E-3
E-3
TROUBLESHOOTING
TROUBLESHOOTING GUIDE
Observe Safety Guidelines
detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
No wire feed when gun trigger is
pulled. Fan runs, gas flows and
machine has correct open circuit
voltage (33 vcd maximum)
–
weld
output.
Low or no gas flow when gun
trigger is pulled. Wire feed, weld
output and fan operate normally.
POSSIBLE
CAUSE
1. If the wire drive motor is running
make sure that the correct drive
rolls are installed in the machine.
2. Check for clogged cable liner or
contact tip.
3. Check for proper size cable liner
and contact tip.
1. Check gas supply, flow regulator
and gas hoses.
2. Check gun connection to
machine for obstruction or leaky
seals.
RECOMMENDED
COURSE OF ACTION
If all recommended possible areas
of misadjustments have been
checked and the problem persists,
contact your local Liquid Arc
Authorized Field Service Facility.
FEEDING PROBLEMS
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
LOCAL AUTHORIZED
LIQUID ARC
FIELD SERVICE FACILITY
for assistance before you proceed.
CAUTION
GAS FLOW PROBLEMS
Handymig 170i