4.8.1 Determination of the max. possible amount of cont. power dissipation Pv_Max
Example
Motor:
P01-48x360F
T
Water
:
25 °C
➔
Pv
max
= 324 W
•
The coolant temperature must not fall below the ambient temperature, otherwise there
is arisk of condensation.
•
When used and stored in a frost-prone area, corrosion protection (e.g. Clariant) has to
be added.
4.8.2 Determination of water flow Q
Example
Pv:
324 W
ΔT
Water
:
6 °C
➔
Q
Water
= 0.7 l / min
To achieve a very regular cooling of the motor, the max. difference between flow and return
temperature should not exceed 10 ° C.