-3-
2.5 Inspection and maintenance
Ensure that only qualified service personnel inspect the hoist periodically.
Do not attempt repair of a hook by heat treating, bending or attaching anything
by welding. Such procedures will weaken the hook and may cause failure.
CAUTION!
WARNING!
2.6 OTHER
Always consult the manufacturer or your dealer if you plan to use a hoist in an
excessively corrosive environment (salt water, sea air and/or acid, explosive
environment or other corrosive compounds, etc.).
NEVER use a hoist which has been taken out of service until the hoist has been
properly repaired or replaced.
CAUTION!
WARNING!
3. MAIN SPECIFICATION
3.1 Operating conditions
Allowable ambient conditions:
Operation temperature: -10 ° C to +60 ° C
Operation humidity: IOO%RH or less. This product should not be used under water.
Non-asbestos material: Friction discs are made of asbestos free material.
3.2 Technical specifications
Model
PZ-0.75T
PZ-1.5T
PZ-3T
PZ-6T
PZ-9T
Capacity
t
0.75
1.5
3
6
9
Load chain
mm
6x18
8x24
10x30
10x30
10x30
Number of load chain falls
1
1
1
2
3
Height of lift (standard)
m
1.5
1.5
1.5
1.5
1.5
Height lifted with one complete rotation of handle
mm
18.7
16
16.8
8.4
5.6
Effort required to lift rated load
N
147
294
285
340
360
Running test load
kN
9.2
18.4
36.8
73.5
110.3
Dimensions
(mm)
A
160
182
207.5
207.5
207.5
B
100
109
121.5
121.5
121.5
C
133
157
210
253
338
H min
320
365
465
583
690
L
290
290
420
420
420
D
38
48
58
65
85
K
28
36
43
44
54
NET weight
kg
6.6
11.8
19.4
30.6
46
Additional weight per extra metre height of lift
kg
0.81
1.4
2.2
4.4
6.6
0.75t, 1.5t, 3t
6t
9t