PGR-3100 Ground-Fault Indication System

TRANSFORMER

ENCLOSURE

SERVICE

ENCLOSURE

ØA

ØB

ØC

1 A

1 A

1 A

AL

AH

BL

BH

CL

CH

120 V

LAMP

TEST

PGR-3100 

GROUND-FAULT 

INDICATION SYSTEM

L

G

NEUTRAL 
GROUNDING 
RESISTOR

NOTES:

1. USE L TERMINALS FOR SYSTEMS UP TO 
240 V. USE H TERMINALS OF SYSTEMS 
ABOVE 240 V AND UP TO 600 V. 

NOTE 1

TRANSFORMER

ENCLOSURE

SERVICE

ENCLOSURE

ØA

ØB

ØC

1 A

1 A

1 A

AL

AH

BL

BH

CL

CH

120 V

LAMP

TEST

PGR-3100 

GROUND-FAULT 

INDICATION SYSTEM

L

G

NEUTRAL 
GROUNDING 
RESISTOR

PT’S

NOTES 1&2

NOTES:

2.  CONTACT FACTORY FOR 
     NGR-MONITOR COMPATIBILITY.

1.  120/

3 OR 240/

3 V PT SECONDARY

NOTE 3

3.  CODES MAY REQUIRE 
     INTERLOCKED DISCONNECT
     SWITCH

FIGURE 4.  Connection Diagram for a Resistance-Grounded System up to 600 V.

FIGURE 5.  Connection Diagram for Resistance-Grounded Systems above 600 V.

Summary of Contents for PGR-3100

Page 1: ...00 832 3873 E mail techline littelfuse com www littelfuse com PGR 3100 Copyright 2018 Littelfuse All rights reserved Document P95 EPI0 00000 PGR 3100 MANUAL GROUND FAULT INDICATION SYSTEM Revision 6 A...

Page 2: ...Page i REV 6 A 060818 PGR 3100 Ground Fault Indication System This page intentionally left blank...

Page 3: ...ed 240 to 600 V System 2 3 Connection Diagram for Ungrounded Systems above 600 V 2 4 Connection Diagram for Resistance Grounded System up to 600 V 3 5 Connection Diagram for a Resistance Grounded Syst...

Page 4: ...Page iii REV 6 A 060818 PGR 3100 Ground Fault Indication System This page intentionally left blank...

Page 5: ...ets the Canadian Electrical Code requirements for ungrounded alternating current systems in accordance with CEC 10 106 2 3 INSTALLATION Outline and panel mounting details are shown in Fig 1 For 208 to...

Page 6: ...MS UPTO 240 V USE H TERMINALS FOR SYSTEMS ABOVE 240 V UPTO 600 V TRANSFORMER ENCLOSURE SERVICE ENCLOSURE A B C 1 A 1 A 1 A AL AH BL BH CL CH L G 120 V LAMP TEST PGR 3100 GROUND FAULT INDICATION SYSTEM...

Page 7: ...BOVE 240 V AND UPTO 600 V NOTE 1 TRANSFORMER ENCLOSURE SERVICE ENCLOSURE A B C 1 A 1 A 1 A AL AH BL BH CL CH 120 V LAMP TEST PGR 3100 GROUND FAULT INDICATION SYSTEM L G NEUTRAL GROUNDING RESISTOR PT S...

Page 8: ...imum LED Threshold 30 Vac minimum Dielectric Strength 2 200 Vac 1 minute Shipping Weight 0 3 kg 0 8 lb Dimensions Height 108 mm 4 3 Weight 88 9 mm 3 5 Depth 54 mm 2 1 Environment Operating Temperature...

Page 9: ...LEASE DATE MANUAL REVISION PRODUCT REVISION REVISION NUMBER ON PRODUCT LABEL June 08 2018 6 A 060818 03 March 09 2012 6 APPENDIX A PGR 3100 REVISION HISTORY MANUAL REVISION HISTORY REVISION 6 A 060818...

Reviews: