Installation Guide Linear Motors
ENG
Page 16 / 47
P01-48-HP EX protected
NTI AG / LinMot
Artikel
Beschreibung
Art-Nr.
PB01-48x25-80-E-SSC
Bearing for PS01-48x...-SSC (Stainless)
0150-4190
PB03-48x25-80-E-SSC
Bearing for PS01-48x...-SSC (Stainless)
0150-4191
3.5 Performance characteristic
With the design software "LinMot Designer" software (download from the link
https://linmot.com/download/linmot-designer/
), the key data corresponding to the required load situation,
such as peak force, nominal force, or maximum speed, can be calculated and presented. The motor
operating temperature can also be determined. This must be verified in the real application.
3.6 Thermal behavior
3.6.1 Internal temperature monitoring
Setting the motor internal temperature monitoring:
Operation in temperature class T4
The temperature monitoring configuration can be left in the default settings.
The nominal sensor operating temperature is 90°C. At 95 °C a warning is given and at 100 °C the drive goes
into error state. The LinMot-Designer program provides concrete information on the motion designs.
Logging in is necessary to view these parameters.
•
User-ID: «SERVICE»
•
Password: without (in default state)
T4 Max. Sensor Temperature (Default Setting)
Summary of Contents for 0150-4370
Page 42: ...Installation Guide Linear Motors ENG Page 42 47 P01 48 HP EX protected NTI AG LinMot ...
Page 43: ...Installation Guide Linear Motors ENG NTI AG LinMot P01 48 HP EX protected Page 43 47 ...
Page 44: ...Installation Guide Linear Motors ENG Page 44 47 P01 48 HP EX protected NTI AG LinMot ...
Page 46: ...Installation Guide Linear Motors ENG Page 46 47 P01 48 HP EX protected NTI AG LinMot ...