19
Interval (ms)
area to public network. The range is 10-65535milliseconds.
Note:
data will be sent out when real serial data size reaches the preset
packet size, even thoughit's within the serial frame interval.
LoRaWAN Version
Port
Send or receive RS232 data from this port, this port should different from
the Application port.
Range:
2-84,86-223.
Cellular Version
Protocol
Select "TCP" or "UDP" protocol.
Keep Alive Interval
(s)
For TCP connection, the device will send heartbeat packet regularlyto keep
alive. Default: 60s, Range: 60-7200s
Reconnect Interval
(s)
After connection failure, the device will reconnect to the TCP server after
the preset interval. Default:10 s, Range: 10-60s.
Register String
After TCP/UDP connection established, the device will send the register
string to identify the device. The max length is 32 characters.
Server Address
Fill in the TCP or UDP server address (IP/domain name).
Server Port
Fill in the TCP or UDP server port. Range: 1-65535.
Note:
The server address and port should not exactly the same as the
TCP/UDP settings on “Application Mode”.
Status
Show the connection status between the device and the TCP server.
4.3.6 Analog/PT100Settings
IOT-C300-LORA
has two 4-20mAanalog inputs, two 0-10Vanalog inputs and two PT100 inputs
for analog device connection. After wirings, you can click “Fetch” to check if the value is correct.
PT100 Note:
1) The temperature unit in the reporting package is fixed as °C.
2) Please modify the command IF condition threshold settings if you change the temperature
unit.