8-29
January 24, 2017
Structure Function Principle
CLG835H
Monitoring system
Torque converter oil temp sensor
Precautions
Switch off the electric lock, and replace the tem-
perature sensor until the machine is completely
cooled if necessary. Therein, measured liquid
overflows once the temperature sensor is loos-
ened, which shall be supplemented timely after
the replacement.
The detection of torque converter oil temp
sensor
1. Unplug the connector, through which the rear
frame harness connects to the temperature
sensor;
2. Disassemble the temperature sensor from
the complete machine;
3. Place the temperature probe of temperature
sensor into the liquid (water/ torque converter
oil), and heat the liquid, to evaluate the tem-
perature sensor performance based on the
parameters below.
Temperature
(°C)
Resistance
(
Ω
)
Error±
%
Min value
Max
value
0
33650
8.8
30700
36600
25
10000
7
9304
10700
90
865.5
2.1
847.3
883.7
P18E00027
Summary of Contents for CLG835H
Page 2: ......
Page 4: ...Contents January 24 2017 CLG835H...
Page 6: ...1 2 General Information January 24 2017 CLG835H...
Page 38: ...1 34 Machine Inspection Table January 24 2017 CLG835H...
Page 156: ...3 2 Power Train System January 24 2017 CLG835H...
Page 214: ...3 2 Power Train System January 24 2017 CLG835H...
Page 272: ...3 60 Testing and adjustment January 24 2017 Power Train Test CLG835H...
Page 276: ...4 4 Hydraulic System January 24 2017 CLG835H...
Page 552: ...6 2 Driver s Cab System January 24 2017 CLG835H...
Page 608: ...7 2 Structure January 24 2017 CLG835H...
Page 662: ...8 4 Electrical System January 24 2017 CLG835H...
Page 677: ...8 19 January 24 2017 Structure Function Principle CLG835H Power System P18E00014...