6
Selecting the correct voltage
The LK240 is factory-set for a 230 volts mains supply and must not
be connected to a mains supply before it is adjusted for your local
voltage. To do this, slide the red voltage switch at the back of the
unit until the appropriate voltage is displayed.
Fitting the fuse
The LK240 will come with a fuse fitted corresponding to the factory
set voltage. We recommend that you check the correct fuse has
been fitted.
To fit the fuse, first identify the correct fuse for your local voltage.
This should be:
• a 3.15A anti-surge for 230V
• a 6.3A anti-surge for 115V
• a 6.3A anti-surge for 100V (Japanese version).
Pull open the fuse drawer at the left-hand side of the mains inlet,
insert the fuse in the rear compartment, and close the drawer.
Earthing the LK240
The earthed moulded mains lead supplied must always be used
with the LK240. Never use an unearthed plug or adaptor.
Important note for UK use
The wires in this mains lead use the following colour code:
• Green and yellow Earth
• Blue
Neutral
• Brown
Live