Selecting the Mounting Location
–
Select a suitable location for the installation of the module.
–
The module should be installed to reduce the amount of shading.
–
Modules should be mounted as far away from rooftop obstructions (AC units,
plumbing vents, skylights, etc.) as possible.
–
If solar panels must be installed near rooftop obstructions, try to orient the
modules with broadside facing the obstruction. This orientation will optimize the
high by-pass diodes in shaded conditions.
–
When possible, mount solar panels so that the majority of surfaces can be
oriented south facing if roof is positioned accordingly.
Selecting the Proper Mounting Structure and
Hardware
–
Observe all instructions and safety precautions included with the mounting
system to be used with the module.
–
Do not drill holes in the glass surface of the module. Doing so will void the
warranty.
–
Do not drill additional mounting holes in the module frame. Doing so will void the
warranty.
–
Modules must be securely attached to the mounting structure using four
mounting points for normal installation.
–
Load calculations are the responsibility of the system designer or installer. The
mounting structure and hardware must be made of durable, corrosion-and UV-
resistant materials.
–
Select mounting location such that screw holes on the mounting brackets
attached to the solar panel frame are aligned with the structural framing of the
roof.
Mounting Methods
–
The module mounting structure must be made of durable, corrosion-resistant
and UV- resistant materials. Furrion recommends L Bracket Mounting Kit, Furrion
model number C-FSFP37MW-A02.
–
In regions with heavy snowfall in winter, select the height of the mounting system
so that the lowest edge of the module is not covered by snow for any length
of time. In addition, ensure that the lowest portion of the module is placed high
enough so that it is not shaded by plants or trees or damaged by flying sand.
–
Modules must be securely attached to the mounting structure.
–
Provide adequate ventilation under the modules in conformity to your local
regulations. A minimum distance of 4" (100mm) between the roof plane and the