LinMot Linear-Rotary Motors
Connector assignment
Connector assignment Linear Motors
Stecker Typ
C-Connector
Pin
Phase 1+
A
Phase 1-
B
Phase 2+
C
Phase 2-
D
+5V
E
GROand*
F
Sensor Sinus
G
Sensor Cosinus
H
Temp. Sensor
L
Shield*
Casing
Connector assignment Rotary Motors
Stecker Typ
C-Connector
R-Connector
Pin
Pin
Phase A
A
1
Phase B
B
2
Phase C
C
3
NC
D
4
+5V
E
A
GROUND*
F
B
Sensor Sinus
G
C
Sensor Cosinus
H
D
Temp. Sensor
L
E
Schirm*
Gehäuse
Gehäuse
Extension cables are double shielded. The two shields of the extension cables must not be connected together:
The inner shield of the extension cables is used as GROand and must be connected to GROand*, only the outer
shield must be connected to SHIELD* of the connectors.
Caution:
Do not connect or disconnect motor when there is power on the controller.
Double-check each connection!
Wrong connections can destroy controller and stator!