background image

SAFETY TIPS.

page 1

WARNING

:  To reduce the risk of electrical shock, turn off the electricity to the fan at the main fuse box or circuit 

panel before you begin the fan installation or before servicing the fan or installing accessories.

1.         Read all instructions and safety information carefully before installing your fan and save these instructions.

CAUTION

:  To avoid personal injury, the use of gloves may be necessary while handling fan parts with sharp 

edges.
2.         Make sure all electrical connections comply with Local Codes or Ordinances, the National Electrical Code, 

and ANSI/NFPA 70-1999.  If you are unfamiliar with electrical wiring or if the house/building wires are 
different colors than those referred to in the instructions, please use a qualified electrician.

3.         Make sure you have a location selected for your fan that allows clear space for the blades to rotate, and at 

least seven (7) feet (2.13 meters) of clearance between the floor and the fan blade tips.  The fan should 
be mounted so that the tips of the blades are at least thirty (30) inches (76 centimeters) from walls or 
other upright structures.

4.         The outlet box and ceiling support joist used must be securely mounted, and capable of supporting at 

least 35 pounds (16 kilograms).  The outlet box must be supported directly by the building structure.  
Use only UL listed outlet boxes marked "FOR FAN SUPPORT."

WARNING

:  To reduce the risk of fire, electrical shock, or personal injury, mount to the outlet box marked 

"Acceptable for Fan Support,"  and use the mounting screws provided with the outlet box.  Most outlet boxes 
commonly used for the support of lighting fixtures are not acceptable for fan support and may need to be 
replaced.  Consult a qualified electrician if in doubt.

WARNING

:  To reduce the risk of fire, electrical shock, or personal injury, wire connectors provided with this fan 

are designed to accept only one12 gauge house wire and two lead wires from the fan. If your house wire is larger 
than 12 gauge or there is more than one house wire to connect to the two fan lead wires, consult an electrician 
for the proper size wire connectors to use.

5.         Electrical diagrams are for reference only.  Light kits that are not packed with the fan must be UL listed and 

marked suitable for use with the model fan you are installing.  Switches must be UL general use 
switches.  Refer to the instructions packaged with the light kits and switches for proper assembly.

6.         After installation is complete, check that all connections are absolutely secure.
7.         After making electrical connections, spliced conductors should be turned upward and pushed carefully up 

into the outlet box.  The wires should be spread apart with the grounded conductor and the 
equipment-grounding conductor on opposite sides of the outlet box.

WARNING

:  To reduce the risk of electrical shock, fire and to prevent humming noise do not use this fan with any 

solid state speed control device or control fan speed with a full range dimmer switch.  [Using a full range dimmer 
switch to control fan speed will cause a loud humming noise from fan.] (

Note

: This fan 

is

 suitable for use with 

remote control.)

8.        Do not operate the reverse switch until fan has come to a complete stop.
9.        Do not insert anything between the fan blades while they are rotating.

WARNING

:  To reduce the risk of personal injury, do not bend the blade arms during assembly or after 

installation.  Do not insert objects into the path of the blades.

WARNING

:  To avoid personal injury or damage to the fan and other items, be cautious when working around or 

cleaning the fan.

10.      Do not use water or detergents when cleaning the fan or fan blades. A dry dust cloth or lightly dampened 

cloth will be suitable for most cleaning.

WARNING

:  To reduce the risk of personal injury, use 

only

 parts provided with this fan.  

The use of parts OTHER 

than those provided with this fan will void the warranty.

NOTE

:  The important safety precautions and instructions appearing in the manual are not meant to cover all 

possible conditions and situations that may occur.  It must be understood that common sense and caution are 
necessary factors in the installation and operation of this fan.

Summary of Contents for E-DCF52BNK5C3

Page 1: ...sting Your Fan pg 8 Troubleshooting pg 9 Warranty pg 9 Parts Replacement pg 9 Installation Guide For Models E DCF52BNK5C3 E DCF52FBZ5C3 E DCF52MWW5C3 net weight of fan 15 65 lb 7 1 kg E89519 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE Federal regulations require ceiling fans with light kits manufactured or imported after January 1 2009 to limit total wattage consumed by the light kit to 1...

Page 2: ... or there is more than one house wire to connect to the two fan lead wires consult an electrician for the proper size wire connectors to use 5 Electrical diagrams are for reference only Light kits that are not packed with the fan must be UL listed and marked suitable for use with the model fan you are installing Switches must be UL general use switches Refer to the instructions packaged with the l...

Page 3: ...ventory that all parts have been included 2 Parts Inventory a canopy 1 piece b hanging bracket pre attached to canopy 1 piece c 4in downrod and hanging ball with pin and clip 1 piece d motor housing 1 piece e blade arm 5 pieces f blade 5 pieces g light kit fitter 1 piece h glass shade 3 pieces i hardware packs a b c d e IMPORTANT REMINDER You must use the parts provided with this fan for proper in...

Page 4: ...t box using original screws spring washers and flat washers provided with new or original outlet box If installing on a vaulted ceiling face opening of hanging bracket towards high point of ceiling Arrange electrical wiring around the back of the hanging bracket and away from the hanging bracket opening Note It is very important that you use the proper hardware when installing the hanging bracket ...

Page 5: ...longer downrod B the top of the downrod should be noted as having a set screw hole use this hole when setting the set screw Insert stop pin into top of extended downrod and raise hanging ball Be sure stop pin aligns with slots on the inside of the hanging ball Tighten set screw securely Tip To prepare for threading electrical wires through downrod apply small piece of electrical tape to the ends o...

Page 6: ...tice that 3 of these holes are larger If there are only 3 screws in top of motor housing please proceed to next paragraph If there are 6 screws in top of motor housing remove every other screw and lock washer Thread wiring through canopy Place canopy over yoke aligning larger holes in canopy with the 3 existing screws in top of motor housing Insert the 3 screws and 3 lock washers that had been rem...

Page 7: ...ualified electrician When downrod is secured in place on the hanging bracket electrical wiring can be made as follows Connect BLACK and BLUE wire from fan to BLACK wire from ceiling with wire connector provided Connect WHITE wire from fan to WHITE wire from ceiling with wire connector provided Connect all GROUND GREEN wires together from fan to BARE GREEN wire from ceiling with wire connector prov...

Page 8: ...packs Hold blade arm up to blade and align holes Insert 3 blade attachment screws along with washers with fingers first and then tighten screws securely with a Phillips screwdriver Repeat for the remaining blades Remove blade arm screws and lock washers from fan motor and set aside Then if applicable remove plastic motor locks from underside of motor and discard plastic motor locks save blade arm ...

Page 9: ... set the fan to MEDIUM Third pull will set the fan to LOW Fourth pull will again set the fan to the OFF setting Test lights with the pull chain in the middle If fan and or lights do does not function please refer to Troubleshooting section to solve any issues before contacting Customer Service Turn fan completely off before moving the reverse switch Set reverse switch to recirculate air depending ...

Page 10: ...chaser for indoor use under the following provisions 1 YEAR WARRANTY LITEX INDUSTRIES LTD will replace or repair any fan which has faulty performance due to a defect in material or workmanship Contact Litex Customer Service at 1 800 527 1292 to arrange for return of fan Return fan shipping prepaid to Litex Industries Ltd We will repair or ship you a replacement fan and we will pay the return shipp...