background image

page 7

10. Light Kit Assembly (Optional).

Remove 3 screws and star washers from switch 
housing cap at top of light kit fitter.

If you wish to use your fan WITH the light kit

remove finial, finial plate, hex nut and rubber 
washer from bottom of light kit fitter. 

Save finial, 

finial plate, hex nut and rubber washer for later use.

 

Locate 

BLUE

 and 

WHITE

 wires in the switch 

housing labeled FOR LIGHT KIT CONNECTION. 
Remove and discard cardboard label and plastic 
that hold these 2 wires together.

Connect 

WHITE

 wire from switch housing to 

WHITE

 wire from light kit fitter. Connect 

BLUE

 wire 

from switch housing to 

BLACK

 wire from light kit 

fitter. Be sure molex connections snap together 
securely.

Align holes in switch housing cap with holes in 
switch housing and attach light kit fitter to switch 
housing with 3 screws previously removed. (

Note

The gap on the top edge of the switch housing cap 
must align with the reverse switch on the switch 
housing for proper fit.) Secure all 3 screws with a 
Phillips screwdriver.

["Light Kit Assembly" continued on next page.]

9. Blade Assembly.

WARNING

:  To reduce the risk of serious bodily 

injury, 

DO NOT use power tools to assemble the 

blades. If overtightened, blades may crack and break.

Time Saver: 

Washers for blade screws can be set on 

each blade screw prior to installing blades.

Locate 15 blade attachment screws and washers in 
one of the hardware packs. Hold blade arm up to 
blade and align holes. Insert 3 blade attachment 
screws (along with washers) with fingers first, and 
then tighten screws securely with a Phillips 
screwdriver. Repeat procedure for remaining blades.

Remove blade arm screws and lock washers from 
underside of motor (save blade arm screws and lock 
washers to secure blade arms). Align blade arm holes 
with motor screw holes and attach blade arm with 
lock washers and blade arm screws. Before securing 
screws permanently, repeat this procedure with 
remaining blade arms. Secure all screws.

Note

: Tighten blade arm screws twice a year.

switch housing 

molex connections

light kit fitter

switch housing

cap

blade arm screws

lock washers

motor housing

blade arm

blade

blade attachment  

screws and washers

Summary of Contents for VN52

Page 1: ... 3 Hanging Bracket Installation pg 3 Fan Assembly pgs 4 5 Wiring pg 6 Canopy Assembly pg 6 Blade Assembly pg 7 Light Kit Assembly Optional pgs 7 8 Testing Your Fan pg 9 Troubleshooting pg 10 Parts Replacement pg 10 Warranty pg 10 net weight of fan 17 22 lb 7 81 kg E124404 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE PRINTED IN CHINA ...

Page 2: ... gauge or there is more than one house wire to connect to the two fan lead wires consult an electrician for the proper size wire connectors to use 5 Electrical diagrams are for reference only Light kits that are not packed with the fan must be UL listed and marked suitable for use with the model fan you are installing Switches must be UL general use switches Refer to the instructions packaged with...

Page 3: ...ter 1 piece j glass shade 1 piece k hardware packs page 2 Carefully open the packaging Remove items from Styrofoam inserts Remove motor housing and place on carpet or Styrofoam to avoid damage to finish Do not discard fan carton or Styrofoam inserts should this fan need to be returned for repairs Check against parts inventory that all parts have been included IMPORTANT REMINDER You must use the pa...

Page 4: ...ing Bracket Installation blade edge Turn off circuit breakers to current fixture from breaker panel and be sure operating light switch is turned to the OFF position WARNING Failure to disconnect power supply prior to installation may result in serious injury Remove existing fixture WARNING When using an existing outlet box be sure the outlet box is securely attached to the building structure and c...

Page 5: ... downrod apply a small piece of electrical tape to the ends of the electrical wires this will keep the wires together when threading them through the downrod Loosen yoke set screws and nut at top of motor housing Remove pin and clip from downrod if you have not already done so Slide downrod through canopy Thread electrical wires through downrod and pull extra wire slack from the upper end of the d...

Page 6: ...holes are larger than the rest of them If there are only 3 screws in top of motor housing please proceed to next paragraph If there are 6 screws in top of motor housing remove every other screw and lock washer Thread wiring through canopy Place canopy over yoke aligning larger holes in canopy with the 3 existing screws in top of motor housing Insert the 3 screws and 3 lock washers that had been re...

Page 7: ... to BLACK wire from ceiling with wire connector provided Connect WHITE wire from fan to WHITE wire from ceiling with wire connector provided Connect all GROUND GREEN wires together from fan to BARE GREEN wire from ceiling with wire connector provided If you intend to control the fan light with a separate light switch connect BLUE wire from fan to the BLACK supply from the independent switch Wrap e...

Page 8: ...l 3 screws with a Phillips screwdriver Light Kit Assembly continued on next page 9 Blade Assembly WARNING To reduce the risk of serious bodily injury DO NOT use power tools to assemble the blades If overtightened blades may crack and break Time Saver Washers for blade screws can be set on each blade screw prior to installing blades Locate 15 blade attachment screws and washers in one of the hardwa...

Page 9: ...h hole in finial and secure glass shade to light kit fitter by tightening finial Do NOT overtighten finial as glass may crack or break If you wish to use your fan WITHOUT the light kit remove hex nut and lock washer from threaded rod at top of light kit fitter Unscrew switch housing cap to remove it from the light kit fitter Then gently feed BLACK and WHITE wires from light kit fitter through hole...

Page 10: ...ues before contacting Customer Service Turn fan completely off before moving the reverse switch Set reverse switch to recirculate air depending on the season DOWN position in summer diagram 2 UP position in winter diagram 3 A ceiling fan will allow you to raise your thermostat setting in summer and lower your thermostat setting in winter without feeling a difference in your comfort Important Rever...

Page 11: ...ce or repair any fan which has faulty performance due to a defect in material or workmanship Contact Litex Customer Service at 1 800 527 1292 to arrange for return of fan Return fan shipping prepaid to Litex Industries Ltd We will repair or ship you a replacement fan and we will pay the return shipping cost 5 YEAR WARRANTY LITEX INDUSTRIES LTD will repair or replace at no charge to the original pu...

Reviews: