4.8.3 Determination of water pressure
Δp
Example
Q
Water
:
0.7 l / min
➔
Δp = 1.8 bar
The required water pressure to inject the required water flow depends on the hydraulic resistance of the
cooling circuit.
4.8.4 Corrosion protection
It is advised to add a corrosion protection into the cooling medium (water). A suitable agent can be, for
example, Protectogen C Aqua by Clariant. Information of the mixing ratio between the cooling medium and
the corrosion protection agent can be taken from the manufacturer's instructions.
•
Mixing of various corrosion protection agents is to be avoided.
•
Corrosion protection products must be matched to the materials of the cooling circuit.
•
The cooling system consists of copper tubing.
4.8.5 Cooling line connection
Internal thread M5 x 5
Port cross section-Ø D = 3 mm
Two threaded connections are used for the inflow and outflow of the cooling medium to and from the stator
(see illustration above). The connection can be implemented as an M5 thread.