• The installation of the appliance must not obstruct the outlet.
•
After installation, make sure that it is not resting on its power cord.
•
Before plugging the appliance into the mains socket for the first time,
please let the appliance rest for two hours if the appliance was transported
in the upright position, or 24 hours if the appliance was transported in the
horizontal position. This is to allow the refrigerant gas to go back down
into the compressor. Not respecting this waiting period may damage the
compressor
• WARNING: To avoid any risk, due to instability, the appliance must be secured
in accordance with these instructions.
C
limAte
ClAss
Only install the appliance in a location where the room temperature matches the
climate class for which it was designed
(see table below).
The climate class is on the rating plate located on the outside of the appliance.
The table below shows the correct room temperature for each climate class:
Climate class
Room temperature
SN
+10 to +32°C
N
+16 to +32°C
ST
+16 to +38°C
T
+16 to +43°C
Your RDL 145-55b3 refrigerator/freezer is rated “ST”. If the room temperature is
below or above the indicated room temperature, the performance of your refrigerator/
freezer may be affected, and your food may spoil.
s
uffiCient
ventilAtion
•
Make sure that air can always circulate freely around the appliance.
•
For the appliance to run properly, do not obstruct the vents and leave a space of
at least 20 cm above the appliance, 10 cm between the back and the wall and 2
cm on each side.
•
If your appliance is to be installed next to another refrigerator or freezer, make
sure the appliances are not touching each other. This is to prevent condensation
from forming on the outside.
l
evelling
For vibration-free operation, the appliance needs to be in a level
position. To do this, adjust the adjustable feet at the front to properly
level the appliance.