background image

                                                                                         

Shenzhen Linshang Technology Co., Ltd. 

3/12/2022      Page 1 of 8 

 

 

 

 

 

 

LS233 

Coating Thickness Gauge 

User Manual V2.0 

 

 

 

 

 

 

 

 

 

 

 

 

Please read this manual carefully before using and reserve it for reference. 

 

Summary of Contents for LS233

Page 1: ...Shenzhen Linshang Technology Co Ltd 3 12 2022 Page 1 of 8 LS233 Coating Thickness Gauge User Manual V2 0 Please read this manual carefully before using and reserve it for reference ...

Page 2: ...enient to view the test data Among them the front display uses LCD LCD ensures that the test results are clearly visible under strong light The top display uses OLED OLED ensures normal display in a low temperature environment of 40 C Standards for the product DIN EN ISO 2808 Paints and Varnishes Determination of Film Thickness JJG 818 2005 Verification Regulation of Magnetic and Eddy Current Meas...

Page 3: ... and OLED as display devices simultaneously LCD ensures that the test results are clearly visible under strong light and OLED ensures normal display in a low temperature environment of 40 C 6 The device can identify the ferrous putty as well as the galvanized iron substrate 7 Wear proof ruby probe tip for long term use 8 Dual use probe for both iron and aluminum The gauge can automatically identif...

Page 4: ...nglish Russian Turkish Setting method In the main setting interface short press power button to select Language option long press the button for 3 seconds to confirm the selection short press the button again to select the desired language long press the button for 3 seconds to confirm the selection and return to the main setting interface Setting interface Language selection Measurement modes sel...

Page 5: ... gauge for the first time after inserting new batteries working with different materials or ambient temperature changes Using iron base and aluminum base adjustment plates respectively to carry out zero adjustment We strictly recommend carrying out the reference check on the uncoated original substrate due to the difference of magnetic and conductive properties of the material some measurement dev...

Page 6: ...rd value within 3μm the gauge can be used normally Note After the zero adjustment completed when repeating measurement on the same spot the reading may not always be 0μm since surface roughness dirt scratches etc It might cause variances The operation of the gauge should be correct and proficient otherwise it will lead to instability of the measured values 4 Measurement 1 Use fingers to hold gauge...

Page 7: ...r powering off V Precaution 1 The device must be zero adjusted respectively with the iron base and aluminum base zero adjustment plates Otherwise there may be abnormal identifications of the ferrous putty and galvanized iron substrate 2 Do not slide the probe on the car surface which will result in damage to the paint and the gauge 3 Please keep the car paint surface clean the dust and dirt on the...

Page 8: ...the whole gauge to our company for maintenance 2 Provide users with spare parts and lifelong maintenance services 3 Provide the users with the gauge calibration service 4 Free technical support for long term Manufacturer Shenzhen Linshang Technology Co Ltd Website www linshangtech com Service hotline 86 755 86263411 Email sales21 linshangtech com ...

Reviews: