5 Connections
5.1 Electrical Connection
Only connect or disconnect the motor connector and sensor cable if no voltage is applied to
the servo drive!
Only original LinMot cables may be used for wiring the motor and sensor! Even assembled
cables may only be manufactured from the original LinMot accessories and must be
checked carefully before commissioning!
Incorrect motor wiring can damage the motor and/or the servo drive!
5.1.1 Motor Cable
Three types of cables are available for the linear rotary motors. The standard motor cable is intended for
stationary installation. The High-Flex cable (suitable for cable tracks) and the robot cable are used for
moving cable applications.
Wiring Linear Rotory Motor
Wiring
torque measuring
shaft
Standard cable
High-flex cable
Robot cable
High-flex cable
Cable type
K15-04/05
KS10-04/05
KR05-04/05
KSS02-08
Min. bending radius
stationary
50 mm
(1.97 in)
50 mm
(1.97 in)
50 mm
(1.97 in)
35 mm
Min. bending radius
moving
Not suitable for
applications with
moving motor
cable
100 mm
(3.94 in)
No torsion
80 mm
(3.15 in)
Max. torsion:
±270° pro 0.5 m
61 mm
Approval
Cable material
acc. UL
UL / CSA 300V
UL / CSA 300V
Cable material acc.
UL
Material wire
insulation
TPE-U
TPE-E
TPE-E
PP
Material cable sheath
PUR
PUR
PUR
PUR
Oil resistance
very good
very good
very good
good
Chemical resistance
(to acids, alkalis,
solvents, hydraulic
fluid)
good
good
good
good
moderate for acids
Outdoor durability
very good
very good
very good
good
Flammability
flame retardant
flame retardant
flame retardant
flame retardant