IOT-S500SWL
IOT-S500UDL-W050
6.3 Downlink Commands
IOT-S500 sensors support downlink commands to configure the device. Application port is 85 by
default.
Appendix
Default LoRaWAN Parameters
DevEUI
2
nd
to 11
th
digits of SN
e.g. SN = 61 26 A1 01 84 96 00 41
Then Device EUI = 24E124126A101849
AppEUI
24E124C0002A0001
03
67 (Temperature)
10 01
10 01 => 01 10 = 272
Temp=272*0.1=27.2°C
04
68(Moisture)
71
71=>113
Hum=113*0.5=56.5%
05
7d
(
Conductivity
)
f0 00
f0 00 => 00 f0 =240 µs/cm
Channel
Type
Data Example
Description
01
75(Battery Level)
64
64=>100
Battery level =100%
03
77 (Water Level)
02 00
02 00=>00 02=2cm
Channel
Type
Data Example
Description
01
75(Battery Level)
64
64=>100
Battery level =100%
03
82 (Distance)
1e 00
1e 00=>00 1e=30mm
Channel
Type
Data Example
Description
ff
03(Set Reporting Interval)
b0 04