67/92
11.7.
Battery
Battery
12V 95 Ah – 800 A Cold Cranking Amps
(replace with same type only)
If battery tension drops below 6V at any point, the control unit will deactivate. Check battery tension regularly
in the control menu section. Recharge or replace weak batteries.
WARNING
Risk of injury from battery acid
Explosion hazard. When charging batteries, oxyhydrogen gas is produced. Battery acid is corrosive.
Keep ignition sources away.
Pay attention to correct polarity.
Wear protective gloves and goggles.
Before welding work on the machine, always disconnect the negative battery pole and the control
electronics as far as possible.
When charging the battery, oxyhydrogen gas is produced. Keep ignition sources away. Pay attention to
correct polarity. Wear personal protective equipment. Observe the manufacturer's safety instructions.
Before welding work on the machine, always disconnect the negative battery pole and the control electronics
as far as possible.