Select the channel no. from the channel level column, and then press ok to save the 

setting. 

h. 

Bell press

 

——

The same function as ON/OFF button.   

2-6    Scene Setting                                                                                                   

Notice: Scene settings are edited on ECP-T04 directly, while page settings are edited by 

programmable software. (Please refer to 2-2-1 Menu Introduction to check the download 

method.)     

The following pages are example of user page.     

2-6-1

Scene editing   

STEP-1

    Open the programmable software. 

STEP-2

    Create a new page and add 6 scene buttons (name as Scene1~5,Scene Off). 

                   

 

Summary of Contents for ECP-T04

Page 1: ...ISO 9001 CERTIFIED www liteputer com tw LITE PUTER ECP T04 EUM C ECP T04 Touch Panel User Manual Lite Puter Enterprise Co Ltd Website www liteputer com tw E mail sales liteputer com tw...

Page 2: ...are Installation 7 1 3 Device Driver Installation 12 CHAPTER 2 PROGRAMMING SOFTWARE INTRODUCTION 15 2 1 Connection between Device and Programming Software 15 2 2 Menu and Interface Introduction 16 2 2...

Page 3: ...e s IR remote control 37 2 3 8 Value Setting 43 2 3 8 1 Add Value 43 2 3 8 2 Value Property 43 2 4 Page Setting 44 2 4 1 Page Setting 43 2 4 2 Built in Function Setting 43 2 5 Button s Advanced Settin...

Page 4: ...ude backlight setting sound setting clock setting digital photo frame and password protection Build in loudspeaker IR remote controller Power consumption is 2W DC 12V external power 1 2 Specification...

Page 5: ...ISO 9001 CERTIFIED www liteputer com tw LITE PUTER ECP T04 EUM C 2 1 3 Port Introduction 1 2 3 4 3 4 Port introduction 1 USB port 3 EDX port 2 LAN port 4 DMX port 1 4 Dimension Back side...

Page 6: ...ISO 9001 CERTIFIED www liteputer com tw LITE PUTER ECP T04 EUM C 3 Front side...

Page 7: ...ISO 9001 CERTIFIED www liteputer com tw LITE PUTER ECP T04 EUM C 4 Wall box...

Page 8: ...ISO 9001 CERTIFIED www liteputer com tw LITE PUTER ECP T04 EUM C 5 1 5 System Diagram...

Page 9: ...1 Feature Page The components in page include button label bar clock picture User can configure them by the software The configurations can be transmitted from PC to ECP T04 by USB LAN Button componen...

Page 10: ...f in 5mins and turn off in 20 mins Voice setting turn on off screen tap sound Schedule setting Preview function Password protection The above function can be link to the buttons on the page 1 2 Progra...

Page 11: ...D www liteputer com tw LITE PUTER ECP T04 EUM C 8 User can select the language from the list STEP 3 After language selection and press Next Press Next again Traditional Chinese Simplified Chinese Japa...

Page 12: ...ISO 9001 CERTIFIED www liteputer com tw LITE PUTER ECP T04 EUM C 9 STEP 4 Press Yes Press Next in the following steps...

Page 13: ...ISO 9001 CERTIFIED www liteputer com tw LITE PUTER ECP T04 EUM C 10...

Page 14: ...9001 CERTIFIED www liteputer com tw LITE PUTER ECP T04 EUM C 11 Press Finish and then installation is completed After installation is ok there are 2 shortcuts on the desktop and all programs separate...

Page 15: ...mmable software installation next step is device driver installation STEP 1 After installing programmable software correctly copy the driver folder in c Program Files Lite Puter ECP T04 Driver to the...

Page 16: ...ISO 9001 CERTIFIED www liteputer com tw LITE PUTER ECP T04 EUM C 13 Select No not this time Press Next...

Page 17: ...ECP T04 USB Driver in Windows Vista 64 bit Windows 7 64 bit Following are the steps to disable driver signature enforcement in 64 bit operating system 1 During boot up press F8 2 In the list of optio...

Page 18: ...tware Introduction 2 1 Connection between Device and Programmable Software When the user opens the programmable software it will display as below Figure 1 Device is unconnected with programmable softw...

Page 19: ...oduction File menu can create open and save a file Create new project Open file Save file Save as file Exit the programming software Component c menu can add button label clock picture and bar Add but...

Page 20: ...Align with top Align with middle Align with bottom Make same size submenu include Make same width Make same height Make same width and height Horizontal Spacing submenu include make horizontal spacing...

Page 21: ...current page Download current time Device Set s setting includes IP setting device description password settting and MAC address setting IP set Device description Password set MAC address set Three l...

Page 22: ...on interface introduction Open file Delete any page Save file Search device s IP Create new page Device setting 2button on interface introduction Add button Add picture Add label Add value Add bar Sce...

Page 23: ...middle Vertical spacing equal Make component align with bottom Check select the page 5 This area illustrates the component s edited effect 2 3 Component button label bar clock picture value Setting P...

Page 24: ...the dimming value The channel no and zone no are depended on the EDX system working with ECP T04 One button Directly recall a preset dimming value for example 50 Label Label is used for description B...

Page 25: ...rface or use the Component c menu to add a button Copy Button Copy the border shape border color background color and Inactive Active color setting of one button to another STEP 1 After adding a butto...

Page 26: ...T04 EUM C 23 STEP 2 Then add another button on the page Now there are two buttons on the page and STEP 3 Select Meeting Room button and right click to select Format Copy STEP 4 Select cmd2 button and...

Page 27: ...ISO 9001 CERTIFIED www liteputer com tw LITE PUTER ECP T04 EUM C 24 Now double click the cmd2 button to check the property change...

Page 28: ...ng STEP 2 Select the Text property from the dialogue box 3 1 4 2 1 Text display when the button on inactive status 2 Text display when the button on active status 3 Align the text position 4 The text...

Page 29: ...nt to choose text s position on the button When the position s chosen it will mark as X STEP 5 Press OK to save the text setting Right click it to key in the text Select the text s font right click an...

Page 30: ...P 6 Double click button again and select images property from the dialogue box STEP 7 Right click any image below STEP 8 Use Image Alignment to choose image s position on the button Please refer to th...

Page 31: ...s unused button set as page link button set as scene recall button set as up down dimmer button set as dimmer button set as on off button set as bell press button After select the function from the li...

Page 32: ...the function setting Position Border Setting STEP 13 Double click button again and select Position Border property from the dialogue box 1 Position and size setting 2 Border setting 3 The button colo...

Page 33: ...eft Top Width Height blank to edit the number For example Left Top set as 0 0 Width Height set as 80 60 and set the button as green when it on the inactive status set the button as blue when it on the...

Page 34: ...e Before the style selection border width must be set as 1 at least For example Set the Border Shape as Oval Border width as 6 and Border Style as Dash STEP 16 Right click the Border Shape Border widt...

Page 35: ...ER ECP T04 EUM C 32 2 3 2 Label Setting 2 3 2 1 Add Label STEP 1 Open the programmable software STEP 2 Press label key on the interface or use the Component c menu to add a Label 2 3 2 2 Label Propert...

Page 36: ...Text property from the dialogue box 1 2 4 3 1 Text display on label 2 Align the text position 3 Background color setting 4 Text color setting Please refer to the STEP 3 STEP 5 of button s text settin...

Page 37: ...refer to the STEP 15 STEP 17 of button s Position Border Setting to finish label s Border Shape include Rectangle Square Oval Circle Rounded Rectangle Rounded Square 2 3 3 Bar Setting 2 3 3 1 Add Bar...

Page 38: ...P T04 EUM C 35 2 3 3 2 Bar Property STEP 1 Double click the bar on the page Dialogue box define bar property 1 Position setting 2 Channel s address Setting from 1 to 512 STEP 2 Press OK to save the se...

Page 39: ...ftware STEP 2 Press clock key on the interface or use the Component c menu to add a clock The clock can only be synchronized with the system time user cannot set the time 2 3 5 Picture Setting 2 3 5 1...

Page 40: ...ition and size setting 2 Inactive picture path picture display when the picture on inactive status 3 Active picture path picture display when the picture on active status 4 make the photo as the same...

Page 41: ...ct text property from the dialogue box STEP 4 Press Ok to save the setting Notice User can change the button Label Bar s position and size directly 2 3 6 Album Setting Album Load the photo to Digital...

Page 42: ...ISO 9001 CERTIFIED www liteputer com tw LITE PUTER ECP T04 EUM C 39 STEP 2 Press It can load 19 photos at most the last one is the size display only STEP 3 Double click any frame to load the photo...

Page 43: ...equence 3 Exit the Album operation 2 3 7 Button Picture s IR remote control Notice Only button and picture components of ECP T04 can accept IR remote control The IR remote control setting of button an...

Page 44: ...STEP 3 Select function property from the dialogue box Button s Key Function setting please refer to step of 2 3 1 STEP 4 For example select button s function as scene and choose the scene 01 of zone...

Page 45: ...corresponding to the FCN key on the IR remote controller Press FCN key on the remote controller ECP T04 will recall the scene 01 of zone 1 STEP 6 Press OK to save the setting Notice The key on the IR...

Page 46: ...remote controller 2 3 8 Value Setting Value add channel s dimming value display from 0 100 2 3 8 1Add value STEP 1 Open the programmable software STEP 2 Press Value key on the interface or use the Co...

Page 47: ...setting 2 channel s DMX address setting From 1 to 512 STEP 2 Press Ok to save the setting 2 4 Page Setting 2 4 1 Page User page Setting STEP 1 Open the programmable software STEP 2 From File menu New...

Page 48: ...ble click the page Page Properties Dialogue Box Give a name to current page Add or clear the background picture of current page Set the page as default page STEP 5 Click the page name blank and change...

Page 49: ...1 CERTIFIED www liteputer com tw LITE PUTER ECP T04 EUM C 46 STEP 6 Press STEP 7 Double click the picture name you want to load Press Clear to cancel the picture selection STEP 8 Press OK to save the...

Page 50: ...logue box The special page can be linked by the button component Built in functions include backlight set voice set clock set schedule set preview and password protection The built in function pages a...

Page 51: ...C 48 STEP 5 Select the function property from the dialogue box STEP 6 Select the Page Link from key function list mark the circle beside Special Page of Page Link column and select Backlight set from...

Page 52: ...page Digital photo frame page Schedule set page STEP 7Press OK to save the setting After downloading the setting to ECP T04 the Backlight set page will show by pressing the button Voice Set STEP 8Add...

Page 53: ...pressing the button The setting of clock set page password protection page and schedule set page please refer to the steps backlight set and voice set 2 5 Button s Advanced Setting Button s advanced...

Page 54: ...sed button set as page link button set as scene recall button set as up down dimmer button set as dimmer button set as on off button set as bell press button a Unused set the Button as unused b Page L...

Page 55: ...Similar to User Page and Special Page on 2 4 2 user can select the pages that link to the buttons By selecting select user can select the pages from the list of Page Link column By selecting user can...

Page 56: ...g the button Select scene from key function list 1 1 the scene s zone and status ON OFF selection The zone can be selected from 1 40 and scene from SC 1 SC 12 and SC OFF d Up Down Increase decrease th...

Page 57: ...the button the channel will be turned on at preset dimming value By releasing the button the channel will be turned off Select Dimmer from key Function list Set the Zone Channel and Dimming Value on C...

Page 58: ...s ON OFF button 2 6 Scene Setting Notice Scene settings are edited on ECP T04 directly while page settings are edited by programmable software Please refer to 2 2 1 Menu Introduction to check the down...

Page 59: ...P T04 EUM C 56 For example define button SC1 STEP 3 Double click the button Scene1 and select the function property from the button property dialogue box Set Key Function as Scene Zone as 01 and Scene...

Page 60: ...EUM C 57 1 The zone no the scene belongs to There are 40 zones for selection Zone1 Zone40 2 Scene no selection SC1 SC12 SC OFF 3 Scene editing 4 Scene copy 5 Scene paste 6 close the scene edit dialog...

Page 61: ...C 512 channels name editing area D channels in scene editing area E scene FADE time F channel s dimming value selection from 0 100 G select all the channels in area D H shift channel s dimming value f...

Page 62: ...l from the 512 channels Method 1 Press Ctrl and click any channel from the 512 channels for example select the following channels channel 1 channel 3 channel 5 channel 7 channel 9 channel 12 channel 1...

Page 63: ...ISO 9001 CERTIFIED www liteputer com tw LITE PUTER ECP T04 EUM C 60 example select channel 1 10 STEP 7 Press to load the selected channels 1 10 into the channels in scene editing area...

Page 64: ...in scene editing area Cancel the selected channels from the channels in scene editing area Cancel all channels from the channels in scene editing area STEP 8 Press Ctrl and click the channel 1 channel...

Page 65: ...s dimming value to 100 STEP 11 Setting the channels in SC1 s fade time from Ramp Rate drop down For example set channel 1 channel 3 channel 5 channel 7 and channel 9 s fade time as 8 seconds Press Ct...

Page 66: ...o save The setting of Scene2 Scene5 Scene Off is the same Editing the name of a channel STEP 13 Select channel 001 or other channel from the 512 channel s name editing Area it will display as figure o...

Page 67: ...UM C 64 STEP 15 Name channel 1 to 10 as CH1 to CH10 separately and it will display as below STEP 16 After setting press OK to save 2 6 2 Scene recall STEP 1 Download edited page to the device and pres...

Page 68: ...2 7 Schedule Setting The Schedule setting is for recall the scenes at certain time STEP 1 Open the programmable software STEP 2 From File menu New project to the New Page STEP 3 Press Button Picture...

Page 69: ...66 The setting of Text Images and Position Border property please refer to the steps of 2 3 1 For example we set a Button as below STEP 5 Download this page to ECP T04 and press this button it will li...

Page 70: ...ge has 5 schedules 10 pages in total 3 Add schedule 4 Edit schedule 5 Cancel schedule 6 Select schedule the schedule can be edited and canceled only after be selected if the schedule s select it will...

Page 71: ...ene executed on the schedule 5 Display the scene no executed on the schedule 6 Select zone no of the scene executed on the schedule 7 Display zone no of the scene executed on the schedule STEP 8 If th...

Page 72: ...e 3 buttons in different size on the page Left and right alignment Hold CTRL and select component Cmd1 Cmd2 and Cmd3 then press or to make those components align with left or right Align with left Ali...

Page 73: ...Align with top Align with bottom Width and height Hold CTRL and select component Cmd1 Cmd2 and Cmd3 then press or to make those components have same width and height Notice If you want to make several...

Page 74: ...ame width Make same width Press to make Cmd1 Cmd2 and Cmd3 has the same width and height The component which was selected at the last time is the standard in our software Horizontal Spacing Equal and...

Page 75: ...ime to device Download current page data to device Download all data to device Download album photo to device Download scene data to device When the ECP T04 connect with programmable software press th...

Page 76: ...ISO 9001 CERTIFIED www liteputer com tw LITE PUTER ECP T04 EUM C 73 STEP 2 Press...

Page 77: ...PUTER ECP T04 EUM C 74 STEP 3 Press search 1 IP address display column 2 column decides whether the device Information column display or not display not display 3 device information column STEP 4 Doub...

Page 78: ...T04 EUM C 75 STEP 5 Press OK to finish the connection between ECP T03 and programmable software 2 Device setting STEP 1 Open the programmable software STEP 2 Press 1 2 3 4 1 IP address setting 2 Devic...

Page 79: ...od repair for free within a year since the distributing date 3 We do not offer door visiting service If the trouble appears in Lite Puter s products please deliver the equipment to local distributors...

Page 80: ...teputer com tw E mail sales liteputer com tw Shanghai Factory Lite Puter Technology Shanghai Co Ltd Address Building B5 No 298 Lane 3509 Hongmei S Road Shanghai China Zip Code 201108 Tel 86 21 5440821...

Reviews: