background image

1              

lippert.com 

    432-LIPPERT (432-547-7378)   

Rev: 02.21.22

Lippert

 

Liquid  

Propane Sensor

Installation and Owner’s Manual

(For Aftermarket Applications)

CCD-0004544

Table of Contents

Introduction

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

2

Safety

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

2

Parts List

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

3

Resources Required

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

3

Installation

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

3

Install OneControl Application

  . . . . . . . . . . . . . . . . . . . . . . . . . .  

3

Operation

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

4

Pairing OneControl with LP Sensor

  . . . . . . . . . . . . . . . . . . . .  

4

Setting Up Paired LP Sensor in OneControl App

  . . . . . . .  

5

Adjusting Settings in the OneControl App

  . . . . . . . . . . . . . .  

6

Physical Installation of LP Sensor on LP Tank

  . . . . . . . . . .  

7

Lippert

  

Liquid 

Propane Sensor

Installation and 

Owner’s Manual

(For Aftermarket Applications)

Lippert™ Liquid Propane Sensor Kit

Lippert™ Liquid Propane Sensor Kit

Kit #

Kit #

Description

Description

2021130655

Lippert Liquid Propane Sensor

Maintenance

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

8

Alerts

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

8

Checking LP Tank Level

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

8

Cleaning

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

8

Unpairing LP Sensor from OneControl

  . . . . . . . . . . . . . . . . .  

8

Battery Information

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

9

Resources Required

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

9

Troubleshooting

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

10

Notes

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

11

Summary of Contents for 2021130655

Page 1: ...g Up Paired LP Sensor in OneControl App 5 Adjusting Settings in the OneControl App 6 Physical Installation of LP Sensor on LP Tank 7 Lippert Liquid Propane Sensor Installation and Owner s Manual For A...

Page 2: ...emarks of Google Inc Safety Read and fully understand all instructions before installing or operating this product Adhere to all safety labels THE WARNING SYMBOL ABOVE IS A SIGN THAT A PROCEDURE HAS A...

Page 3: ...RESULT FROM EXPOSING LP TANKS TO HEAT FOLLOW ALL LP TANK SAFETY INSTRUCTIONS AND INSTRUCTIONS FOR DISCONNECTING THE LP TANK FROM SERVICE INSPECT THE LP TANK AND GAS APPLIANCES FOR LEAKS Install OneCon...

Page 4: ...eep the smart device near the LP Sensor during pairing procedure The LP Sensor communicates via Bluetooth BT range can vary and be limited by obstructions like an RV s walls or frame NOTE The OneContr...

Page 5: ...pp make sure permission has been granted and the sensor and phone are next to one another Setting Up Paired LP Sensor in OneControl App Once OneControl and the LP Sensor are paired and communicating v...

Page 6: ...e OneControl app adjust the settings 1 Locate the LP Sensor cell in the device library Fig 8 Open the cell from the arrow Fig 8 2 On the LP Sensor s homepage press Settings Fig 9A Fig 9 A 3 In Setting...

Page 7: ...tom of the LP tank Fig 11A with a cloth where the LP Sensor will be magnetically mounted Remove any debris excess paint or rust NOTE Spacers Fig 11B are recommended They provide clearance for the LP S...

Page 8: ...be minimal Make sure as the LP Sensor is used that the area and sensor are routinely wiped off and free of debris caused by travel weather and general use Obstructions could cause issues with BT conne...

Page 9: ...ation CR 2032 battery Small flat head screwdriver Alignment marks Alignment marks 1 Remove LP Sensor from the LP tank and move a safe distance away from the LP tank Resources Required Fig 15 Fig 16 2...

Page 10: ...ynced following the procedure OneControl app is incorrectly reporting fuel levels There is interference between LP tank and smart device Spacers may be added to the bottom of the tank to lift the tank...

Page 11: ...11 lippert com 432 LIPPERT 432 547 7378 Rev 02 21 22 LippertLiquid Propane Sensor Installation and Owner s Manual For Aftermarket Applications CCD 0004544 Notes...

Page 12: ...a complete document only unless Lippert provides explicit consent to distribute individual parts All manual information is subject to change without notice Revised editions will be available for free...