Version
01.2017
5
OPERATION AND INSTALLATION MANUAL
2.4. CONNECTION TO THE EXTERNAL AIR INTAKE
The smoke exhaust system must be unique to the insert
(Not allowed pipe discharges common to other fireplace).
Fumes discharged is made from the opening situated at the top.
The discharge pipe must be connected to the outside using appropriate tubes and eventual isolation.
It’s necessary to use materials resistant to high temperatures.
2.5. ASSEMBLY OF CLADDING
The fireplace and the parts of the cladding must be attached together
WITHOUT ANY CONTACT WITH STEEL
STRUCTURE
to prevent heat transmission to the coating and allow thermal expansions. Beware of wood
finishes such as beams or shelves, which must be properly insulated.
In particular, the shelves should be placed at a distance upper to 30 cm from the top of the appliance.