINING THE SOFTWARE YOU ARE CONSENTING TO BE BOUND BY THE SOFTWARE LICENSE AGREEMENTS BELOW IF YOU DO NOT AGREE TO ALL OF THESE TERMS THEN YOU MAY NOT DOWNLOAD INSTALL OR USE THE SOFTWARE YOU MAY RETURN UNUSED SOFTWARE OR IF THE SOFTWARE IS SUPPLIED AS PART OF ANOTHER PRODUCT THE UNUSED PRODUCT FOR A FULL REFUND UP TO 30 DAYS AFTER ORIGINAL PURCHASE SUBJECT TO THE RETURN PROCESS AND...

Page 191: ...o offer you Upgrades ii to ensure that your Linksys product and or the Software is being used in accordance with the terms of this Agreement iii to provide improvements to the way Linksys delivers technology to you and to other Linksys customers iv to enable Linksys to comply with the terms of any agreements it has with any third parties regarding your Linksys product and or Software and or v to e...

Page 192: ... technical data may be subject to U S export control laws and regulations and or export or import regulations in other countries You agree to comply strictly with all such laws and regulations U S Government Users The Software and documentation qualify as commercial items as defined at 48 C F R 2 101 and 48 C F R 12 212 All Government users acquire the Software and documentation with only those ri...

Page 193: ...the rights that you have You must make sure that they too receive or can get the source code And you must show them these terms so they know their rights We protect your rights with two steps 1 copyright the software and 2 offer you this license which gives you legal permission to copy distribute and or modify the software Also for each author s protection and ours we want to make certain that eve...

Page 194: ...charge to all third parties under the terms of this License c If the modified program normally reads commands interactively when run you must cause it when started running for such interactive use in the most ordinary way to print or display an announcement including an appropriate copyright notice and a notice that there is no warranty or else saying that you provide a warranty and that users may...

Page 195: ...jor components compiler kernel and so on of the operating system on which the executable runs unless that component itself accompanies the executable If distribution of executable or object code is made by offering access to copy from a designated place then offering equivalent access to copy the source code from the same place counts as distribution of the source code even though third parties ar...

Page 196: ...s intended to make thoroughly clear what is believed to be a consequence of the rest of this License 8 If the distribution and or use of the Program is restricted in certain countries either by patents or by copyrighted interfaces the original copyright holder who places the Program under this License may add an explicit geographical distribution limitation excluding those countries so that distri...

Page 197: ...UCH DAMAGES END OF TERMS AND CONDITIONS END OF SCHEDULE 2 Schedule 3 If this Linksys product contains open source software licensed under the OpenSSL license then the license terms below in this Schedule 3 will apply to that open source software The license terms below in this Schedule 3 are from the public web site at http www openssl org source license html ______________________________________...

Page 198: ...IBUTORS BE LIABLE FOR ANY DIRECT INDIRECT INCIDENTAL SPECIAL EXEMPLARY OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES LOSS OF USE DATA OR PROFITS OR BUSINESS INTERRUPTION HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY WHETHER IN CONTRACT STRICT LIABILITY OR TORT INCLUDING NEGLIGENCE OR OTHERWISE ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE EV...

Page 199: ...ines from the library being used are not cryptographic related 4 If you include any Windows specific code or a derivative thereof from the apps directory application code you must include an acknowledgement This product includes software written by Tim Hudson tjh cryptsoft com THIS SOFTWARE IS PROVIDED BY ERIC YOUNG AS IS AND ANY EXPRESS OR IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLI...

Page 200: ...da Contacts 24 Hour Technical Support US Canada 866 606 1866 Mexico 800 314 0939 RMA Return Merchandise Authorization http www linksys com warranty Website http www linksys com FTP Site ftp ftp linksys com Support http www linksys com support Sales Information 800 546 5797 800 LINKSYS Global Contacts Website http www linksys com international Product Registration http www linksys com registration ...

Page 201: ...080815A IH ...