TME-104P-CSR-LX800-R1V5.doc
Rev 1.5
10 (44)
2.4
Hardware Setup
Caution
Be sure to observe the EMC security measures. Make sure you are
always at the same potential as the module.
Caution
Never connect or disconnect peripherals like HDD's, PCI, and ISA
boards while the board's power supply is connected and switched on!
Use the cable set provided by LiPPERT to connect the Cool SpaceRunner-LX800 to a VGA monitor.
Connect either PS/2 or USB keyboard or mouse, respectively. Use the 44-wire cable to connect the
hard disk. Make sure that the pins match their counterparts correctly and are not twisted! If you plan
to use additional other peripherals, now is the time to connect them, too.
Connect a 5 volt, 2 amps power supply to the power connector and switch the power on.
Note The 2 amps value is the minimum you should have for the standard
peripherals mentioned. If you want to use more and/or others, please plan
your power budget first! The system will not work if there is not enough
supply current for all your devices.
The display shows the BIOS messages. If you want to change the standard BIOS settings, press the
<F1> key to enter the BIOS menu. See chapter 4.1 for setup details.
If you need to load the BIOS default values, they can be automatically loaded at boot time. See at
he end of chapter 4.1, "Trouble Shooting BIOS Settings", about how to do it.
The Cool SpaceRunner-LX800 boots from CD drives, USB floppy, USB stick, or hard disk. Provided
that any of these is connected and contains a valid operating system image, the display then shows
the boot screen of your operating system.
The Cool SpaceRunner-LX800 does not need any cooling measures, neither at standard environment
temperatures from –20 °C … +60 °C nor in the extended range of -40 °C ... +85 °C.