background image

page 2

• To reduce the risk of death, personal injury or property damage from fire, 

electric shock, falling parts, cuts/abrasions, and other hazards please 

read all warnings and instructions included with and on the fixture box 

and all fixture labels.  

•  Before installing, servicing, or performing routine maintenance upon this 

equipment, follow these general precautions.

•  Commercial installation, service and maintenance of luminaires should 

be performed by a qualified licensed electrician.

•  For Residential installation: If you are unsure about the installation or 

maintenance of the luminaires, consult a qualified licensed electrician 

and check your local electical code.

•  Maintenance of the luminaires should be performed by person(s) 

familiar with the luminaires’ construction and operation and any hazards 

involved.  Regular fixture maintenance programs are recommended.

•   This  fixture  is  intended  to  be  connected  to  a  properly  installed  and 

grounded UL listed junction box.

•  It will occasionally be necessary to clean the outside of the refractor/

lens. Refractor/lens should be washed in a solution of warm water and 

any mild, non-abrasive household detergent, rinsed with clean water and 

wiped dry.  Should optical assembly become dirty on the inside, wipe 

refractor/lens and clean in above manner, replacing damaged gaskets 

as necessary. 

•  DO  NOT  INSTALL  DAMAGED  PRODUCT!    This  luminaire  has  been 

properly packed so that no parts should have been damaged during 

transit. Inspect to confirm.  Any part damaged or broken during or after 

assembly should be replaced.

•  Recycle:  For  information  on  how  to  recycle  LED  electronic  products, 

please visit www.epa.gov.   

•  These instructions do not purport to cover all details or variations 

in equipment nor to provide every possible contingency to meet in 

connection with installation, operation, or maintenance.  Should further 

information be desired or should particular problems arise which are not 

covered sufficiently for the purchaser’s or owner’s purposes, this matter 

should be referred to Acuity Brands Lighting, Inc. 

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW THESE SAFETY INSTRUCTIONS!

 

WARNING 

 

RISK OF ELECTRIC SHOCK

 

CAUTION 

 

RISK OF INJURY

 

CAUTION 

 

RISK OF FIRE

 

CAUTION 

 

RISK OF PRODUCT DAMAGE

 

WARNING 

 

RISK OF BURN

 

►Disconnect or turn off power before installation or servicing.

 

Verify that supply voltage is correct by comparing it with the luminaire 

label information.

 

Make all electrical and grounded connections in accordance with 

the  National  Electrical  Code  (NEC)  and  any  applicable  local  code 

requirements.

 

►All  wiring  connections  should  be  capped  with  UL  approved  wire 

connectors.

 

Wear gloves and safety glasses at all times when removing luminaire 

from carton, installing, servicing or performing maintenance.

 

►Avoid direct eye exposure to the light source while it is on.

 

Keep combustible and other materials that can burn, away from lamp/

lens.

 

►Do not operate in close proximity to persons, combustible materials or 

substances affected by heat.

 

►Never connect components under load.

 

►Do not mount or support these fixtures in a manner that can cut the outer 

jacket or damage wire insulation.

 

►Unless individual product specifications deem otherwise: Never connect 

an LED product directly to a dimmer packs, occupancy sensor, timing 

device, or other related control devices. LED fixtures must be powered 

directly off a switched circuit.

 

►Unless individual product specifications deem otherwise: Do not restrict 

fixture ventilation. Allow for some volume of airspace around the fixture. 

Avoid covering LED fixtures with insulation, foam, or other material that 

will prevent convection or cooling.

 

►Unless individual product specifications deem otherwise: Do not exceed 

fixtures maximum ambient temperature.

 

►Only use fixture in its intended location.

 

►LED  products  are  Polarity  Sensitive.  Ensure  proper  Polarity  before 

installation.

 

►Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal 

grounding equipment must be worn during all installation or servicing 

of unit.

 

►Do not touch individual electrical components as this can cause ESD, 

shorten lamp life, or alter performance.

 

►Some  components  inside  the  fixture  may  not  be  serviceable.  In  the 

unlikely event your unit may require service, stop using the unit 

immediately and contact an ABL representative for assistance.

 

►  Changes  or  modifications  not  expressly  approved  by  Acuity  Brands 

Lighting could void the authority to operate the equipment.

 

►Always  read  the  fixtures  complete  installation  instructions  prior  to 

installation for any additional fixture specific warnings.

 

►Allow lamp/fixture to cool before handling. Do not touch enclosure, lens 

or light source.

 

►Do not exceed maximum wattage marked on luminaire label.

 

Follow all manufacturer’s warnings, recommendations and restrictions 

including but not limited to: driver type, burning position, mounting 

locations/methods, replacement and recycling.

 

►Use only lamps that comply with ANSI standards.

This equipment has been tested and found to comply with the limits for a 

class B digital device, pursuant to part 15 of the FCC Rules. These limits 

are designed to provide reasonable protection against harmful interference 

when  used  in  a  residential  installation.  This  equipment  generates,  uses 

and can radiate radio frequency energy and, if not installed and used in 

accordance with the instructions may cause harmful interference to radio 

communications.  However,  there  is  no  guarantee  that  interference  will 

not occur in a particular installation. If this equipment does cause harmful 

interference to radio or television reception, which can be determined by 

turning the equipment off and on, the user is encouraged to try to correct 

the interference by one or more of the following measures:

•  Reorient or relocate the receiving antenna.

•   Increase the separation between the equipment and receiver.

•  Connect the equipment into an outlet on a circuit different from that to 

which the receiver is connected.

•  Consult the dealer or an experienced radio/TV technician for help.

 5-YEAR LIMITED WARRANTY

Register your warranty on www.lightahome.com/warranty. Your prompt 

product registration confirms your right to the protection available under 

the terms and conditions of your Lithonia Lighting warranty.

Failure to follow any of these instructions could void product warranties.  

For a complete listing of product Terms and Conditions, please visit www.

acuitybrands.com. Acuity Brands Lighting, Inc. assumes no responsibilities 

for claims arising out of improper or careless installation or handling of its 

products.

Summary of Contents for HGX LED 2RH ALO SWW2 120 PIR

Page 1: ...ECIFICATIONS Adjustable Light output High Low DIM 2 600 2 150 Lumens Power requirement 120VAC 60Hz Electrical Load 26 Watts Motion Detection Angle Up to 180 degree Motion Detection Range Up to 40ft 12m at 18 C 65F Motion Detection Mode Test 1 or 5 minute s on time after motion is detected Manual with switch Motion adjustable sensitivity Daylight Sensor adjustable sensitivity Light Color Warm Cool ...

Page 2: ... deem otherwise Never connect an LED product directly to a dimmer packs occupancy sensor timing device or other related control devices LED fixtures must be powered directly off a switched circuit Unless individual product specifications deem otherwise Do not restrict fixture ventilation Allow for some volume of airspace around the fixture Avoid covering LED fixtures with insulation foam or other ...

Page 3: ...other lights at the daylight sensor Turn OFF Power at circuit breaker box CAUTION Do not rely on wall switch alone to turn off power 3 INSTALLING MOUNTING BRACKET Note Center mounting screw and bracket are pre installed on the light fixture for shipping Loosen the center mounting screw E and remove the mounting bracket Install the mounting bracket D to the junction box using two 3 4 6 or 8 or 10 m...

Page 4: ...ht to stay on after motion stops Set MODE dial to 1M minute or 5M minutes CAN THE LIGHTS STILL BE TURNED ON OFF WITH A LIGHT SWITCH At night Lights can be turned on or off manually with a wall switch or circuit breaker in the Manual Override Mode MANUAL OVERRIDE NOTE MODE dial must be set at 1M or 5M to use manual override To disable the motion sensor and keep the light continuously on for the nig...

Page 5: ... from accumulating inside lens 4 BRIGHTNESS LEVEL SETTING Fixture is preset to full brightness indicated by the larger sun icon above the DIM dial If lower brightness is desired set DIM dial to small sun icon 5 LIGHT COLOR SETTING Note Light color is not adjustable for Accent light the adjustment is only for lamp heads Set dial to desired light color CONTROL SETTINGS DAYLIGHT COOL ...

Page 6: ...e mode 2 The sensor may be picking up a heat source like an air vent dryer vent or brightly painted heat reflective surface 3 The sensor may be picking up motion due to gusty wind 1 Follow manual override instructions to reset 2 Reduce sensitivity Lights flash on and off strobing 1 Heat or light from the lamps may be turning the light control on and off 2 Heat being reflected from other objects ma...

Page 7: ...ión de movimiento Model Number s HGX LED 2RH ALO SWW2 120 PIR ESPECIFICACIONES Salida de luz ajustable alta baja DIM atenuación 2 600 2 150 Lumens Requisitos de energía 120VAC 60Hz Carga eléctrica 26 Watts Ángulo de detección de movimiento hasta 180 grados Rango de detección de movimiento hasta 40 ft 12 m a 18 C 65F Modo de detección de movimiento Test prueba encendido durante 1 o 5 minutos a part...

Page 8: ...el montaje Evite cubrir los montajes LED con aislación goma u otro material que evitará la convección o el enfriamiento de la conducción A menos que las especificaciones del producto individual consideren lo contrario no supere la temperatura ambiente máxima para el montaje Use el montaje sólo en la ubicación para la que está diseñado Los productos LED son sensibles a la polaridad Asegure la corre...

Page 9: ...rgía eléctrica de la caja del disyuntor PRECAUCIÓN No dependa solo del interruptor de pared para desconectar la energía eléctrica 3 INSTALACIÓN DEL SOPORTE DE MONTAJE Nota El soporte y el tornillo de montaje central están preinstalados en la luminaria para su envío 6 INSTALACIÓN DE LA LUMINARIA Alinee la luminaria sobre la caja de conexiones y fije en el soporte de montaje ajustando el tornillo de...

Page 10: ...nutos se apaga después de que el movimiento se detiene ESTABLECER EL DIAL DEL SENSOR DE MOVIMIENTO CONFIGURACIÓN DEL SELECTOR DEL SENSOR DE LUZ DIURNA Sensor de luz detecta la cantidad de luz diurna y evita que las luces se activen durante el día Dial ajuste el dial a la posición izquierda para activarlo con más luz y ajuste el dial a la posición derecha para activarlo con menos luz CONFIGURACIÓN ...

Page 11: ...luminosidad Este ajuste se indica con el icono del sol más grande sobre el selector de atenuación DIM Si se desea un brillo más bajo ajuste el selector de atenuación DIM hacia el icono del sol pequeño 5 CONFIGURACIÓN DEL COLOR DE LA LUZ Nota No se puede ajustar el color de la luz para la iluminación central el ajuste es solo para los cabezales de las lámparas Coloque el selector en el color de luz...

Page 12: ...ópica 1 El calor y la luz de las lámparas pueden encender y apagar el control de luz 2 Es posible que el calor reflejado por otros objetos esté afectando el sensor 3 El sensor está en modo de Prueba 4 Las luces controladas por el sensor brillan o se reflejan en la fotocélula 1 Coloque nuevamente los cabezales de la lámpara alejados del sensor 2 Reduzca la sensibilidad 3 Mientras está en modo de PR...

Page 13: ...ent jusqu à 180 degrés Portée de détection de mouvement jusqu à 12 m 40 pi à 18 C 65F Mode de détection de mouvement Test 1 ou 5 minutes d activation après la détection d un mouvement manuel avec interrupteur Mouvement sensibilité réglable Détecteur de lumière du jour sensibilité réglable Couleur de lumière Chaude froide lumière du jour têtes de lampe Operating Temperature 40 C Accent Light output...

Page 14: ... la partie 15 du règlement de la FCC Ces limites ont été établies pour offrir une protection raisonnable contre les interférences nuisibles dans les installations résidentielles Cet appareil génére utilise et peut émettre de l énergie de radio fréquence S il n est pas installé de maniére conforme aux instructions il peut causer des interférence nuisibles aux communications radio Il n est toutefois...

Page 15: ...disjoncteur MISE EN GARDE Ne pas se fier uniquement à l interrupteur mural pour couper l alimentation 3 INSTALLATION DU SUPPORT DE MONTAGE Remarque La vis de fixation centrale et le support sont préinstallés sur le luminaire pour expédition 6 INSTALLATION DU LUMINAIRE Alignez le luminaire au dessus de la boîte de jonction et fixez le au support de montage en serrant la vis de montage centrale E Re...

Page 16: ...arrêt du mouvement REMARQUE Pendant la journée tous les luminaires sont éteints Utilisez la molette du détecteur de lumière du jour pour régler la sensibilité du détecteur de lumière au besoin COMMANDE MANUELLE REMARQUE Le cadran MODE doit être réglé à 1M ou 5M pour utiliser le remplacement manuel Pour désactiver le détecteur de mouvement et maintenir le luminaire allumé en permanence pendant la n...

Page 17: ...l icône du soleil plus grande au dessus de la molette DIM Si vous souhaitez diminuer la luminosité réglez la molette DIM sur la petite icône du soleil 5 RÉGLAGE DE LA COULEUR DE LA LUMIÈRE Remarque La couleur de la lumière n est pas réglable pour un éclairage d accentuation le réglage concerne uniquement les têtes de lampe Réglez la molette sur la couleur de lumière souhaitée RÉGLER LA MOLETTE DE ...

Page 18: ...baisse 4 Le luminaire est raccordé au travers d un gradateur ou d une minuterie 1 2 3 Réduire la sensibilité au mouvement 4 Ne PAS utiliser de gradateur ni de minuterie pour contrôler le luminaire Les lumières restent allumées en permanence 1 Le capteur est en mode de commande manuelle 2 La zone de détection est peut être trop grande 3 Le détecteur peut capter un mouvement en raison d un vent en r...

Reviews: