Installation Guide Linear Rotary Motors
ENG
Page 10 / 34
PR02-88
NTI AG / LinMot
4 Installation instructions
4.1 Operating Conditions
•
Maximum ambient temperature limits: -
10 °C…80 °C
•
Internal temperature sensor error occurs at: 90 °C
•
The max. installation altitude is 4'000 m above sea level.
From 1'000 m, derating of 1 °C per 100 m is to be considered for air cooling.
4.2 Installation Options
The PR02 linear motors have a centric fit (technical data in the chapter "Dimensions") on the front so that an
exact alignment of the rotary axis is possible.
The following sketches show examples of different installation options. The detailed mounting dimensions
can be found in the chapter "Dimensions".
4.2.1 Horizontal Installation
The PR02 linear rotary motor can be mounted horizontally using the
T-slots at the bottom.
T-nuts M6 can be used for fastening.
Ordering information
Item
Description
Item-No.
Nut N8/M6
Nut for 8 mm T-slots with M6 thread
0150-2558
4.2.2 Vertical Installation
The T-slots on the underside of the PR02 are used for stable
vertical mounting (see explanation above). In addition, the front of
the motor should be fixed using the 4 tapped holes. The positions of
the tapped holes can be found in the "Dimensions" section.